SearcharxivSearch

arXiv subjects

S. Kempf

Publications and source records attributed to S. Kempf.

At least 19 recordsLinked to original sources

A study of neutrinoless double electron capture in $^{40}$Ca from the AMoRE experiment

The search for neutrinoless double electron capture ($0\nu\mathrm{2EC}$) provides a sensitive probe of lepton-number violation and the Majorana nature of neutrinos. We investigate the $0\nu\mathrm{2EC}$ decay of $^{40}$Ca using cryogenic detectors equipped with metallic magnetic calorimeters in the AMoRE-I experiment. The analysis is based on a physics dataset corresponding to a total exposure of 7.32 kg$\cdot$yr from thirteen $^{40}$Ca$^{100}$MoO$_4$ crystals. No significant excess is observed, and a lower limit on the half-life is obtained as $T^{0\nu}_{1/2} > 1.7 \times 10^{22}$ yr at 90$\%$ confidence level. An improved sensitivity is expected for the upcoming AMoRE-II experiment. These results demonstrate the potential of CaMoO$_4$ detectors to explore rare decay processes beyond the primary $^{100}$Mo $0\nu\beta\beta$ search program.

nucl-ex

Microwave SQUID Multiplexer Readout Performance Using a Direct-RF RFSoC-Based Software-Defined Radio

In this work, we report the experimental readout results of a {\mu}MUX device using a Direct-RF SDR prototype based on the ZCU216 Radio-Frequency System-on-Chip (RFSoC) evaluation board. First, the analog performance of the SDR system was evaluated both in loopback and coupled to the cryogenic multiplexing system. Then, the SDR system performance was optimized for {\mu}MUX readout, focusing on bolometric applications. Finally, the minimum demodulated flux noise was obtained through the optimally conditioned readout of a {\mu}MUX channel. The results presented are comparable to those obtained with traditional SDR architectures and demonstrate that the Direct-RF SDR prototype is suitable for the readout of {\mu}MUX devices. We anticipate that Direct-RF SDR technology will play a key role in enabling the next generation of SDR readout systems for frequency-multiplexed low-temperature detector arrays.

physics.ins-det

Development of a microwave SQUID multiplexer for magnetic microbolometers

The search for primordial B-modes in the cosmic microwave background (CMB) requires highly sensitive and scalable detector systems. The magnetic microbolometer (MMB) is an emerging detector concept that exploits the magnetic properties of paramagnetic materials at sub-kelvin temperatures, offering bolometers with a high dynamic range and low intrinsic noise. In recent years, the microwave SQUID multiplexer ($\mu$MUX) has become a key technology to efficiently read large low temperature detector arrays, enabling the readout of hundreds to thousands of detectors over a single transmission line with low noise and minimal power dissipation while reducing the cryogenic setup complexity. In this work, we report the design, fabrication and characterization of a $\mu$MUX optimized for MMB detectors and share our latest experimental results from a bolometer prototype. These findings provide valuable insight of the $\mu$MUX in advancing next-generation CMB instrumentation and also demonstrate its suitability for novel detector technologies such as the MMB.

physics.ins-det

Full-scale Microwave SQUID Multiplexer Readout System for Magnetic Microcalorimeters

The deployment of large cryogenic detector arrays, comprising hundreds to thousands of individual detectors, is highly beneficial for various cutting-edge applications, requiring large statistics, angular resolution or imaging capabilities. The readout of such arrays, however, presents a major challenge in terms of system complexity, parasitic heat load, and cost, which can be overcome only through multiplexing. Among the various multiplexing approaches, microwave SQUID multiplexing currently represents the state of the art, in particular for magnetic microcalorimeter (MMC) readout. In this work, we demonstrate the successful operation of the latest generation of our microwave SQUID multiplexer-based readout system, based on a SQUID multiplexer tailored for MMC readout and a custom full-scale software-defined radio (SDR) electronics, capable of handling up to 400 channels. The system operates reliably across the entire 4-8 GHz frequency band and achieves sufficiently low flux noise levels in flux-ramp-demodulated readout. Our results confirm that our system is fully functional and provides a scalable path towards future large-scale, high-resolution MMC experiments.

