SearcharxivSearch

arXiv subjects

S. L. Watkins

Publications and source records attributed to S. L. Watkins.

At least 19 recordsLinked to original sources

SPLENDOR: a novel detector platform to search for light dark matter with narrow-gap semiconductors

We present the design and current status of SPLENDOR, a novel detector platform that combines narrow-gap semiconductor targets with low-noise charge readout to achieve sensitivity to dark matter energy deposits well below the eV scale. SPLENDOR is designed to be a modular and scalable system able to accommodate different target materials and signal readout technologies. SPLENDOR's present strategy entails: (i) the use of strongly correlated f-electron semiconductors with anisotropic electronic structures to enable not only sub-eV energy thresholds, but also directional sensitivity to the incoming dark matter flux, allowing for signal-background discrimination via daily modulation, and (ii) custom charge readout based on cryogenic high-electron-mobility transistor (cryoHEMT) amplifiers approaching single-electron resolution. We report on the selection and characterization of Eu$_5$In$_2$Sb$_6$ as the target material for SPLENDOR's first prototype detector, as well as the development and calibration of the prototype amplifier chain, achieving a measured charge resolution of 20$\pm$7 electrons in silicon test samples, consistent with predicted performance. This provides a demonstration of the detector architecture, which is now ready for deployment in a dark matter search campaign to deliver SPLENDOR's first science results. Finally, we present estimates of sensitivity reach in the parameter space of athermally produced relic dark matter under high- and low-background environments, and for various amplifier technology upgrades with increasing performance, including planned quantum sensing upgrades in order to achieve our ultimate goal of sub-electron resolution in optimized systems. SPLENDOR provides a novel approach to dark matter direct detection, combining quantum sensing with material's design to open new avenues of exploration in the sub-MeV mass range of dark matter parameter space.

physics.ins-det

Rare multi-nucleon decays with the full data sets of the Majorana Demonstrator

The Majorana Demonstrator was an ultra-low-background experiment designed for neutrinoless double-beta decay ($0νββ$) investigation in $^{76}$Ge. Located at the Sanford Underground Research Facility in Lead, South Dakota, the Demonstrator utilized modular high-purity Ge detector arrays within shielded vacuum cryostats, operating deep underground. The arrays, with a capacity of up to 40.4 kg (27.2 kg enriched to $\sim 88\%$ in $^{76}$Ge), have accumulated the full data set, totaling 64.5 kg yr of enriched active exposure and 27.4 kg yr of exposure for natural detectors. Our updated search improves previously explored three-nucleon decay modes in Ge isotopes, setting new partial lifetime limits of $1.83\times10^{26}$ years (90\% confidence level) for $^{76}$Ge($ppp$) $\rightarrow$ $^{73}$Cu e$^+π^+π^+$ and $^{76}$Ge($ppn$) $\rightarrow$ $^{73}$Zn e$^+π^+$. The partial lifetime limit for the fully inclusive tri-proton decay mode of $^{76}$Ge is found to be $2.1\times10^{25}$ yr. Furthermore, we have updated limits for corresponding multi-nucleon decays.

nucl-ex

Final Results of the MAJORANA DEMONSTRATOR's Search for Double-Beta Decay of $^{76}$Ge to Excited States of $^{76}$Se

$^{76}$Ge can $ββ$ decay into three possible excited states of $^{76}$Se, with the emission of two or, if the neutrino is Majorana, zero neutrinos. None of these six transitions have yet been observed. The MAJORANA DEMONSTRATOR was designed to study $ββ$ decay of $^{76}$Ge using a low background array of high purity germanium detectors. With 98.2 kg-y of isotopic exposure, the DEMONSTRATOR sets the strongest half-life limits to date for all six transition modes. For $2νββ$ to the $0^+_1$ state of $^{76}$Se, this search has begun to probe for the first time half-life values predicted using modern many-body nuclear theory techniques, setting a limit of $T_{1/2}>1.5\times10^{24}$ y (90% CL).

nucl-ex

First Limits on Light Dark Matter Interactions in a Low Threshold Two Channel Athermal Phonon Detector from the TESSERACT Collaboration

We present results of a search for spin-independent dark matter-nucleon interactions in a 1 cm$^2$ by 1 mm thick (0.233 gram) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves a r.m.s. baseline energy resolution of 361.5 $\pm$ 0.4 MeV/$c^2$, the best for any athermal phonon detector to date. With an exposure of 0.233g $\times$ 12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 MeV/$c^2$, with the lowest unexplored cross section of 4 $\times 10^{-32}$ cm$^2$ at 87 MeV/$c^2$. We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low-energy backgrounds that are coupled to individual sensors.

