SearcharxivSearch

arXiv subjects

S. Kuroyanagi

Publications and source records attributed to S. Kuroyanagi.

15 recordsLinked to original sources

Decadal upgrade strategy for KAGRA toward post-O5 gravitational-wave astronomy

The KAGRA Collaboration has investigated a ten-year upgrade strategy for the KAGRA gravitational wave detector, considering a total of 14 upgrade options that vary in mirror mass, quantum noise reduction techniques, and the quality of cryogenic suspensions. We evaluated the scientific potential of these configurations with a focus on key targets such as parameter estimation of compact binary coalescences, binary neutron star post-merger signals, and continuous gravitational waves. Rather than aiming to improve all science cases uniformly, we prioritized those most sensitive to the detector configuration. Technical feasibility was assessed based on required hardware developments, associated R\&D efforts, cost, and risk. Our study finds that a high-frequency upgrade plan that enhances sensitivity over a broad frequency range above ~200 Hz offers the best balance between scientific return and technical feasibility. Such an upgrade would enable sky localization of binary neutron star mergers at 100 Mpc to better than 0.5 deg$^2$ in a LIGO-Virgo-KAGRA network, and improve the measurement precision of tidal deformability parameter by approximately 10% at median, compared to a network without KAGRA.

gr-qc

Identification of Noise-Associated Glitches in KAGRA O3GK with Hveto

Transient noise ("glitches") in gravitational wave detectors can mimic or obscure true signals, significantly reducing detection sensitivity. Identifying and excluding glitch-contaminated data segments is therefore crucial for enhancing the performance of gravitational-wave searches. We perform a noise analysis of the KAGRA data obtained during the O3GK observation. Our analysis is performed with hierarchical veto (Hveto) which identifies noises based on the statistical time correlation between the main channel and the auxiliary channels. A total of 2,531 noises were vetoed by 28 auxiliary channels with the configuration (i.e., signal-to-noise threshold set to 8) that we chose for Hveto. We identify vetoed events as glitches on the spectrogram via visual examination after plotting them with Q-transformation. By referring to the Gravity Spy project, we categorize 2,354 glitches into six types: blip, helix, scratchy, and scattered light, which correspond to those listed in Gravity Spy, and dot and line, which are not found in the Gravity Spy classification and are thus named based on their spectrogram morphology in KAGRA data. The remaining 177 glitches are determined not to belong to any of these six types. We show how the KAGRA glitch types are related to each subsystem of KAGRA. To investigate the possible correlation between the main channel and the round winner - an auxiliary channel statistically associated with the main channel for vetoing purposes - we visually examine the similarity or difference in the glitch pattern on the spectrogram. We compare the qualitative correlation found through visual examination with coherence, which is known to provide quantitative measurement for the correlation between the main channel and each auxiliary channel. Our comprehensive noise analysis will help improve the data quality of KAGRA by applying it to future KAGRA observation data.

gr-qc

Input optics systems of the KAGRA detector during O3GK

KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensity and frequency stabilization systems, modulators, a Faraday isolator, mode-matching telescopes, and a high-power beam dump. These optics were successfully delivered to the KAGRA interferometer and operated stably during the observations. The laser frequency noise was observed to limit the detector sensitivity above a few kHz, whereas the laser intensity did not significantly limit the detector sensitivity.

gr-qc

Noise subtraction from KAGRA O3GK data using Independent Component Analysis

In April 2020, KAGRA conducted its first science observation in combination with the GEO~600 detector (O3GK) for two weeks. According to the noise budget estimation, suspension control noise in the low frequency band and acoustic noise in the middle frequency band are identified as the dominant contribution. In this study, we show that such noise can be reduced in offline data analysis by utilizing a method called Independent Component Analysis (ICA). Here the ICA model is extended from the one studied in iKAGRA data analysis by incorporating frequency dependence while linearity and stationarity of the couplings are still assumed. By using optimal witness sensors, those two dominant contributions are mitigated in the real observational data. We also analyze the stability of the transfer functions for whole two weeks data in order to investigate how the current subtraction method can be practically used in gravitational wave search.

