Searcharxiv⌕ Search

arXiv subjects

S. Kananov

Publications and source records attributed to S. Kananov.

22 records · Page 2Linked to original sources

Measurement of neutral current e+/-p cross sections at high Bjorken x with the ZEUS detector

The neutral current e+/-p cross section has been measured up to values of Bjorken x of approximately 1 with the ZEUS detector at HERA using an integrated luminosity of 187 inv. pb of e-p and 142 inv. pb of e+p collisions at sqrt(s) = 318GeV. Differential cross sections in x and Q2, the exchanged boson virtuality, are presented for Q2 geq 725GeV2. An improved reconstruction method and greatly increased amount of data allows a finer binning in the high-x region of the neutral current cross section and leads to a measurement with much improved precision compared to a similar earlier analysis. The measurements are compared to Standard Model expectations based on a variety of recent parton distribution functions.

hep-ex↗

Radiative Corrections for Pion Polarizability Experiments

We use the semi-analytical program RCFORGV to evaluate radiative corrections to one-photon radiative emission in the high-energy scattering of pions in the Coulomb field of a nucleus with atomic number Z. It is shown that radiative corrections can simulate a pion polarizability effect. The average effect was estimated for pion energies 40-600 GeV. We also study the range of applicability of the equivalent photon approximation in describing one-photon radiative emission.

hep-ph↗

Monte Carlo study of a luminosity detector for the International Linear Collider

This paper presents the status of Monte Carlo simulation of one of the luminosity detectors considered for the future e+e- International Linear Collider (ILC). The detector consists of a tungsten/silicon sandwich calorimeter with pad readout. The study was performed for Bhabha scattering events assuming a zero crossing angle for the beams.

physics.ins-det↗

Separation of γ/π^0 showers at high energies

We have designed and carried out simulation studies of a two layer Shower Maximum Detector diagonally off-set (SMD-dos) optimized for the separation of π^0 showers from γshowers in the 30 to 150 GeV energy range. For 90% γacceptance the SMD-dos yields π^0 rejection efficiency of 92+-4%, 87+-4% and 32+-2%, respectively, for 30, 50 and 150 GeV incident energies. We find that the SMD-dos is superior to a conventional geometry single-layer or mutiple-layer shower maximum detector (SMD), of equal granularity, by an average factor of ~1.5 over the 50 to 150 GeV energy range. We also find that the SMD-dos gives better π^0 rejection, for the same number of channels, than a SMD. At hadron - hadron colliders the signature of choice for the detection of the Higgs particle, in the mass range of 120 to 160 GeV, is via the decay H-->γγ. The addition of a SMD-dos to the planned detectors at the LHC would significantly reduce the background to the γ-signal coming from prolific π^0 production.

hep-ex↗