hep-ex

First Demonstration of the HeRALD Superfluid Helium Detector Concept

The SPICE/HeRALD collaboration is performing R&D to enable studies of sub-GeV dark matter models using a variety of target materials. Here we report our recent progress on instrumenting a superfluid $^4$He target mass with a transition-edge sensor based calorimeter to detect both atomic signals (scintillation) and $^4$He quasiparticle (phonon and roton) excitations. The sensitivity of HeRALD to the critical "quantum evaporation" signal from $^4$He quasiparticles requires us to block the superfluid film flow to the calorimeter. We have developed a heat-free film-blocking method employing an unoxidized Cs film, which we implemented in a prototype "HeRALD v0.1" detector of ~10 g target mass. This article reports initial studies of the atomic and quasiparticle signal channels. A key result of this work is the measurement of the quantum evaporation channel's gain of 0.15 $\pm$ 0.01, which will enable $^4$He-based dark matter experiments in the near term. With this gain the HeRALD detector reported here has an energy threshold of 145 eV at 5 sigma, which would be sensitive to dark matter masses down to 220 MeV/c$^2$.

physics.ins-det

Design Studies Of A Pulsed Quasimonoenergetic 2-keV Neutron Source For Calibration Of Low Threshold Dark Matter Detectors

We describe design studies for a pulsed quasi-monoenergetic 2-keV neutron source for calibration of sub-keV nuclear recoils. Such a calibration is required for detectors sensitive to sub-GeV dark matter and also the coherent elastic scattering of reactor neutrinos. In our design, neutrons from a commercial deuterium-tritium generator are moderated to the keV scale and then filtered to the monoenergetic spectrum using a feature in the neutron cross section of scandium. In this approach, unmoderated high-energy neutrons form a challenging background, along with gammas from neutron capture in the moderator materials. We describe the optimization of the moderator+filter and shielding geometry, and find a geometry that in simulation achieves both the target neutron flux at 2 keV and subdominant rates of background interactions. Lastly, we describe a future path to lower-energy (few eV scale) calibrations using time-of-flight and sub-keV neutrons.

physics.ins-det

An assay-based background projection for the MAJORANA DEMONSTRATOR using Monte Carlo Uncertainty Propagation

The background index is an important quantity which is used in projecting and calculating the half-life sensitivity of neutrinoless double-beta decay ($0νββ$) experiments. A novel analysis framework is presented to calculate the background index using the specific activities, masses and simulated efficiencies of an experiment's components as distributions. This Bayesian framework includes a unified approach to combine specific activities from assay. Monte Carlo uncertainty propagation is used to build a background index distribution from the specific activity, mass and efficiency distributions. This analysis method is applied to the MAJORANA DEMONSTRATOR, which deployed arrays of high-purity Ge detectors enriched in $^{76}$Ge to search for $0νββ$. The framework projects a mean background index of $\left[8.95 \pm 0.36\right] \times 10^{-4}$cts/(keV kg yr) from $^{232}$Th and $^{238}$U in the DEMONSTRATOR's components.

nucl-ex

Two-Stage Cryogenic HEMT Based Amplifier For Low Temperature Detectors

To search for dark matter candidates with masses below $\mathcal{O}$(MeV), the SPLENDOR (Search for Particles of Light dark mattEr with Narrow-gap semiconDuctORs) experiment is developing novel narrow-bandgap semiconductors with electronic bandgaps on the order of 1-100 meV. In order to detect the charge signal produced by scattering or absorption events, SPLENDOR has designed a two-stage cryogenic HEMT-based amplifier with an estimated charge resolution approaching the single-electron level. A low-capacitance ($\sim$1.6 pF) HEMT is used as a buffer stage at $T=10\,\mathrm{mK}$ to mitigate effects of stray capacitance at the input. The buffered signal is then amplified by a higher-capacitance ($\sim$200 pF) HEMT amplifier stage at $T=4\,\mathrm{K}$. Importantly, the design of this amplifier makes it usable with any insulating material - allowing for rapid prototyping of a variety of novel detector materials. We present the two-stage cryogenic amplifier design, preliminary voltage noise performance, and estimated charge resolution of 7.2 electrons.

physics.ins-det

SPLENDAQ: A Detector-Agnostic Data Acquisition System for Small-Scale Physics Experiments

Many scientific applications from rare-event searches to condensed matter system characterization to high-rate nuclear experiments require time-domain triggering on a raw stream of data, where the triggering is generally threshold-based or randomly acquired. When carrying out detector R&D, there is a need for a general data acquisition (DAQ) system to quickly and efficiently process such data. In the SPLENDOR collaboration, we are developing the Python-based SPLENDAQ package for this exact purpose - it offers two main features for offline analysis of continuous data: a threshold-triggering algorithm based on the time-domain optimal filter formalism and an algorithm for randomly choosing nonoverlapping segments for noise measurements. Combined with the commercially available Moku platform, developed by Liquid Instruments, we have a full pipeline of event building off raw data with minimal setup. Here, we review the underlying principles of this detector-agnostic DAQ package and give concrete examples of its utility in various applications.

