Searcharxiv⌕ Search

arXiv subjects

S. J. C. Yates

Publications and source records attributed to S. J. C. Yates.

At least 19 recordsLinked to original sources

Effect of total dose proton irradiation on the performance of Kinetic Inductance Detectors for far-Infrared space observatory

Kinetic Inductance Detectors (KIDs) are a promising technology for future space missions, where exposure to high-energy particles may affect detector performance. In this work, we irradiated two types of KID arrays, absorber coupled and antenna coupled, with high-energy protons at 120 mK. We used a total dose equivalent to approximately 10 years of operation at the L2 Lagrange point. A comparison between pre-irradiation and post-irradiation measurements (24 hours after a 5.7 krad total dose) was done, while keeping the detectors at 120 mK. We find that there is no significant change in the quasi-particle lifetime τ_qp and the dark responsivity dθ/dPdark, but we do observe an increase in the noise and NEP that is tentatively attributed to limitations in the post radiation data analysis.

physics.ins-det↗

AMKID -- a large KID-based camera at the APEX telescope

The thermal emission at sub-millimeter wavelengths carries unique information in many astronomical applications ranging from disks and planet formation around young stars, to galaxy evolution studies at cosmological distances. Advancing on the mapping speed to detect this faint emission in ground-based astronomy has been a technical challenge for decades. The APEX Microwave Kinetic Inductance Detector (AMKID) camera was designed to accomplish this task. The instrument is a wide field-of-view camera based on kinetic inductance detectors. It is installed on the 12~meter APEX telescope in Chile at 5.100~meters above see level. The instrument operates dual color, covering simultaneously the 350~GHz and 850~GHz atmospheric windows. It has a large field-of-view of 15.3'x15.3', and an unprecedented number of pixels: 13.952~detectors in the high frequency band and 3.520~detectors in the low frequency band. Here we present a complete description of the instrument design and construction together with results of the successful low frequency array (LFA) commissioning campaign executed during the last year. The LFA performance is in good agreement with design parameters, with detector sensitivity of 2.2~mK$\sqrt{s}$ and diffraction limited beam sizes of 17.0''. On-sky measurements demonstrate a sensitivity of 70-90~mJy$\sqrt{s}$ per detector when operating under good atmospheric conditions (PWV below 1.0mm). With this performance the LFA regularly achieve a mapping sensitivity of 25~mJy when mapping a square degree in an hour. AMKID on APEX with its dual color observing capabilities, high sensitivity, large field-of-view and high angular resolution holds the promise to open a new range of science with the APEX telescope.

astro-ph.IM↗

DESHIMA 2.0: A 200-400 GHz Ultra-wideband Integrated Superconducting Spectrometer

DESHIMA (Deep Spectroscopic HIgh-redshift MApper) is a broadband integrated superconducting spectrometer (ISS) for millimeter (mm) / sub-millimeter (sub-mm) wave astronomy based on Kinetic Inductance Detectors (KIDs). This paper describes characterization of DESHIMA 2.0 in laboratory settings. The instrument features NbTiN superconducting microstrip (MS) filters with low-loss a-SiC:H dielectric and an ultra-wideband leaky-wave antenna. A laboratory setup was designed, incorporating the cryostat housing cryogenic optics and ISS chip comprising 339 KIDs connected to MS filters tuned for (sub-)mm wave frequencies. Room-temperature mirrors on a hexapod stage allowed precise positioning and alignment of optical elements. The sky-position chopper was positioned on a motor-controlled stage for fine-tuned control over its position and alignment. Thanks to the multiplexing capability of KIDs, we could simultaneously measure multiple performance metrics across the entire frequency range. We showed that DESHIMA 2.0 achieved significant improvements in performance compared to its predecessor (DESHIMA 1.0): measured instantaneous frequency coverage was 200$-$400 GHz with a mean filter $Q_{filter}$ of $340 \pm 50$; instrument efficiency reached $\sim8$ \%, indicating 4 times wider band coverage and 4 times higher sensitivity. The yield rate for MS filters exceeded 98 \%. The estimated aperture efficiency from measured beam patterns agreed well with the designed value of approximately 70 \%. The telescope far-field beam patterns calculated from measured beam patterns also exhibited good agreement with design specifications. We also demonstrated validity of a new method of absolute frequency calibration using the data from beam pattern measurement.

