SearcharxivSearch

arXiv subjects

S. Karpuk

Publications and source records attributed to S. Karpuk.

12 recordsLinked to original sources

Polarization-Dependent Disappearance of a Resonance Signal -- Indication for Optical Pumping in a Storage Ring?

We report on laser spectroscopic measurements on Li$^+$ ions in the experimental storage ring ESR at the GSI Helmholtz Centre for Heavy Ion Research. Driving the $2s\,^3\!{S}_1\;(F=\frac{3}{2}) \,\leftrightarrow\,2p\,^3\!P_2\;(F=\frac{5}{2}) \leftrightarrow 2s\,^3\!{S}_1\;(F=\frac{5}{2})$ $Λ$-transition in $^7$Li$^+$ with two superimposed laser beams it was found that the use of circularly polarized light leads to a disappearance of the resonance structure in the fluorescence signal. This can be explained by optical pumping into a dark state of polarized ions. We present a detailed theoretical analysis of this process that supports the interpretation of optical pumping and demonstrates that the polarization induced by the laser light must then be at least partially maintained during the round trip of the ions in the storage ring. Such polarized ion beams in storage rings will provide opportunities for new experiments, especially on parity violation.

physics.atom-ph

Measurement of the Permanent Electric Dipole Moment of the $^{129}$Xe Atom

We report on a new measurement of the CP-violating permanent Electric Dipole Moment (EDM) of the neutral $^{129}$Xe atom. Our experimental approach is based on the detection of the free precession of co-located nuclear spin-polarized $^3$He and $^{129}$Xe samples. The EDM measurement sensitivity benefits strongly from long spin coherence times of several hours achieved in diluted gases and homogeneous weak magnetic fields of about 400~nT. A finite EDM is indicated by a change in the precession frequency, as an electric field is periodically reversed with respect to the magnetic guiding field. Our result, $\left(-4.7\pm6.4\right)\cdot 10^{-28}$ ecm, is consistent with zero and is used to place a new upper limit on the $^{129}$Xe EDM: $|d_\text{Xe}|<1.5 \cdot 10^{-27}$ ecm (95% C.L.). We also discuss the implications of this result for various CP-violating observables as they relate to theories of physics beyond the standard model.

physics.atom-ph

Comparison of ultracold neutron sources for fundamental physics measurements

Ultracold neutrons (UCNs) are key for precision studies of fundamental parameters of the neutron and in searches for new CP violating processes or exotic interactions beyond the Standard Model of particle physics. The most prominent example is the search for a permanent electric dipole moment of the neutron (nEDM). We have performed an experimental comparison of the leading UCN sources currently operating. We have used a 'standard' UCN storage bottle with a volume of 32 liters, comparable in size to nEDM experiments, which allows us to compare the UCN density available at a given beam port.

physics.ins-det

Precise Measurement of Magnetic Field Gradients from Free Spin Precession Signals of $^{3}$He and $^{129}$Xe Magnetometers

We report on precise measurements of magnetic field gradients extracted from transverse relaxation rates of precessing spin samples. The experimental approach is based on the free precession of gaseous, nuclear spin polarized $^3$He and $^{129}$Xe atoms in a spherical cell inside a magnetic guiding field of about 400 nT using LT$_C$ SQUIDs as low-noise magnetic flux detectors. The transverse relaxation rates of both spin species are simultaneously monitored as magnetic field gradients are varied. For transverse relaxation times reaching 100 h, the residual longitudinal field gradient across the spin sample could be deduced to be$|\vec{\nabla}B_z|=(5.6 \pm 0.4)$ pT/cm. The method takes advantage of the high signal-to-noise ratio with which the decaying spin precession signal can be monitored that finally leads to the exceptional accuracy to determine magnetic field gradients at the sub pT/cm scale.