physics.ins-det

Development of MMC-based lithium molybdate cryogenic calorimeters for AMoRE-II

The AMoRE collaboration searches for neutrinoless double beta decay of $^{100}$Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have demonstrated competitive discovery potential. Presently, the AMoRE-II experiment, featuring a large detector array with about 90 kg of $^{100}$Mo isotope, is under construction. This paper discusses the baseline design and characterization of the lithium molybdate cryogenic calorimeters to be used in the AMoRE-II detector modules. The results from prototype setups that incorporate new housing structures and two different crystal masses (316 g and 517 - 521 g), operated at 10 mK temperature, show energy resolutions (FWHM) of 7.55 - 8.82 keV at the 2.615 MeV $^{208}$Tl $\gamma$ line, and effective light detection of 0.79 - 0.96 keV/MeV. The simultaneous heat and light detection enables clear separation of alpha particles with a discrimination power of 12.37 - 19.50 at the energy region around $^6$Li(n, $\alpha$)$^3$H with Q-value = 4.785 MeV. Promising detector performances were demonstrated at temperatures as high as 30 mK, which relaxes the temperature constraints for operating the large AMoRE-II array.

physics.ins-det

Improved limit on neutrinoless double beta decay of $^{100}$Mo from AMoRE-I

AMoRE searches for the signature of neutrinoless double beta decay of $^{100}$Mo with a 100 kg sample of enriched $^{100}$Mo. Scintillating molybdate crystals coupled with a metallic magnetic calorimeter operate at milli-Kelvin temperatures to measure the energy of electrons emitted in the decay. As a demonstration of the full-scale AMoRE, we conducted AMoRE-I, a pre-experiment with 18 molybdate crystals, at the Yangyang Underground Laboratory for over two years. The exposure was 8.02 kg$\cdot$year (or 3.89 kg$_{\mathrm{^{100}Mo}}\cdot$year) and the total background rate near the Q-value was 0.025 $\pm$ 0.002 counts/keV/kg/year. We observed no indication of $0\nu\beta\beta$ decay and report a new lower limit of the half-life of $^{100}$Mo $0\nu\beta\beta$ decay as $ T^{0\nu}_{1/2}>2.9\times10^{24}~\mathrm{yr}$ at 90\% confidence level. The effective Majorana mass limit range is $m_{\beta\beta}<$(210--610) meV using nuclear matrix elements estimated in the framework of different models, including the recent shell model calculations.

nucl-ex

Projected background and sensitivity of AMoRE-II

AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located approximately 1000 meters deep in Jeongseon, Korea. The goal of AMoRE-II is to reach up to $T^{0\nu\beta\beta}_{1/2}$ $\sim$ 6 $\times$ 10$^{26}$ years, corresponding to an effective Majorana mass of 15 - 29 meV, covering all the inverted mass hierarchy regions. To achieve this, the background level of the experimental configurations and possible background sources of gamma and beta events should be well understood. We have intensively performed Monte Carlo simulations using the GEANT4 toolkit in all the experimental configurations with potential sources. We report the estimated background level that meets the 10$^{-4}$counts/(keV$\cdot$kg$\cdot$yr) requirement for AMoRE-II in the region of interest (ROI) and show the projected half-life sensitivity based on the simulation study.

physics.ins-det

Optimal Demodulation Domain for Microwave SQUID Multiplexers in Presence of Readout System Noise

The Microwave SQUID Multiplexer ({\mu}MUX) is the device of choice for the readout of a large number of Low-Temperature Detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold and warm-readout electronic systems used to read it out, as well as the demodulation domain and parameters chosen. In order to understand the impact of the readout systems in the overall detection system noise performance, first we extended the available {\mu}MUX simulation frameworks including additive and multiplicative noise sources in the probing tones (i.e. phase and amplitude noise), along with the capability of demodulating the scientific data, either in resonator's phase or scattering amplitude. Then, considering the additive noise as a dominant noise source, the optimum readout parameters to achieve minimum system noise were found for both open-loop and flux-ramp demodulation schemes in the aforementioned domains. Later, we evaluated the system noise sensitivity to multiplicative noise sources under the optimum readout parameters. Finally, as a case study, we evaluated the optimal demodulation domain and expected system noise level for a typical Software-Defined Radio (SDR) readout system. This work leads to an improved system performance prediction and noise engineering based on the available readout electronics and selected demodulation domain.

