SearcharxivSearch

arXiv subjects

S. Hildebrandt

Publications and source records attributed to S. Hildebrandt.

6 recordsLinked to original sources

PALM-3000: Exoplanet Adaptive Optics for the 5-meter Hale Telescope

We describe and report first results from PALM-3000, the second-generation astronomical adaptive optics facility for the 5.1-m Hale telescope at Palomar Observatory. PALM-3000 has been engineered for high-contrast imaging and emission spectroscopy of brown dwarfs and large planetary mass bodies at near-infrared wavelengths around bright stars, but also supports general natural guide star use to V ~ 17. Using its unique 66 x 66 actuator deformable mirror, PALM-3000 has thus far demonstrated residual wavefront errors of 141 nm RMS under 1 arcsecond seeing conditions. PALM-3000 can provide phase conjugation correction over a 6.4 x 6.4 arcsecond working region at an observing wavelength of 2.2 microns, or full electric field (amplitude and phase) correction over approximately one half of this field. With optimized back-end instrumentation, PALM-3000 is designed to enable as high as 10e-7 contrast at ~1 arc second angular separation, after including post-observation speckle suppression processing. While optimization of the adaptive optics system is ongoing, we have already successfully commissioned five back-end science instruments and begun a major exoplanet characterization survey, Project 1640, with our partners at American Museum of Natural History and Jet Propulsion Laboratory.

astro-ph.IM

Robo-AO: autonomous and replicable laser-adaptive-optics and science system

We have created a new autonomous laser-guide-star adaptive-optics (AO) instrument on the 60-inch (1.5-m) telescope at Palomar Observatory called Robo-AO. The instrument enables diffraction-limited resolution observing in the visible and near-infrared with the ability to observe well over one-hundred targets per night due to its fully robotic operation. Robo- AO is being used for AO surveys of targets numbering in the thousands, rapid AO imaging of transient events and longterm AO monitoring not feasible on large diameter telescope systems. We have taken advantage of cost-effective advances in deformable mirror and laser technology while engineering Robo-AO with the intention of cloning the system for other few-meter class telescopes around the world.

astro-ph.IM

Optimization of Planck/LFI on--board data handling

To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its telemetry bandwith of 35.5 kbps. The data are processed by an onboard pipeline, followed onground by a reversing step. This paper illustrates the LFI scientific onboard processing to fit the allowed datarate. This is a lossy process tuned by using a set of 5 parameters Naver, r1, r2, q, O for each of the 44 LFI detectors. The paper quantifies the level of distortion introduced by the onboard processing, EpsilonQ, as a function of these parameters. It describes the method of optimizing the onboard processing chain. The tuning procedure is based on a optimization algorithm applied to unprocessed and uncompressed raw data provided either by simulations, prelaunch tests or data taken from LFI operating in diagnostic mode. All the needed optimization steps are performed by an automated tool, OCA2, which ends with optimized parameters and produces a set of statistical indicators, among them the compression rate Cr and EpsilonQ. For Planck/LFI the requirements are Cr = 2.4 and EpsilonQ <= 10% of the rms of the instrumental white noise. To speedup the process an analytical model is developed that is able to extract most of the relevant information on EpsilonQ and Cr as a function of the signal statistics and the processing parameters. This model will be of interest for the instrument data analysis. The method was applied during ground tests when the instrument was operating in conditions representative of flight. Optimized parameters were obtained and the performance has been verified, the required data rate of 35.5 Kbps has been achieved while keeping EpsilonQ at a level of 3.8% of white noise rms well within the requirements.

astro-ph.IM

Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.

astro-ph.IM

Planck pre-launch status: the Planck-LFI programme

This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic and extragalactic astrophysics. The instrument design and development are outlined, together with the model philosophy and testing strategy. The instrument is presented in the context of the Planck mission. The LFI approach to ground and inflight calibration is described. We also describe the LFI ground segment. We present the results of a number of tests demonstrating the capability of the LFI data processing centre (DPC) to properly reduce and analyse LFI flight data, from telemetry information to calibrated and cleaned time ordered data, sky maps at each frequency (in temperature and polarization), component emission maps (CMB and diffuse foregrounds), catalogs for various classes of sources (the Early Release Compact Source Catalogue and the Final Compact Source Catalogue). The organization of the LFI consortium is briefly presented as well as the role of the core team in data analysis and scientific exploitation. All tests carried out on the LFI flight model demonstrate the excellent performance of the instrument and its various subunits. The data analysis pipeline has been tested and its main steps verified. In the first three months after launch, the commissioning, calibration, performance, and verification phases will be completed, after which Planck will begin its operational life, in which LFI will have an integral part.

astro-ph.CO

Detection of anomalous microwave emission in the Perseus molecular cloud with the COSMOSOMAS experiment

We present direct evidence for anomalous microwave emission in the Perseus molecular cloud, which shows a clear rising spectrum from 11 to 17 GHz in the data of the COSMOSOMAS experiment. By extending the frequency coverage using WMAP maps convolved with the COSMOSOMAS scanning pattern we reveal a peak flux density of 42 (+/-) 4 Jy at 22 GHz integrated over an extended area of 1.65 x 1.0 deg centered on RA = 55.4 (+/-) 0.1 deg and Dec = 31.8 (+/-) 0.1 deg (J2000). The flux density that we measure at this frequency is nearly an order of magnitude higher than can be explained in terms of normal galactic emission processes (synchrotron, free-free and thermal dust). An extended IRAS dust feature G159.6-18.5 is found near this position and no bright unresolved source which could be an ultracompact HII region or gigahertz peaked source could be found. An adequate fit for the spectral density distribution can be achieved from 10 to 50 GHz by including a very significant contribution from electric dipole emission from small spinning dust grains.

astro-ph