astro-ph.IM

Quantum gravity phenomenology at the dawn of the multi-messenger era -- A review

The exploration of the universe has recently entered a new era thanks to the multi-messenger paradigm, characterized by a continuous increase in the quantity and quality of experimental data that is obtained by the detection of the various cosmic messengers (photons, neutrinos, cosmic rays and gravitational waves) from numerous origins. They give us information about their sources in the universe and the properties of the intergalactic medium. Moreover, multi-messenger astronomy opens up the possibility to search for phenomenological signatures of quantum gravity. On the one hand, the most energetic events allow us to test our physical theories at energy regimes which are not directly accessible in accelerators; on the other hand, tiny effects in the propagation of very high energy particles could be amplified by cosmological distances. After decades of merely theoretical investigations, the possibility of obtaining phenomenological indications of Planck-scale effects is a revolutionary step in the quest for a quantum theory of gravity, but it requires cooperation between different communities of physicists (both theoretical and experimental). This review is aimed at promoting this cooperation by giving a state-of-the art account of the interdisciplinary expertise that is needed in the effective search of quantum gravity footprints in the production, propagation and detection of cosmic messengers.

hep-ph

Performance of the KAGRA detector during the first joint observation with GEO 600 (O3GK)

KAGRA, the kilometer-scale underground gravitational-wave detector, is located at Kamioka, Japan. In April 2020, an astrophysics observation was performed at the KAGRA detector in combination with the GEO 600 detector; this observation operation is called O3GK. The optical configuration in O3GK is based on a power recycled Fabry-Pérot Michelson interferometer; all the mirrors were set at room temperature. The duty factor of the operation was approximately 53%, and the strain sensitivity was $3\times10^{-22}~/\sqrt{\rm{Hz}}$ at 250 Hz. In addition, the binary-neutron-star (BNS) inspiral range was approximately 0.6 Mpc. The contributions of various noise sources to the sensitivity of O3GK were investigated to understand how the observation range could be improved; this study is called a "noise budget". According to our noise budget, the measured sensitivity could be approximated by adding up the effect of each noise. The sensitivity was dominated by noise from the sensors used for local controls of the vibration isolation systems, acoustic noise, shot noise, and laser frequency noise. Further, other noise sources that did not limit the sensitivity were investigated. This paper provides a detailed account of the KAGRA detector in O3GK including interferometer configuration, status, and noise budget. In addition, strategies for future sensitivity improvements such as hardware upgrades, are discussed.

astro-ph.IM

Overview of KAGRA: Calibration, detector characterization, physical environmental monitors, and the geophysics interferometer

KAGRA is a newly built gravitational wave observatory, a laser interferometer with a 3 km arm length, located in Kamioka, Gifu, Japan. In this series of articles, we present an overview of the baseline KAGRA, for which we finished installing the designed configuration in 2019. This article describes the method of calibration (CAL) used for reconstructing gravitational wave signals from the detector outputs, as well as the characterization of the detector (DET). We also review the physical environmental monitors (PEM) system and the geophysics interferometer (GIF). Both are used for characterizing and evaluating the data quality of the gravitational wave channel. They play important roles in utilizing the detector output for gravitational wave searches. These characterization investigations will be even more important in the near future, once gravitational wave detection has been achieved, and in using KAGRA in the gravitational wave astronomy era.

gr-qc

Searching for gravitational wave bursts from cosmic string cusps with the Parkes Pulsar Timing Array

Cosmic strings are potential gravitational wave (GW) sources that can be probed by pulsar timing arrays (PTAs). In this work we develop a detection algorithm for a GW burst from a cusp on a cosmic string, and apply it to Parkes PTA data. We find four events with a false alarm probability less than 1%. However further investigation shows that all of these are likely to be spurious. As there are no convincing detections we place upper limits on the GW amplitude for different event durations. From these bounds we place limits on the cosmic string tension of G mu ~ 10^{-5}, and highlight that this bound is independent from those obtained using other techniques. We discuss the physical implications of our results and the prospect of probing cosmic strings in the era of Square Kilometre Array (SKA).