physics.ins-det

Full-Scale Readout Electronics for the ECHo-100k Experiment

Recent advances in the development of cryogenic particle detectors such as magnetic microcalorimeters (MMCs) allow the fabrication of sensor arrays with an increasing number of pixels. Since these detectors must be operated at the lowest temperatures, the readout of large detector arrays is still quite challenging. This is especially true for the ECHo experiment, which presently aims to simultaneously run 6,000 two-pixel detectors to investigate the electron neutrino mass. For this reason, we developed a readout system based on a microwave SQUID multiplexer ($\mu$MUX) that is operated by a custom software-defined radio (SDR) at room-temperature. The SDR readout electronics consist of three distinct hardware units: a data processing board with a Xilinx ZynqUS+ MPSoC; a converter board that features DACs, ADCs, and a coherent clock distribution network; and a radio frequency front-end board to translate the signals between the baseband and the microwave domains. Here, we describe the characteristics of the full-scale SDR system. First, the generated frequency comb for driving the $\mu$MUX was evaluated. Subsequently, by operating the SDR in direct loopback, the crosstalk of the individual channels after frequency demultiplexing was investigated. Finally, the system was used with a 16-channel $\mu$MUX to evaluate the linearity of the SDR, and the noise contributed to the overall readout setup.

physics.ins-det

Background study of the AMoRE-pilot experiment

We report a study on the background of the Advanced Molybdenum-Based Rare process Experiment (AMoRE), a search for neutrinoless double beta decay (\znbb) of $^{100}$Mo. The pilot stage of the experiment was conducted using $\sim$1.9 kg of \CAMOO~ crystals at the Yangyang Underground Laboratory, South Korea, from 2015 to 2018. We compared the measured $\beta/\gamma$ energy spectra in three experimental configurations with the results of Monte Carlo simulations and identified the background sources in each configuration. We replaced several detector components and enhanced the neutron shielding to lower the background level between configurations. A limit on the half-life of $0\nu\beta\beta$ decay of $^{100}$Mo was found at $T_{1/2}^{0\nu} \ge 3.0\times 10^{23}$ years at 90\% confidence level, based on the measured background and its modeling. Further reduction of the background rate in the AMoRE-I and AMoRE-II are discussed.

nucl-ex

Moonraker -- Enceladus Multiple Flyby Mission

Enceladus, an icy moon of Saturn, possesses an internal water ocean and jets expelling ocean material into space. Cassini investigations indicated that the subsurface ocean could be a habitable environment having a complex interaction with the rocky core. Further investigation of the composition of the plume formed by the jets is necessary to fully understand the ocean, its potential habitability, and what it tells us about Enceladus' origin. Moonraker has been proposed as an ESA M-class mission designed to orbit Saturn and perform multiple flybys of Enceladus, focusing on traversals of the plume. The proposed Moonraker mission consists of an ESA-provided platform, with strong heritage from JUICE and Mars Sample Return, and carrying a suite of instruments dedicated to plume and surface analysis. The nominal Moonraker mission has a duration of 13.5 years. It includes a 23-flyby segment with 189 days allocated for the science phase, and can be expanded with additional segments if resources allow. The mission concept consists in investigating: i) the habitability conditions of present-day Enceladus and its internal ocean, ii) the mechanisms at play for the communication between the internal ocean and the surface of the South Polar Terrain, and iii) the formation conditions of the moon. Moonraker, thanks to state-of-the-art instruments representing a significant improvement over Cassini's payload, would quantify the abundance of key species in the plume, isotopic ratios, and physical parameters of the plume and the surface. Such a mission would pave the way for a possible future landed mission.

