SearcharxivSearch

arXiv subjects

S. J. Seltzer

Publications and source records attributed to S. J. Seltzer.

4 recordsLinked to original sources

Investigation of Anti-Relaxation Coatings for Alkali-Metal Vapor Cells Using Surface Science Techniques

Many technologies based on cells containing alkali-metal atomic vapor benefit from the use of anti-relaxation surface coatings in order to preserve atomic spin polarization. In particular, paraffin has been used for this purpose for several decades and has been demonstrated to allow an atom to experience up to 10,000 collisions with the walls of its container without depolarizing, but the details of its operation remain poorly understood. We apply modern surface and bulk techniques to the study of paraffin coatings, in order to characterize the properties that enable the effective preservation of alkali spin polarization. These methods include Fourier transform infrared spectroscopy, differential scanning calorimetry, atomic force microscopy, near-edge X-ray absorption fine structure spectroscopy, and X-ray photoelectron spectroscopy. We also compare the light-induced atomic desorption yields of several different paraffin materials. Experimental results include the determination that crystallinity of the coating material is unnecessary, and the detection of C=C double bonds present within a particular class of effective paraffin coatings. Further study should lead to the development of more robust paraffin anti-relaxation coatings, as well as the design and synthesis of new classes of coating materials.

physics.chem-ph

High-Temperature Alkali Vapor Cells with Anti-Relaxation Surface Coatings

Antirelaxation surface coatings allow long spin relaxation times in alkali-metal cells without buffer gas, enabling faster diffusion of the alkali atoms throughout the cell and giving larger signals due to narrower optical linewidths. Effective coatings were previously unavailable for operation at temperatures above 80 C. We demonstrate that octadecyltrichlorosilane (OTS) can allow potassium or rubidium atoms to experience hundreds of collisions with the cell surface before depolarizing, and that an OTS coating remains effective up to about 170 C for both potassium and rubidium. We consider the experimental concerns of operating without buffer gas and with minimal quenching gas at high vapor density, studying the stricter need for effective quenching of excited atoms and deriving the optical rotation signal shape for atoms with resolved hyperfine structure in the spin-temperature regime. As an example of a high-temperature application of antirelaxation coated alkali vapor cells, we operate a spin-exchange relaxation-free atomic magnetometer with sensitivity of 6 fT/sqrt(Hz) and magnetic linewidth as narrow as 2 Hz.

physics.atom-ph

Detection of NMR signals with a radio-frequency atomic magnetometer

We demonstrate detection of proton NMR signals with a radio frequency atomic magnetometer tuned to the NMR frequency of 62 kHz. High-frequency operation of the atomic magnetometer makes it relatively insensitive to ambient magnetic field noise. We obtain magnetic field sensitivity of 7 fT/Hz$^{1/2}$ using only a thin aluminum shield. We also derive an expression for the fundamental sensitivity limit of a surface inductive pick-up coil as a function of frequency and find that an atomic rf magnetometer is intrinsically more sensitive than a coil of comparable size for frequencies below about 50 MHz.

physics.atom-ph

Synchronous Optical Pumping of Quantum Revival Beats for Atomic Magnetometery

We observe quantum beats with periodic revivals due to non-linear spacing of Zeeman levels in the ground state of potassium atoms and demonstrate their synchronous optical pumping by double modulation of the pumping light at the Larmor frequency and the revival frequency. We show that synchronous pumping increases the degree of spin polarization by a factor of 4. As a practical example, we explore the application of this double-modulation technique to atomic magnetometers operating in the geomagnetic field range and find that it can increase the sensitivity and reduce magnetic field orientation-dependent measurement errors endemic to alkali-metal magnetometers.

physics.atom-ph