physics.ins-det

Majorana Demonstrator Data Release for AI/ML Applications

The enclosed data release consists of a subset of the calibration data from the Majorana Demonstrator experiment. Each Majorana event is accompanied by raw Germanium detector waveforms, pulse shape discrimination cuts, and calibrated final energies, all shared in an HDF5 file format along with relevant metadata. This release is specifically designed to support the training and testing of Artificial Intelligence (AI) and Machine Learning (ML) algorithms upon our data. This document is structured as follows. Section I provides an overview of the dataset's content and format; Section II outlines the location of this dataset and the method for accessing it; Section III presents the NPML Machine Learning Challenge associated with this dataset; Section IV contains a disclaimer from the Majorana collaboration regarding the use of this dataset; Appendix A contains technical details of this data release. Please direct questions about the material provided within this release to liaobo77@ucsd.edu (A. Li).

cs.LG

Constraints on the decay of $^{180m}$Ta

$^{180m}$Ta is a rare nuclear isomer whose decay has never been observed. Its remarkably long lifetime surpasses the half-lives of all other known $β$ and electron capture decays due to the large K-spin differences and small energy differences between the isomeric and lower energy states. Detecting its decay presents a significant experimental challenge but could shed light on neutrino-induced nucleosynthesis mechanisms, the nature of dark matter and K-spin violation. For this study, we repurposed the MAJORANA DEMONSTRATOR, an experimental search for the neutrinoless double-beta decay of $^{76}$Ge using an array of high-purity germanium detectors, to search for the decay of $^{180m}$Ta. More than 17 kilograms, the largest amount of tantalum metal ever used for such a search was installed within the ultra-low background detector array. In this paper we present results from the first year of Ta data taking and provide an updated limit for the $^{180m}$Ta half-life on the different decay channels. With new limits up to 1.5 x $10^{19}$ years, we improved existing limits by one to two orders of magnitude. This result is the most sensitive search for a single $β$ and electron capture decay ever achieved.

nucl-ex

A portable and high intensity 24 keV neutron source based on $^{124}$Sb-$^{9}$Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the $^{124}$Sb-$^9$Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from $^{124}$Sb decays while letting through the neutrons. To increase the $^{124}$Sb activity and thus the neutron flux, a $>$1 GBq $^{124}$Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20-25 keV to be 5.36$\pm$0.20 neutrons per cm$^2$ per second and the total gamma flux to be 213$\pm$6 gammas per cm$^2$ per second (numbers scaled to 1 GBq activity of the $^{124}$Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

physics.ins-det

Scintillation yield from electronic and nuclear recoils in superfluid $^4$He

Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185 keV$_\mathrm{ee}$, yielding a mean signal size of $1.25^{+0.03}_{-0.03}$~phe/keV$_\mathrm{ee}$, and nuclear recoils from 53.2 to 1090 keV$_\mathrm{nr}$. We compare the results of our relative scintillation yield measurements to an existing semiempirical model based on helium-helium and electron-helium interaction cross sections. We also study the behavior of delayed scintillation components as a function of recoil type and energy, a further avenue for signal discrimination in superfluid $^4$He.

physics.ins-det

A backing detector for order-keV neutrons

We have designed and tested a large-area (0.15~m$^2$) neutron detector based on neutron capture on \ce{^{6}Li}. The neutron detector design has been optimized for the purpose of tagging the scattering angle of keV-scale neutrons. These neutron detectors would be employed to calibrate the low-energy ($<$100 eV) nuclear recoil in detectors for dark matter and coherent elastic neutrino nucleus scattering (CE$ν$NS). We describe the design, construction, and characterization of a prototype. The prototype is designed to have a tagging efficiency of $\sim$25\% at the relevant $\mathcal{O}$(keV) neutron energies, and with a mean capture time of $\sim$17$~μ$s. The prototype was characterized using a \ce{^{252}Cf} neutron source and agreement with the simulation was observed within a few percent level.

physics.ins-det

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive 1-gram Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2)~eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100~V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2~eV threshold with a trigger rate of the order of 20~Hz. The detector's energy scale is calibrated up to 120~keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

physics.ins-det

Constraints on dark photons and axion-like particles from SuperCDMS Soudan

We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.

hep-ex

Performance of a Large Area Photon Detector For Rare Event Search Applications

We present the design and characterization of a large-area Cryogenic PhotoDetector (CPD) designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a $45.6$ $\mathrm{cm}^2$ surface area by 1-mm-thick $10.6$ $\mathrm{g}$ Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-assisted Electrothermal feedback Transition-edge sensors (QETs) with superconducting critical temperature $T_c=41.5$ $\mathrm{mK}$ to measure athermal phonons released from interactions with photons. The detector is characterized and calibrated with a collimated $^{55}$Fe X-ray source incident on the center of the detector. The noise equivalent power is measured to be $1\times 10^{-17}$ $\mathrm{W}/\sqrt{\mathrm{Hz}}$ in a bandwidth of $2.7$ $\mathrm{kHz}$. The baseline energy resolution is measured to be $σ_E = 3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.23}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$ (RMS). The detector also has an expected timing resolution of $σ_t = 2.3$ $μ\mathrm{s}$ for $5$ $σ_E$ events.

physics.ins-det

Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.

astro-ph.CO