astro-ph.EP

Metallic magnetic calorimeter arrays for the first phase of the ECHo experiment

The ECHo experiment has been designed for the determination of the effective electron neutrino mass by means of the analysis of the end-point region of the Ho-163 electron capture spectrum. Metallic magnetic calorimeters enclosing Ho-163 are used for the high energy resolution calorimetric measurement of the Ho-163 spectrum. For the first phase of the experiment, ECHo-1k, a 72-pixel MMC array has been developed. The single-pixel design has been optimised to reach 100% stopping power for the radiation emitted in the Ho-163 electron capture process (besides the electron neutrino) and an energy resolution < 10 eV FWHM. We describe the design of the ECHo-1k detector chip, the fabrication steps and the characterisation at room temperature, at 4 K and at the final operation temperatures. In particular, a detailed analysis of the results from these tests allowed to define a quality check protocol based on parameters measurable at room temperature. We discuss the performance achieved with the two ECHo-1k detector chips - the first one with Ho-163 implanted in gold and the second one with Ho-163 implanted in silver - which have been used for the high statistics measurement of the ECHo-1k experiment. An average activity per pixel of 0.81 Bq and 0.71 Bq and an average energy resolution of 6.07 eV FWHM and 5.55 eV FWHM have been achieved with these two detectors, fulfilling the requirements for the first phase of the ECHo experiment.

physics.ins-det

Online Demodulation and Trigger for Flux-ramp Modulated SQUID Signals

Due to the periodic characteristics of SQUIDs, a suitable linearization technique is required for SQUID-based readout. Flux-ramp modulation is a common linearization technique and is typically applied for the readout of a microwave-SQUID-multiplexer as well as since recently also for dc-SQUIDs. Flux-ramp modulation requires another stage in the signal processing chain to demodulate the SQUID output signal before further processing. For cryogenic microcalorimenters, these events are given by fast exponentially rising and slowly exponentially decaying pulses which shall be detected by a trigger engine and recorded by a storage logic. Since the data rate can be decreased significantly by demodulation and event detection, it is desirable to do both steps on the deployed fast FPGA logic during measurement before passing the data to a general-purpose processor. In this contribution, we show the implementation of efficient multi-channel flux-ramp demodulation computed at run-time on a SoC-FPGA. Furthermore, a concept and implementation for an online trigger and buffer mechanism with its theoretical trigger loss rates depending on buffer size is presented. Both FPGA modules can be operated with up to 500 MHz clock frequency and can efficiently process 32 channels. Correct functionality and data reduction capability of the modules are demonstrated in measurements utilizing magnetic microcalorimeter irradiated with an Iron-55 source for event generation and read out by a microwave SQUID multiplexer.

eess.SP

Multichannel read-out for arrays of metallic magnetic calorimeters

Metallic magnetic micro-calorimeters (MMCs) operated at millikelvin temperature offer the possibility to achieve eV-scale energy resolution with high stopping power for X-rays and massive particles in an energy range up to several tens of keV. This motivates their use in a wide range of applications in fields as particle physics, atomic and molecular physics. Present detector systems consist of MMC arrays read out by 32 two-stage SQUID read-out channels. In contrast to the design of the detector array and consequently the design of the front-end SQUIDs, which need to be optimised for the physics case and the particles to be detected in a given experiment, the read-out chain can be standardised. We present our new standardised 32-channel parallel read-out for the operation of MMC arrays to be operated in a dilution refrigerator. The read-out system consists of a detector module, whose design depends on the particular application, an amplifier module, ribbon cables from room temperature to the millikelvin platform and a data acquisition system. In particular, we describe the realisation of the read-out system prepared for the ECHo-1k experiment for the operation of two 64-pixel arrays. The same read-out concept is also used for the maXs detector systems, developed for the study of the de-excitation of highly charged heavy ions by X-rays, as well as for the MOCCA system, developed for the energy and position sensitive detection of neutral molecular fragments for the study of fragmentation when molecular ions recombine with electrons. The choice of standard modular components for the operation of 32-channel MMC arrays offer the flexibility to upgrade detector modules without the need of any changes in the read-out system and the possibility to individually exchange parts in case of damages or failures.

