Searcharxiv⌕ Search

arXiv subjects

S. Knappe-Grüneberg

Publications and source records attributed to S. Knappe-Grüneberg.

5 recordsLinked to original sources

New Limit on the Permanent Electric Dipole Moment of $^{129}$Xe using $^{3}$He Comagnetometry and SQUID Detection

We report results of a new technique to measure the electric dipole moment of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pumping, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement campaign in 2017 and a 2.5 week campaign in 2018, combined with detailed study of systematic effects, is $d_A(^{129}\mathrm{Xe}) = (1.4 \pm 6.6_\mathrm{stat} \pm 2.0_\mathrm{syst})\times10^{-28}~e\,\mathrm{cm}$. This corresponds to an upper limit of $|d_A(^{129}\mathrm{Xe})| < 1.4 \times 10^{-27} ~e\,\mathrm{cm}~(95\%~\mathrm{CL})$, a factor of five more sensitive than the limit set in 2001.

physics.atom-ph↗

A new measurement of the permanent electric dipole moment of $^{129}$Xe using $^{3}$He comagnetometry and SQUID detection

We describe a new technique to measure the EDM of $^{129}$Xe with $^3$He comagnetometry. Both species are polarized using spin-exchange optical pumping, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result of a one week run combined with a detailed study of systematic effects is $d_A(^{129}\mathrm{Xe}) = (0.26 \pm 2.33_\mathrm{stat} \pm 0.72_\mathrm{syst})\times10^{-27}~e\,\mathrm{cm}$. This corresponds to an upper limit of $|d_A(^{129}\mathrm{Xe})| < 4.81\times 10^{-27} ~e\,\mathrm{cm}~(95\%~\mathrm{CL})$, a factor of 1.4 more sensitive than the previous limit.

physics.atom-ph↗

A magnetically shielded room with ultra low residual field and gradient

A versatile and portable magnetically shielded room with a field of (700 \pm 200) pT within a central volume of 1m x 1m x 1m and a field gradient less than 300 pT/m is described. This performance represents more than a hundred-fold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental physics at low energies; in particular, searches for electric dipole moments of fundamental systems and tests of Lorentz-invariance based on spin-precession experiments. Studies of the residual fields and their sources enable improved design of future ultra-low gradient environments and experimental apparatus.

physics.ins-det↗

Limit on Lorentz and CPT violation of the bound Neutron Using a Free Precession 3He/129Xe co-magnetometer

We report on the search for Lorentz violating sidereal variations of the frequency difference of co-located spin-species while the Earth and hence the laboratory reference frame rotates with respect to a relic background field. The co-magnetometer used is based on the detection of freely precessing nuclear spins from polarized 3He and 129Xe gas samples using SQUIDs as low-noise magnetic flux detectors. As result we can determine the limit for the equatorial component of the background field interacting with the spin of the bound neutron to be bn < 3.7 x 10^{-32} GeV (95 C.L.).

gr-qc↗

Test of Lorentz Symmetry by using a 3He/129Xe Co-Magnetometer

To test Lorentz symmetry we used a 3He/129Xe co-magnetometer. We will give a short summary of our experimental setup and the results of our latest measurements. We obtained preliminary results for the equatorial component of the background field interacting with the spin of the bound neutron: b_n < 3.72 x 10^(-32) GeV (95 C.L.).

hep-ph↗