physics.atom-ph

Ultrasensitive 3He magnetometer for measurements of high magnetic fields

We describe a 3He magnetometer capable to measure high magnetic fields (B > 0.1 Tesla) with a relative accuracy of better than 10^-12. Our approach is based on the measurement of the free induction decay of gaseous, nuclear spin polarized 3He following a resonant radio frequency pulse excitation. The measurement sensitivity can be attributed to the long coherent spin precession time T2* being of order minutes which is achieved for spherical sample cells in the regime of motional narrowing where the disturbing influence of field inhomogeneities is strongly suppressed. The 3He gas is spin polarized in-situ using a new, non-standard variant of the metastability exchange optical pumping. We show that miniaturization helps to increase T2* further and that the measurement sensitivity is not significantly affected by temporal field fluctuations of order 10^-4.

physics.ins-det

New limit on Lorentz and CPT violating neutron spin interactions using a free precession 3He-129Xe co-magnetometer

We report on the search for a CPT and Lorentz invariance violating coupling of the 3He and 129Xe nuclear spins (each largely determined by a valence neutron) to background tensor fields which permeate the universe. Our experimental approach is to measure the free precession of nuclear spin polarized 3He and 129Xe atoms in a homogeneous magnetic guiding field of about 400 nT using LTC SQUIDs as low-noise magnetic flux detectors. As the laboratory reference frame rotates with respect to distant stars, we look for a sidereal modulation of the Larmor frequencies of the co-located spin samples. As a result we obtain an upper limit on the equatorial component of the background field interacting with the spin of the bound neutron bn< 6.7*10^-34 GeV (68% C.L.). Our result improves our previous limit (data measured in 2009) by a factor of 30 and the world's best limit by a factor of 5.

gr-qc

Modern Ives-Stilwell Experiments At Storage Rings: Large Boosts Meet High Precision

We give a brief overview of time dilation tests using high-resolution laser spectroscopy at heavy-ion storage rings. We reflect on the various methods used to eliminate the first-order Doppler effect and on the pitfalls encountered, and comment on possible extensions at future facilities providing relativistic heavy ion beams at $γ\gg 1$.

physics.atom-ph

Probing Physics beyond the Standard Model with He/Xe clock comparison experiments

The comparison of the free precession of co-located 3He-129Xe spins (clock comparison) enables us to search for very tiny nonmagnetic spin interactions. With our setup we could establish new limits for Lorentz invariance violating interactions of spins with a relic background field which permeates the Universe and points in a preferred direction in space.

hep-ph

Using a rotating magnetic guiding field for the 3He-129Xe-Comagnetometer

Our search for non-magnetic spin-dependent interactions is based on the measurement of free precession of nuclear spin polarized 3He and 129Xe atoms in a homogeneous magnetic guiding field of about 400 nT. We report on our approach to perform an adiabatic rotation of the guiding field that allows us to modulate possible non-magnetic spin-dependent interactions and to find an optimization procedure for long transverse relaxation times T2* both for Helium and Xenon.

hep-ph

Comment on "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions"

In an article "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions" by S. Devasia [arXiv:1003.2970v1], our recent Doppler shift experiments on fast ion beams are reanalyzed. Contrary to our analysis, Devasia concludes that our results provide an "indication of Lorentz violation". We argue that this conclusion is based on a fundamental misunderstanding of our experimental scheme and reiterate that our results are in excellent agreement with Special Relativity.

physics.atom-ph

Limit on Lorentz and CPT violation of the bound Neutron Using a Free Precession 3He/129Xe co-magnetometer

We report on the search for Lorentz violating sidereal variations of the frequency difference of co-located spin-species while the Earth and hence the laboratory reference frame rotates with respect to a relic background field. The co-magnetometer used is based on the detection of freely precessing nuclear spins from polarized 3He and 129Xe gas samples using SQUIDs as low-noise magnetic flux detectors. As result we can determine the limit for the equatorial component of the background field interacting with the spin of the bound neutron to be bn < 3.7 x 10^{-32} GeV (95 C.L.).

gr-qc

Test of Lorentz Symmetry by using a 3He/129Xe Co-Magnetometer

To test Lorentz symmetry we used a 3He/129Xe co-magnetometer. We will give a short summary of our experimental setup and the results of our latest measurements. We obtained preliminary results for the equatorial component of the background field interacting with the spin of the bound neutron: b_n < 3.72 x 10^(-32) GeV (95 C.L.).

hep-ph