Searcharxiv⌕ Search

arXiv subjects

S. Jiménez

Publications and source records attributed to S. Jiménez.

12 recordsLinked to original sources

The Star Formation Factory revisited I. The impact of metallicity on collapsing star-forming clouds

Context. Stellar feedback regulates star formation and shapes the interstellar medium, yet its role during the collapse of molecular clouds remains uncertain over a wide range of initial conditions. Aims. We explore how stellar winds and supernovae influence star formation in collapsing gas clouds that span a broad parameter space in mass, size, and metallicity. Methods. Using a one-dimensional numerical model, we follow the evolution of feedback-driven bubbles produced by embedded clusters, incorporating time-dependent energy and mass injection, self-gravity, integrated cloud collapse, radiative cooling, shell instabilities, and triggered star formation. Our treatment of gas cooling in the hot bubble explicitly accounts for heat transfer across the bubble-shell interface. Results. We find that metallicity acts as a key regulator of feedback, comparable in importance to cloud mass and radius. In low-metallicity clouds, reduced radiative cooling is offset by weaker stellar winds, leading to prolonged star formation and higher efficiencies. Across a substantial portion of parameter space, the expanding shell undergoes a stalling phase that further enhances the star formation efficiency, an outcome that is not observed at higher metallicities. Conclusions. Our results suggest that the diverse properties of star clusters across cosmic time may arise from the metallicity-dependent interplay between stellar feedback and gas cooling.

astro-ph.GA↗

What holes in the gas distribution of nearly face-on galaxies can tell us about the host disk parameters: the case of the NGC 628 South-East superbubble

Here we explore the impact of all major factors, such as the non-homogeneous gas distribution, galactic rotation and gravity, on the observational appearance of superbubbles in nearly face-on spiral galaxies. The results of our 3D numerical simulations are confronted to the observed gas column density distribution in the largest South-East superbubble in the late-type spiral galaxy NGC 628. We make use of the star formation history inside the bubble derived from the resolved stellar population seen in the HST images to obtain its energy and demonstrate that the results of numerical simulations are in good agreement with the observed gas surface density distribution. We also show that the observed gas column density distribution constraints the gaseous disk scale height and the midplane gas density if the energy input rate could be obtained from observations. This implies that observations of large holes in the interstellar gas distribution and their stellar populations have the potential power to solve the midplane gas density - gaseous disk scale-height degeneracy problem in nearly face-on galaxies. The possible role of superbubbles in driving the secondary star formation in galaxies is also briefly discussed.

astro-ph.GA↗

Neutrino Physics with an Opaque Detector

In 1956 Reines & Cowan discovered the neutrino using a liquid scintillator detector. The neutrinos interacted with the scintillator, producing light that propagated across transparent volumes to surrounding photo-sensors. This approach has remained one of the most widespread and successful neutrino detection technologies used since. This article introduces a concept that breaks with the conventional paradigm of transparency by confining and collecting light near its creation point with an opaque scintillator and a dense array of optical fibres. This technique, called LiquidO, can provide high-resolution imaging to enable efficient identification of individual particles event-by-event. A natural affinity for adding dopants at high concentrations is provided by the use of an opaque medium. With these and other capabilities, the potential of our detector concept to unlock opportunities in neutrino physics is presented here, alongside the results of the first experimental validation.

physics.ins-det↗

ProtoDUNE-DP Light Acquisition and Calibration Software

ProtoDUNE-DP is a 6x6x6 m3 liquid argon time-projection-chamber operated at the CERN Neutrino Platform in 2019-2020 as a prototype of the Dual Phase concept for the DUNE Far Detector. The Photon Detection System (PDS) is based on 36 8-inch photo-multiplier tubes (PMTs) and allows triggering on the scintillation light signals produced by cosmic rays and other charged particles traversing the detector. The acquisition and calibration software specifically developed for the ProtoDUNE-DP PDS is described in this paper. This software controls the high-voltage power supplies, the calibration system, and the PDS DAQ. It has been developed with Qt Creator, and features different operation modes, and a graphical user interface. This software has already been validated and used during the ProtoDUNE-DP operation.

physics.ins-det↗

Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC

The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performances of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.

physics.ins-det↗

First testing of the Hamamatsu R5912-02Mod photomultiplier tube at 4-bar pressure and cryogenic temperature

