SearcharxivSearch

arXiv subjects

S. Kovacevic

Publications and source records attributed to S. Kovacevic.

6 recordsLinked to original sources

A phase-field model for microbiologically influenced corrosion

A phase-field-based reaction-diffusion corrosion model is developed to predict microbially influenced corrosion (MIC) in metal alloys, with a focus on anaerobic conditions and sulfate-reducing bacteria (SRB). The formulation couples microbial sulfate reduction, sulfate transport, electrochemical kinetics, material dissolution, and mechanical effects. Microbial activity is modelled using a Monod-type expression for sulfate consumption, whereas the mechano-chemical coupling is incorporated through an enhanced mobility relationship that captures the influence of mechanical fields on corrosion kinetics. The model is calibrated against experiments and shows strong agreement in predicting pitting kinetics under SRB activity. Sensitivity analyses quantify the competing roles of microbial kinetics, transport, and thermodynamic driving forces in governing corrosion behaviour. The capability of the formulation to capture both MIC-induced pitting and stress-assisted corrosion across multiple length scales is demonstrated through case studies that include microstructure-sensitive simulations and structural-scale coupling with a cathodic protection (CP) model. Results show that finer grain sizes reduce pitting severity but promote faster defect propagation under mechanical loading. At the structural scale, coupling with the CP model enables predictions of defect growth under varying electrochemical conditions and over engineering-relevant length scales, as exemplified with the analysis of an offshore wind turbine monopile. CP delays pitting and suppresses crack propagation, although its effectiveness diminishes as sacrificial anodes degrade. The framework provides a predictive and computationally efficient tool for assessing MIC-induced damage over extended times, with potential applications in the integrity and life assessment of metallic structures operating in aggressive microbial environments.

cs.CE

A mesoscale phase-field model of intergranular liquid lithium corrosion of ferritic/martensitic steels

A phase-field model is developed to simulate intergranular corrosion of ferritic/martensitic steels exposed to liquid lithium. The chromium concentration of the material is used to track the mass transport within the metal and liquid (corrosive) phase. The framework naturally captures intergranular corrosion by enhancing the diffusion of chromium along grain boundaries relative to the grain bulk with no special treatment for the corrosion front evolution. The formulation applies to arbitrary 2D and 3D polycrystalline geometries. The framework reproduces experimental measurements of weight loss and corrosion depth for a 9 wt\% Cr ferritic/martensitic steel exposed to static lithium at 600 $^\circ$C. A sensitivity analysis, varying near-surface grain density, grain size, and chromium depletion thickness, highlights the microstructural influence in the corrosion process. Moreover, the significance of saturation is considered and evaluated. Simulation results show that near-surface grain density is a deciding factor, whereas grain size dictates the susceptibility to intergranular corrosion.

physics.chem-ph

Impact of pH and chloride content on the biodegradation of magnesium alloys for medical implants: An in vitro and phase-field study

The individual contributions of pH and chloride concentration to the corrosion kinetics of bioabsorbable magnesium (Mg) alloys remain unresolved despite their significant roles as driving factors in Mg corrosion. This study demonstrates and quantifies hitherto unknown separate effects of pH and chloride content on the corrosion of Mg alloys pertinent to biomedical implant applications. The experimental setup designed for this purpose enables the quantification of the dependence of corrosion on pH and chloride concentration. The in vitro tests conclusively demonstrate that variations in chloride concentration, relevant to biomedical applications, have a negligible effect on corrosion kinetics. The findings identify pH as a critical factor in the corrosion of bioabsorbable Mg alloys. A variationally consistent phase-field model is developed for assessing the degradation of Mg alloys in biological fluids. The model accurately predicts the corrosion performance of Mg alloys observed during the experiments, including their dependence on pH and chloride concentration. The capability of the framework to account for mechano-chemical effects during corrosion is demonstrated in practical orthopaedic applications considering bioabsorbable Mg alloy implants for bone fracture fixation and porous scaffolds for bone tissue engineering. The strategy has the potential to assess the in vitro and in vivo service life of bioabsorbable Mg-based biomedical devices.

physics.med-ph

A nonlinear phase-field model of corrosion with charging kinetics of electric double layer

A nonlinear phase-field model is developed to simulate corrosion damage. The motion of the electrode$-$ electrolyte interface follows the usual kinetic rate theory for chemical reactions based on the Butler-Volmer equation. The model links the surface polarization variation associated with the charging kinetics of an electric double layer (EDL) to the mesoscale transport. The effects of the EDL are integrated as a boundary condition on the solution potential equation. The boundary condition controls the magnitude of the solution potential at the electrode-electrolyte interface. The ion concentration field outside the EDL is obtained by solving the electro-diffusion equation and Ohm's law for the solution potential. The model is validated against the classic benchmark pencil electrode test. The framework developed reproduces experimental measurements of both pit kinetics and transient current density response. The model enables more accurate information on corrosion damage, current density, and environmental response in terms of the distribution of electric potential and charged species. The sensitivity analysis for different properties of the EDL is performed to investigate their role in the electrochemical response of the system. Simulation results show that the properties of the EDL significantly influence the transport of ionic species in the electrolyte.

physics.chem-ph

A microstructure-sensitive electro-chemo-mechanical phase-field model of pitting and stress corrosion cracking

An electro-chemo-mechanical phase-field formulation is developed to simulate pitting and stress corrosion in polycrystalline materials. The formulation incorporates dependencies of mechanical properties and corrosion potential on crystallographic orientation. The model considers the formation and charging dynamics of an electric double layer through a new general boundary condition for the solution potential. The potential of the model is demonstrated by simulating corrosion in polycrystalline materials with various grain morphology distributions. The results show that incorporating the underlying microstructure yields more extensive defects, faster defect kinetics, and irregular pit and crack shapes relative to a microstructurally-insensitive homogeneous material scenario.

cs.CE

Phase-field modeling of pitting and mechanically-assisted corrosion of Mg alloys for biomedical applications

A phase-field model is developed to simulate the corrosion of Mg alloys in body fluids. The model incorporates both Mg dissolution and the transport of Mg ions in solution, naturally predicting the transition from activation-controlled to diffusion-controlled bio-corrosion. In addition to uniform corrosion, the presented framework captures pitting corrosion and accounts for the synergistic effect of aggressive environments and mechanical loading in accelerating corrosion kinetics. The model applies to arbitrary 2D and 3D geometries with no special treatment for the evolution of the corrosion front, which is described using a diffuse interface approach. Experiments are conducted to validate the model and a good agreement is attained against in vitro measurements on Mg wires. The potential of the model to capture mechano-chemical effects during corrosion is demonstrated in case studies considering Mg wires in tension and bioabsorbable coronary Mg stents subjected to mechanical loading. The proposed methodology can be used to assess the in vitro and in vivo service life of Mg-based biomedical devices and optimize the design taking into account the effect of mechanical deformation on the corrosion rate. The model has the potential to advocate further development of Mg alloys as a biodegradable implant material for biomedical applications.

physics.med-ph