SearcharxivSearch

arXiv subjects

S. Kanda

Publications and source records attributed to S. Kanda.

10 recordsLinked to original sources

Few-electron highly charged muonic Ar atoms verified by electronic $K$ x rays

Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms were identified from electronic $K$ x rays and hyper-satellite $K$ x rays. These $K$ x rays are emitted after the charge transfer process by the collisions with surrounding Ar atoms. With the aid of theoretical calculations, we confirmed that the peak positions are consistent with the x-ray energies from highly charged Cl ions, and the intensities reflecting deexcitation dynamics were successfully understood by taking into account the interaction between the muon and bound electrons.

physics.atom-ph

Improved Measurements of Muonic Helium Ground-State Hyperfine Structure at a Near-Zero Magnetic Field

Muonic helium atom hyperfine structure (HFS) measurements are a sensitive tool to test the three-body atomic system and bound-state quantum electrodynamics theory, and determine fundamental constants of the negative muon magnetic moment and mass. The world's most intense pulsed negative muon beam at the Muon Science Facility of the Japan Proton Accelerator Research Complex allows improvement of previous measurements and testing further $CPT$ invariance by comparing the magnetic moments and masses of positive and negative muons (second-generation leptons). We report new ground-state HFS measurements of muonic helium-4 atoms at a near-zero magnetic field, performed for the first time using a small admixture of CH$_{4}$ as an electron donor to form neutral muonic helium atoms efficiently. Our analysis gives $\Delta\nu$ = 4464.980(20) MHz (4.5 ppm), which is more precise than both previous measurements at weak and high fields. The muonium ground-state HFS was also measured under the same conditions to investigate the isotopic effect on the frequency shift due to the gas density dependence in He with CH$_{4}$ admixture and compared with previous studies. Muonium and muonic helium can be regarded as light and heavy hydrogen isotopes with an isotopic mass ratio of 36. No isotopic effect was observed within the current experimental precision.

physics.atom-ph

Development of microwave cavities for measurement of muonium hyperfine structure at J-PARC

The MuSEUM collaboration is planning measurements of the ground-state hyperfine structure (HFS) of muonium at the Japan Proton Accelerator Research Complex (J-PARC), Materials and Life Science Experimental Facility. The high-intensity beam that will soon be available at H-line allows for more precise measurements by one order of magnitude. We plan to conduct two staged measurements. First, we will measure the Mu-HFS in a near-zero magnetic field, and thereafter we will measure it in a strong magnetic field. We have developed two microwave cavities for this purpose. Furthermore, we evaluated systematic uncertainties from such a fluctuation of microwave fields and confirm the requirement of the microwave system, we use a microwave field distribution calculated from the finite element method.

physics.ins-det

Rabi-Oscillation Spectroscopy of the Hyperfine Structure of Muonium Atoms

As a new method to determine the resonance frequency, Rabi-oscillation spectroscopy has been developed. In contrast to the conventional spectroscopy which draws the resonance curve, Rabi-oscillation spectroscopy fits the time evolution of the Rabi oscillation. By selecting the optimized frequency, it is shown that the precision is twice as good as the conventional spectroscopy with a frequency sweep. Furthermore, the data under different conditions can be treated in a unified manner, allowing more efficient measurements for systems consisting of a limited number of short-lived particles produced by accelerators such as muons. We have developed a fitting function that takes into account the spatial distribution of muonium and the spatial distribution of the microwave intensity to apply the new method to ground-state muonium hyperfine structure measurements at zero field. This was applied to the actual measurement data and the resonance frequencies were determined under various conditions. The result of our analysis gives $\nu_{\rm HFS}=4\ 463\ 301.61 \pm 0.71\ {\rm kHz}$, which is the world's highest precision under zero field conditions.

hep-ex

New precise spectroscopy of the hyperfine structure in muonium with a high-intensity pulsed muon beam

A hydrogen-like atom consisting of a positive muon and an electron is known as muonium. It is a near-ideal two-body system for a precision test of bound-state theory and fundamental symmetries. The MuSEUM collaboration performed a new precision measurement of the muonium ground-state hyperfine structure at J-PARC using a high-intensity pulsed muon beam and a high-rate capable positron counter. The resonance of hyperfine transition was successfully observed at a near-zero magnetic field, and the muonium hyperfine structure interval of ${\nu}_{\text{HFS}}$ = 4.463302(4) GHz was obtained with a relative precision of 0.9 ppm. The result was consistent with the previous ones obtained at Los Alamos National Laboratory and the current theoretical calculation. We present a demonstration of the microwave spectroscopy of muonium for future experiments to achieve the highest precision.

hep-ex

A New Approach for Measuring the Muon Anomalous Magnetic Moment and Electric Dipole Moment

This paper introduces a new approach to measure the muon magnetic moment anomaly $a_{\mu} = (g-2)/2$, and the muon electric dipole moment (EDM) $d_{\mu}$ at the J-PARC muon facility. The goal of our experiment is to measure $a_{\mu}$ and $d_{\mu}$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon $g-2$ experiments with unprecedented quality of the storage magnetic field. Additional significant differences from the present experimental method include a factor of 1,000 smaller transverse emittance of the muon beam (reaccelerated thermal muon beam), its efficient vertical injection into the solenoid, and tracking each decay positron from muon decay to obtain its momentum vector. The precision goal for $a_{\mu}$ is statistical uncertainty of 450 part per billion (ppb), similar to the present experimental uncertainty, and a systematic uncertainty less than 70 ppb. The goal for EDM is a sensitivity of $1.5\times 10^{-21}~e\cdot\mbox{cm}$.

physics.ins-det

Enhancement of muonium emission rate from silica aerogel with a laser ablated surface

Emission of muonium ($μ^+e^-$) atoms from a laser-processed aerogel surface into vacuum was studied for the first time. Laser ablation was used to create hole-like regions with diameter of about 270$~μ$m in a triangular pattern with hole separation in the range of 300--500$~μ$m. The emission probability for the laser-processed aerogel sample is at least eight times higher than for a uniform one.

physics.ins-det

Measurement of muonium emission from silica aerogel

Emission of muonium ($μ^{+}e^{-}$) atoms from silica aerogel into vacuum was observed. Characteristics of muonium emission were established from silica aerogel samples with densities in the range from 29 mg cm$^{-3}$ to 178 mg cm$^{-3}$. Spectra of muonium decay times correlated with distances from the aerogel surfaces, which are sensitive to the speed distributions, follow general features expected from a diffusion process, while small deviations from a simple room-temperature thermal diffusion model are identified. The parameters of the diffusion process are deduced from the observed yields.

physics.atom-ph

The Cherenkov Correlated Timing Detector: Beam Test Results from Quartz and Acrylic Bars

Several prototypes of a Cherenkov Correlated Timing (CCT) Detector have been tested at the KEK-PS test beam line. We describe the results for Cherenkov light yields and timing characteristics from quartz and acrylic bar prototypes. A Cherenkov angle resolution is found to be 15 mrad at a propagation distance of 100 cm with a 2 cm thick quartz bar prototype.

hep-ex