physics.ins-det

High-resolution for IAXO: MMC-based X-ray Detectors

Axion helioscopes like the planned International Axion Observatory (IAXO) search for evidence of axions and axion-like particles (ALPs) from the Sun. A strong magnetic field is used to convert ALPs into photons via the generic ALP-photon coupling. To observe the resulting photons, X-ray detectors with low background and high efficiency are necessary. In addition, good energy resolution and low energy threshold would allow for investigating the ALP properties by studying the X-ray spectrum after its discovery. We propose to use low temperature metallic magnetic calorimeters (MMCs). Here we present the first detector system based on MMCs developed for IAXO and discuss the results of the characterization. The detector consists of a two-dimensional 64-pixel array covering an active area of 16 mm$^2$ with a fill factor of 93 %. We achieve an average energy resolution of 6.1 eV FWHM allowing for energy thresholds below 100 eV. This detector is the first step towards a larger 1 cm$^2$ array matching the IAXO X-ray optics. We determine the background rate for an unshielded detector system in the energy range between 1 keV and 10 keV to be $3.2(1) \times 10^{-4}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$ from events acquired over 30 days. In the future, active and passive shields will significantly reduce the background induced by cosmic muons and natural radioactivity. Our results demonstrate that MMCs are a promising technology for helioscopes to discover and study ALPs.

physics.ins-det

A White Paper on keV Sterile Neutrino Dark Matter

We present a comprehensive review of keV-scale sterile neutrino Dark Matter, collecting views and insights from all disciplines involved - cosmology, astrophysics, nuclear, and particle physics - in each case viewed from both theoretical and experimental/observational perspectives. After reviewing the role of active neutrinos in particle physics, astrophysics, and cosmology, we focus on sterile neutrinos in the context of the Dark Matter puzzle. Here, we first review the physics motivation for sterile neutrino Dark Matter, based on challenges and tensions in purely cold Dark Matter scenarios. We then round out the discussion by critically summarizing all known constraints on sterile neutrino Dark Matter arising from astrophysical observations, laboratory experiments, and theoretical considerations. In this context, we provide a balanced discourse on the possibly positive signal from X-ray observations. Another focus of the paper concerns the construction of particle physics models, aiming to explain how sterile neutrinos of keV-scale masses could arise in concrete settings beyond the Standard Model of elementary particle physics. The paper ends with an extensive review of current and future astrophysical and laboratory searches, highlighting new ideas and their experimental challenges, as well as future perspectives for the discovery of sterile neutrinos.

hep-ph

Cryogenic micro-calorimeters for mass spectrometric identification of neutral molecules and molecular fragments

We have systematically investigated the energy resolution of a magnetic micro-calorimeter (MMC) for atomic and molecular projectiles at impact energies ranging from $E\approx13$ to 150 keV. For atoms we obtained absolute energy resolutions down to $ΔE \approx 120$ eV and relative energy resolutions down to $ΔE/E\approx10^{-3}$. We also studied in detail the MMC energy-response function to molecular projectiles of up to mass 56 u. We have demonstrated the capability of identifying neutral fragmentation products of these molecules by calorimetric mass spectrometry. We have modeled the MMC energy-response function for molecular projectiles and conclude that backscattering is the dominant source of the energy spread at the impact energies investigated. We have successfully demonstrated the use of a detector absorber coating to suppress such spreads. We briefly outline the use of MMC detectors in experiments on gas-phase collision reactions with neutral products. Our findings are of general interest for mass spectrometric techniques, particularly for those desiring to make neutral-particle mass measurements.

physics.ins-det

First Calorimetric Measurement of OI-line in the Electron Capture Spectrum of $^{163}$Ho

The isotope $^{163}$Ho undergoes an electron capture process with a recommended value for the energy available to the decay, $Q_{\rm EC}$, of about 2.5 keV. According to the present knowledge, this is the lowest $Q_{\rm EC}$ value for electron capture processes. Because of that, $^{163}$Ho is the best candidate to perform experiments to investigate the value of the electron neutrino mass based on the analysis of the calorimetrically measured spectrum. We present for the first time the calorimetric measurement of the atomic de-excitation of the $^{163}$Dy daughter atom upon the capture of an electron from the 5s shell in $^{163}$Ho, OI-line. The measured peak energy is 48 eV. This measurement was performed using low temperature metallic magnetic calorimeters with the $^{163}$Ho ion implanted in the absorber. We demonstrate that the calorimetric spectrum of $^{163}$Ho can be measured with high precision and that the parameters describing the spectrum can be learned from the analysis of the data. Finally, we discuss the implications of this result for the Electron Capture $^{163}$Ho experiment, ECHo, aiming to reach sub-eV sensitivity on the electron neutrino mass by a high precision and high statistics calorimetric measurement of the $^{163}$Ho spectrum.

physics.ins-det