The Hamamatsu R5912-02Mod photomultiplier tube (PMT) will be used in the DUNE dual-phase module, a 10-kton fiducial volume liquid-argon time-projection chamber, which is one of the four projected far-detector modules of the DUNE long-baseline neutrino experiment. In the DUNE dual-phase module, the liquid argon places high pressure on the photo-detectors located at the bottom of the 14-m cryostat. Four Hamamatsu R5912-02Mod PMTs were tested at 4-bar absolute pressure and cryogenic temperature (in liquid nitrogen) for the first time. No mechanical or electrical damage is reported, validating the use of this PMT model in the DUNE dual-phase module and in other large scale cryogenic liquid detectors. The differences observed in their behavior are expected for the change in the PMT operating temperature.

physics.ins-det↗

A Light Calibration System for the ProtoDUNE-DP Detector

A LED-based fiber calibration system for the ProtoDUNE-Dual Phase (DP) photon detection system (PDS) has been designed and validated. ProtoDUNE-DP is a 6x6x6 m3 liquid argon time-projection-chamber currently being installed at the Neutrino Platform at CERN. The PDS is based on 36 8-inch photomultiplier tubes (PMTs) and will allow triggering on cosmic rays. The system serves as prototype for the PDS of the final DUNE DP far detector in which the PDS also has the function to allow the 3D event reconstruction on non-beam physics. For this purpose an equalized PMT response is desirable to allow using the same threshold definition for all PMT groups, simplifying the determination of the trigger efficiency. The light calibration system described in this paper is developed to provide this and to monitor the PMT performance in-situ.

physics.ins-det↗

New combinational therapies for cancer using modern statistical mechanics

We investigate a new dynamical system that describes tumor-host interaction. The equation that describes the untreated tumor growth is based on non-extensive statistical mechanics. Recently, this model has been shown to fit successfully exponential, Gompertz, logistic, and power-law tumor growths. We have been able to include as many hallmarks of cancer as possible. We study also the dynamic response of cancer under therapy. Using our model, we can make predictions about the different outcomes when we change the parameters, and/or the initial conditions. We can determine the importance of different factors to influence tumor growth. We discover synergistic therapeutic effects of different treatments and drugs. Cancer is generally untreatable using conventional monotherapy. We consider conventional therapies, oncogene-targeted therapies, tumor-suppressors gene-targeted therapies, immunotherapies, anti-angiogenesis therapies, virotherapy, among others. We need therapies with the potential to target both tumor cells and the tumors' microenvironment. Drugs that target oncogenes and tumor-suppressor genes can be effective in the treatment of some cancers. However, most tumors do reoccur. We have found that the success of the new therapeutic agents can be seen when used in combination with other cancer-cell-killing therapies. Our results have allowed us to design a combinational therapy that can lead to the complete eradication of cancer.

physics.bio-ph↗

Cryogenic R5912-20Mod Photomultiplier Tube Characterization for the ProtoDUNE Dual Phase Detector

The Deep Underground Neutrino Experiment (DUNE) is a dual-site experiment for long baseline neutrino oscillation studies, and for neutrino astrophysics and nucleon decay searches. The far detector is a 40-kton underground liquid argon time-projection-chamber (LAr TPC), in which the photon detector system adds precise timing capabilities. The ProtoDUNE dual phase detector will consist of a 6x6x6 m^3 LAr TPC to be operated at the CERN Neutrino Platform and the photon detection system will be formed by 8-inch cryogenic photomultipliers from Hamamatsu. The PMT model (R5912-20Mod) performance at cryogenic temperature is studied including dark current, gain, and linearity with the light intensity and pulse rate. In addition, the PMT base design is validated. At cold, a decrease of the PMT amplification, or fatigue effect, is measured as the PMT output current increases, either, due to high gain, light intensity or rate. Also, the characterisation results of the 40 photomultipliers to be used in ProtoDUNE dual phase are presented.

physics.ins-det↗

Fate of the true-vacuum bubbles

We investigate the bounce solutions in vacuum decay problems. We show that it is possible to have a stable false vacuum in a potential that is unbounded from below.

hep-th↗

Characterization of the Spontaneous Light Emission of the PMTs used in the Double Chooz Experiment

During the commissioning of the first of the two detectors of the Double Chooz experiment, an unexpected and dominant background caused by the emission of light inside the optical volume has been observed. A specific study of the ensemble of phenomena called "Light Noise" has been carried out in-situ, and in an external laboratory, in order to characterize the signals and to identify the possible processes underlying the effect. Some mechanisms of instrumental noise originating from the PMTs were identified and it has been found that the leading one arises from the light emission localized on the photomultiplier base and produced by the combined effect of heat and high voltage across the transparent epoxy resin covering the electric components. The correlation of the rate and the amplitude of the signal with the temperature has been observed. For the first detector in operation the induced background has been mitigated using online and offline analysis selections based on timing and light pattern of the signals, while a modification of the photomultiplier assembly has been implemented for the second detector in order to blacken the PMT bases.

physics.ins-det↗