SearcharxivSearch

arXiv subjects

S. I. Sandacci

Publications and source records attributed to S. I. Sandacci.

3 recordsLinked to original sources

Stress-Dependent Magnetoimpedance in Co-Based Amorphous Wires and Application to Tunable Microwave Composites

A remarkably strong dependence of magnetoimpedance (MI) on tensile stress has been observed in the microwave frequency range for thin CoMnSiB glass-coated microwires exposed to a special thermal treatment. The MI ratio runs into more than 100% at 0.5-1.5 GHz when the tensile stress of 600 MPa is applied to the wire. It was demonstrated that a large MI change at such high frequencies is related predominantly with the dc magnetization orientation. A host of such microwires incorporated into a dielectric matrix may constitute a new sensing medium that is characterized by the stress-dependent effective permittivity. Such medium can be used for the microwave visualization of the stress distribution inside of a composite structure or on its surface.

cond-mat.mtrl-sci

Stress effect on magnetoimpedance (MI) in amorphous wires at GHz frequencies and application to stress-tunable microwave composite materials

The effect of tensile stress on magnetoimpedance (MI) in CoMnSiB amorphous wires at microwave frequencies (0.5-3 GHz) is investigated both experimentally and theoretically. In the presence of the dc bias magnetic field of the order of the anisotropy field, the impedance shows very large and sensitive change when the wire is subjected to a tensile stress: 100% and 60% per 180 MPa for frequencies 500 MHz and 2.5 GHz, respectively. It is demonstrated that this behavior owes mainly to the directional change in the equilibrium magnetization caused by the applied stress and field, which agrees well with the theoretical results for the surface impedance. This stress effect on MI is proposed to use for creating microwave stress-tunable composite materials containing short magnetic wires. The analysis of the dielectric response from such materials shows that depending on the stress level in the material, the dispersion of the effective permittivity can be of a resonant or relaxation type with a considerable change in its values (up to 100% at 600 MPa). This media can be used for structural stress monitoring by microwave contrast imaging.

cond-mat.mtrl-sci

Off-diagonal impedance in amorphous wires and application to linear magnetic sensors

The magnetic-field behaviour of the off-diagonal impedance in Co-based amorphous wires is investigated under the condition of sinusoidal (50 MHz) and pulsed (5 ns rising time) current excitations. For comparison, the field characteristics of the diagonal impedance are measured as well. In general, when an alternating current is applied to a magnetic wire the voltage signal is generated not only across the wire but also in the coil mounted on it. These voltages are related with the diagonal and off-diagonal impedances, respectively. It is demonstrated that these impedances have a different behaviour as a function of axial magnetic field: the former is symmetrical and the latter is antisymmetrical with a near linear portion within a certain field interval. In the case of the off-diagonal response, the dc bias current eliminating circular domains is necessary. The pulsed excitation that combines both high and low frequency harmonics produces the off-diagonal voltage response without additional bias current or field. This suits ideal for a practical sensor circuit design. The principles of operation of a linear magnetic sensor based on C-MOS transistor circuit are discussed.

physics.ins-det