gr-qc

Overview of KAGRA : KAGRA science

KAGRA is a newly build gravitational-wave observatory, a laser interferometer with 3 km arm length, located in Kamioka, Gifu, Japan. In this paper in the series of KAGRA-featured articles, we discuss the science targets of KAGRA projects, considering not only the baseline KAGRA (current design) but also its future upgrade candidates (KAGRA+) for the near to middle term (~5 years).

gr-qc

Overview of KAGRA: Detector design and construction history

KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA finished all installations with the designed configuration, which we call the baseline KAGRA. In this occasion, we present an overview of the baseline KAGRA from various viewpoints in a series of of articles. In this article, we introduce the design configurations of KAGRA with its historical background.

physics.ins-det

Application of the independent component analysis to the iKAGRA data

We apply the independent component analysis (ICA) to the real data from a gravitational wave detector for the first time. Specifically we use the iKAGRA data taken in April 2016, and calculate the correlations between the gravitational wave strain channel and 35 physical environmental channels. Using a couple of seismic channels which are found to be strongly correlated with the strain, we perform ICA. Injecting a sinusoidal continuous signal in the strain channel, we find that ICA recovers correct parameters with enhanced signal-to-noise ratio, which demonstrates usefulness of this method. Among the two implementations of ICA used here, we find the correlation method yields the optimal result for the case environmental noises act on the strain channel linearly.

astro-ph.IM

An arm length stabilization system for KAGRA and future gravitational-wave detectors

Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, which is compatible with the interferometers having long arms like the next generation GW detectors. The features of the new ALS are that the control configuration is simpler than those of previous ones and that it is not necessary to lay optical fibers for the ALS along the kilometer-long arms of the detector. Along with simulations of its noise performance, an experimental test of the new ALS was performed utilizing a single arm cavity of KAGRA. This paper presents the first results of the test where we demonstrated that lock acquisition of the arm cavity was achieved using the new ALS and residual noise was measured to be $8.2\,\mathrm{Hz}$ in units of frequency, which is smaller than the linewidth of the arm cavity and thus low enough to lock the full interferometer of KAGRA in a repeatable and reliable manner.

physics.ins-det

First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA

KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic motion at low frequencies and high stability of the detector. Another advantage is that it cools down the sapphire test mass mirrors to cryogenic temperatures to reduce thermal noise. In April-May 2018, we have operated a 3-km Michelson interferometer with a cryogenic test mass for 10 days, which was the first time that km-scale interferometer was operated at cryogenic temperatures. In this article, we report the results of this "bKAGRA Phase 1" operation. We have demonstrated the feasibility of 3-km interferometer alignment and control with cryogenic mirrors.

astro-ph.IM

Vibration isolation system with a compact damping system for power recycling mirrors of KAGRA

A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main stages allows for achieving sufficient damping performance with a simple feedback as well as vibration isolation ratio. Three Type-Bp systems were installed in KAGRA, and were proved to satisfy the requirements on the damping performance, and also on estimated residual displacement of the optics.

physics.ins-det

KAGRA: 2.5 Generation Interferometric Gravitational Wave Detector

The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Telescope), a new GW detector with two 3-km baseline arms arranged in the shape of an "L", located inside the Mt. Ikenoyama, Kamioka, Gifu, Japan. KAGRA's design is similar to those of the second generations such as Advanced LIGO/Virgo, but it will be operating at the cryogenic temperature with sapphire mirrors. This low temperature feature is advantageous for improving the sensitivity around 100 Hz and is considered as an important feature for the third generation GW detector concept (e.g. Einstein Telescope of Europe or Cosmic Explorer of USA). Hence, KAGRA is often called as a 2.5 generation GW detector based on laser interferometry. The installation and commissioning of KAGRA is underway and its cryogenic systems have been successfully tested in May, 2018. KAGRA's first observation run is scheduled in late 2019, aiming to join the third observation run (O3) of the advanced LIGO/Virgo network. In this work, we describe a brief history of KAGRA and highlights of main feature. We also discuss the prospects of GW observation with KAGRA in the era of O3. When operating along with the existing GW detectors, KAGRA will be helpful to locate a GW source more accurately and to determine the source parameters with higher precision, providing information for follow-up observations of a GW trigger candidate.