astro-ph.IM↗

Alignment and optical verification of DESHIMA 2.0 at ASTE

We developed, characterized, and verified an alignment procedure for the DESHIMA 2.0 instrument, an ultra wide-band spectrometer operating between 200--400 GHz, at the ASTE telescope. To this end, we mounted the warm optics, consisting of a modified Dragonian dual reflector system, on a motor controlled hexapod. Crucial in the alignment procedure is our sky chopper, which allows fast beam switching. It has a small entrance and exit aperture coupling to (cold) sky, which creates a measurable signal with respect to the warm cabin environment. By scanning the instrument beam across the entrance aperture of the sky chopper using the hexapod, we found the hexapod configuration that produced the lowest signal on our detectors, implying the beam is coupled fully to cold sky and not the warm cabin. We first characterized the alignment procedure in the laboratory, where we used a vat containing liquid nitrogen as the cold source behind the sky chopper. Then, we applied the alignment procedure to DESHIMA 2.0 at ASTE. We found that the alignment procedure significantly improved the aperture efficiency compared to previously reported values of the aperture efficiency of DESHIMA at ASTE, which indicates the veracity of the alignment procedure.

astro-ph.IM↗

Optimisation-based alignment of wideband integrated superconducting spectrometers for sub-mm astronomy

Integrated superconducting spectrometers (ISSs) for wideband sub-mm astronomy utilise quasi-optical systems for coupling radiation from the telescope to the instrument. Misalignment in these systems is detrimental to the system performance. The common method of using an optical laser to align the quasi-optical components requires accurate alignment of the laser to the sub-mm beam coming from the instrument, which is not always guaranteed to a sufficient accuracy. We develop an alignment strategy for wideband ISSs directly utilising the sub-mm beam of the wideband ISS. The strategy should be applicable in both telescope and laboratory environments. Moreover, the strategy should deliver similar quality of the alignment across the spectral range of the wideband ISS. We measure misalignment in a quasi-optical system operating at sub-mm wavelengths using a novel phase and amplitude measurement scheme, capable of simultaneously measuring the complex beam patterns of a direct-detecting ISS across a harmonic range of frequencies. The direct detection nature of the MKID detectors in our device-under-test, DESHIMA 2.0, necessitates the use of this measurement scheme. Using geometrical optics, the measured misalignment, a mechanical hexapod, and an optimisation algorithm, we follow a numerical approach to optimise the positioning of corrective optics with respect to a given cost function. Laboratory measurements of the complex beam patterns are taken across a harmonic range between 205 and 391 GHz and simulated through a model of the ASTE telescope in order to assess the performance of the optimisation at the ASTE telescope. Laboratory measurements show that the optimised optical setup corrects for tilts and offsets of the sub-mm beam. Moreover, we find that the simulated telescope aperture efficiency is increased across the frequency range of the ISS after the optimisation.

astro-ph.IM↗

Complex beam mapping and Fourier optics analysis of a wide field Microwave Kinetic Inductance Detector camera

For astronomical instruments, accurate knowledge of the optical pointing and coupling are essential to characterize the alignment and performance of (sub-)systems prior to integration and deployment. Ideally, this requires the phase response of the optical system, which for direct (phase insensitive) detectors was not previously accessible. Here we show development of the phase sensitive complex beam pattern technique using a dual optical source heterodyne technique for a large field of view Microwave Kinetic Inductance Detector camera at 350 GHz. We show here how you can analyze the measured data with Fourier optics, which allows integration into a telescope model to calculate the on sky beam pattern and telescope aperture efficiency prior to deployment at a telescope.

astro-ph.IM↗

A kilo-pixel imaging system for future space based far-infrared observatories using microwave kinetic inductance detectors

Future astrophysics and cosmic microwave background space missions operating in the far-infrared to millimetre part of the spectrum will require very large arrays of ultra-sensitive detectors in combination with high multiplexing factors and efficient low-noise and low-power readout systems. We have developed a demonstrator system suitable for such applications. The system combines a 961 pixel imaging array based upon Microwave Kinetic Inductance Detectors (MKIDs) with a readout system capable of reading out all pixels simultaneously with only one readout cable pair and a single cryogenic amplifier. We evaluate, in a representative environment, the system performance in terms of sensitivity, dynamic range, optical efficiency, cosmic ray rejection, pixel-pixel crosstalk and overall yield at at an observation centre frequency of 850 GHz and 20% fractional bandwidth. The overall system has an excellent sensitivity, with an average detector sensitivity NEPdet=3x10^-19 W/rt(Hz) measured using a thermal calibration source. At a loading power per pixel of 50fW we demonstrate white, photon noise limited detector noise down to 300 mHz. The dynamic range would allow the detection of 1 Jy bright sources within the field of view without tuning the readout of the detectors. The expected dead time due to cosmic ray interactions, when operated in an L2 or a similar far-Earth orbit, is found to be <4%. Additionally, the achieved pixel yield is 83% and the crosstalk between the pixels is <-30dB. This demonstrates that MKID technology can provide multiplexing ratios on the order of a 1000 with state-of-the-art single pixel performance, and that the technology is now mature enough to be considered for future space based observatories and experiments.

