SearcharxivSearch

arXiv subjects

S. Kado

Publications and source records attributed to S. Kado.

2 recordsLinked to original sources

Sensitivity of a low-shear heliotron configuration to localised ferrite perturbations

The influence of ferritic steel on low-shear stellarator/heliotron magnetic configurations is investigated for the Heliotron J device using a point dipole magnetisation model. By numerically evaluating ferritic steel plates assumed at several locations inside the Heliotron J vacuum vessel, the changes in the rotational transform and magnetic island width are shown to be sensitive to the installation location. This sensitivity arises from the coupling between the background nonaxisymmetric field and ferrite perturbation, rather than being determined solely by the perturbation amplitude. Ferritic steel plates placed on the outer side of a straight section produce the most significant changes in the magnetic topology and exhibit the highest sensitivity to violations of the $M = 4$ toroidal periodicity. Additionally, we show that appropriate arrangements of passive magnetic dipoles can reduce the effective helical ripple while preserving the vacuum magnetic well depth in Heliotron J, and can induce stellaratorasymmetric boundary perturbation in low-field experiments near the ferrite saturation threshold.

physics.plasm-ph

Development of the poloidal Charge eXchange Recombination Spectroscopy system in Heliotron J

A Charge eXchange Recombination Spectroscopy (CXRS) system designed to measure the poloidal rotation velocity is developed in Heliotron J. The poloidal CXRS system measures the carbon emission line (C VI, n=8-7, 529.05nm) and the Doppler shift of the emission line provides the information of plasma rotation velocity. A high throughput photographic-lens monochromator (F/2.8) with 0.73nm/mm dispersion is adopted to achieve high rotation velocity and temporal resolution. Since two heating neutral beams from two tangential injectors (NBI) are used as the diagnostic beams, a wide observation range (0.26 < 0.06) at peripheral region (r/a>0.6). The system design and the calibration method are presented. The initial results of poloidal rotation measurement show an electron diamagnetic rotation in an NBI heated plasma, while an ion diamagnetic rotation is observed when ECH is additionally applied. The evaluated radial electric field profile shows a positive Er at plasma core region in the ECH+NBI plasma, and a negative Er in the NBI heated plasma.

physics.plasm-ph