astro-ph.IM↗

Measurements and analysis of optical crosstalk in a microwave kinetic inductance detector array

The main advantage of Microwave Kinetic Inductance Detector arrays (MKID) is their multiplexing capability, which allows for building cameras with a large number of pixels and good sensitivity, particularly suitable to perform large blank galaxy surveys. However, to have as many pixels as possible it is necessary to arrange detectors close in readout frequency. Consequently KIDs overlap in frequency and are coupled to each other producing crosstalk. Because crosstalk can be only minimised by improving the array design, in this work we aim to correct for this effect a posteriori. We analysed a MKID array consisting of 880 KIDs with readout frequencies at 4-8 GHz. We measured the beam patterns for every detector in the array and described the response of each detector by using a two-dimensional Gaussian fit. Then, we identified detectors affected by crosstalk above -30 dB level from the maximum and removed the signal of the crosstalking detectors. Moreover, we modelled the crosstalk level for each KID as a function of the readout frequency separation starting from the assumption that the transmission of a KID is a Lorenztian function in power. We were able to describe the general crosstalk level of the array and the crosstalk of each KID within 5 dB, so enabling the design of future arrays with the crosstalk as a design criterion. In this work, we demonstrate that it is possible to process MKID images a posteriori to decrease the crosstalk effect, subtracting the response of each coupled KID from the original map.

astro-ph.IM↗

Calibration scheme for large Kinetic Inductance Detector Arrays based on Readout Frequency Response

Microwave kinetic inductance detector (MKID) provides a way to build large ground based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical source power. A signal can be measured in a KID as a change in the phase of the readout signal with respect to the KID resonant circle. Fundamentally, this phase change is due to a shift in the KID resonance frequency, in turn due to a radiation induced change in the quasiparticle number in the superconducting resonator. We show that shift in resonant frequency can be determined from the phase shift by using KID phase versus frequency dependence using a previously measured resonant frequency. Working in this calculated resonant frequency, we gain near linearity and constant calibration to a constant optical signal applied in a wide range of operating points on the resonance and readout powers. This calibration method has three particular advantages: first, it is fast enough to be used to calibrate large arrays, with pixel counts in the thousand of pixels; second, it is based on data that are already necessary to determine KID positions; third, it can be done without applying any optical source in front of the array.

astro-ph.IM↗

The non-equilibrium response of a superconductor to pair-breaking radiation measured over a broad frequency band

We have measured the absorption of terahertz radiation in a BCS superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using a broadband antenna-lens system and a tantalum microwave resonator. From low frequencies, the response of the resonator rises rapidly to a maximum at the gap edge of the superconductor. From there on the response drops to half the maximum response at twice the pair-breaking energy. At higher frequencies, the response rises again due to trapping of pair-breaking phonons in the superconductor. In practice this is the first measurement of the frequency dependence of the quasiparticle creation efficiency due to pair-breaking in a superconductor. The efficiency, calculated from the different non-equilibrium quasiparticle distribution functions at each frequency, is in agreement with the measurements.

cond-mat.supr-con↗

Performance of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors as Direct Detectors for Sub-millimeter Astronomy

In the next decades millimeter and sub-mm astronomy requires large format imaging arrays and broad-band spectrometers to complement the high spatial and spectral resolution of the Atacama Large Millimeter/sub-millimeter Array. The desired sensors for these instruments should have a background limited sensitivity and a high optical efficiency and enable arrays thousands of pixels in size. Hybrid microwave kinetic inductance detectors consisting of NbTiN and Al have shown to satisfy these requirements. We present the second generation hybrid NbTiN-Al MKIDs, which are photon noise limited in both phase and amplitude readout for loading levels $P_{850GHz} \geq 10$ fW. Thanks to the increased responsivity, the photon noise level achieved in phase allows us to simultaneously read out approximately 8000 pixels using state-of-the-art electronics. In addition, the choice of superconducting materials and the use of a Si lens in combination with a planar antenna gives these resonators the flexibility to operate within the frequency range $0.09 < ν< 1.1$ THz. Given these specifications, hybrid NbTiN-Al MKIDs will enable astronomically usable kilopixel arrays for sub-mm imaging and moderate resolution spectroscopy.

astro-ph.IM↗

High optical efficiency and photon noise limited sensitivity of microwave kinetic inductance detectors using phase readout

We demonstrate photon noise limited performance in both phase and amplitude readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN and Al, down to 100 fW of optical power. We simulate the far field beam pattern of the lens-antenna system used to couple radiation into the MKID and derive an aperture efficiency of 75%. This is close to the theoretical maximum of 80% for a single-moded detector. The beam patterns are verified by a detailed analysis of the optical coupling within our measurement setup.

physics.ins-det↗

Design and Testing of Kinetic Inductance Detectors Made of Titanium Nitride

To use highly resistive material for Kinetic Inductance Detectors (KID), new designs have to be done, in part due to the impedance match needed between the KID chip and the whole 50 ohms readout circuit. Chips from two new hybrid designs, with an aluminum throughline coupled to titanium nitride microresonators, have been measured and compared to a TiN only chip. In the hybrid chips, parasitic temperature dependent box resonances are absent. The dark KID properties have been measured in a large set of resonators. A surprisingly long lifetime, up to 5.6 ms is observed in a few KIDs. For the other more reproducible devices, the mean electrical Noise Equivalent Power is 5.4 10-19 W.Hz1/2.

astro-ph.IM↗

On-chip filter bank spectroscopy at 600-700 GHz using NbTiN superconducting resonators

We experimentally demonstrate the principle of an on-chip submillimeter wave filter bank spectrometer, using superconducting microresonators as narrow band-separation filters. The filters are made of NbTiN/SiNx/NbTiN microstrip line resonators, which have a resonance frequency in the range of 614-685 GHz---two orders of magnitude higher in frequency than what is currently studied for use in circuit quantum electrodynamics and photodetectors. The frequency resolution of the filters decreases from 350 to 140 with increasing frequency, most likely limited by dissipation of the resonators.

astro-ph.IM↗

Microwave-induced excess quasiparticles in superconducting resonators measured through correlated conductivity fluctuations

We have measured the number of quasiparticles and their lifetime in aluminium superconducting microwave resonators. The number of excess quasiparticles below 160 mK decreases from 72 to 17 $μ$m$^{-3}$ with a 6 dB decrease of the microwave power. The quasiparticle lifetime increases accordingly from 1.4 to 3.5 ms. These properties of the superconductor were measured through the spectrum of correlated fluctuations in the quasiparticle system and condensate of the superconductor, which show up in the resonator amplitude and phase respectively. Because uncorrelated noise sources vanish, fluctuations in the superconductor can be studied with a sensitivity close to the vacuum noise.

cond-mat.supr-con↗

Photon noise limited radiation detection with lens-antenna coupled Microwave Kinetic Inductance Detectors

Microwave Kinetic Inductance Detectors (MKIDs) have shown great potential for sub-mm instrumentation because of the high scalability of the technology. Here we demonstrate for the first time in the sub-mm band (0.1...2 mm) a photon noise limited performance of a small antenna coupled MKID detector array and we describe the relation between photon noise and MKID intrinsic generation-recombination noise. Additionally we use the observed photon noise to measure the optical efficiency of detectors to be 0.8+-0.2.

astro-ph.IM↗

Integrated Filterbank for DESHIMA: A Submillimeter Imaging Spectrograph Based on Superconducting Resonators

An integrated filterbank (IFB) in combination with microwave kinetic inductance detectors (MKIDs), both based on superconducting resonators, could be used to make broadband submillimeter imaging spectrographs that are compact and flexible. In order to investigate the possibility of adopting an IFB configuration for DESHIMA (Delft SRON High-redshift Mapper), we study the basic properties of a coplanar-waveguide-based IFB using electromagnetic simulation. We show that a coupling efficiency greater than 1/2 can be achieved if transmission losses are negligible. We arrive at a practical design for a 9 pixel x 920 color 3 dimensional imaging device that fits on a 4 inch wafer, which instantaneously covers multiple submillimeter telluric windows with a dispersion of f/df = 1000.

astro-ph.IM↗

Number fluctuations of sparse quasiparticles in a superconductor

We have directly measured quasiparticle number fluctuations in a thin film superconducting Al resonator in thermal equilibrium. The spectrum of these fluctuations provides a measure of both the density and the lifetime of the quasiparticles. We observe that the quasiparticle density decreases exponentially with decreasing temperature, as theoretically predicted, but saturates below 160 mK to 25-55 per cubic micron. We show that this saturation is consistent with the measured saturation in the quasiparticle lifetime, which also explains similar observations in qubit decoherence times.

cond-mat.supr-con↗