SearcharxivSearch

arXiv subjects

S. Longo

Publications and source records attributed to S. Longo.

17 recordsLinked to original sources

A New High-Intensity Source for Ultracold Neutrons

The TRIUMF UltraCold Advanced Neutron (TUCAN) collaboration has completed a new superthermal source for ultracold neutrons (UCNs) at TRIUMF. It uses neutrons from a spallation target driven by TRIUMF's %520-MeV main cyclotron. Heavy water and liquid deuterium serve as neutron moderators, and inelastic scattering inside superfluid $^4$He at around \qty{1.1}{\kelvin} slows the neutrons down to become ultracold. During commissioning runs with the completed source, including the deuterium moderator, up to $1.47(2)\times 10^7$ UCNs were detected in the experimental area after irradiating the target and accumulating UCNs in the source for \qty{60}{\second}. Up to \qty{6.75(3)e5} UCN/s were detected during continuous operation, more than at any other source in the world.

physics.ins-det

Ultracold Neutron Guide-Coating Facility at U.Winnipeg

We report the construction and commissioning of a new ultracold neutron (UCN) guide-coating facility at the University of Winnipeg. The facility employs pulsed laser deposition (PLD) to produce diamond-like carbon (DLC) coatings on cylindrical UCN guides up to 1 m in length with a 200 mm outer diameter. DLC is a promising material for UCN transport and storage due to its high real component of the optical potential, low neutron absorption cross section, and low depolarization probabilities. First coating attempts on a full length aluminum UCN guide and matching blank flange were successfully coated with a carbon film with density of 2.3 g/cm$^3$, corresponding to optical potentials of 200 neV, as measured by X-ray reflectometry (XRR). Coating thicknesses were measured to be 90 nm for the UCN guide and 180 nm for the flange with no evidence of delamination. The implementation of a plasma plume collimator and plasma feed back control via a time of flight in vacuum ion probe produced a film with an XRR measured density of 2.8 g/cm$^3$, corresponding to an optical potential of 240 neV. This 80 nm thick film had poor adhesion to the aluminum tube substrate. These results establish a baseline for the coating facility. Ongoing and future work focuses on improving the diamond content of films and adhesion through plasma plume collimation, TOF ion probe feed back, and pre/post treatment methods with the goal of providing high quality DLC UCN guides for the TUCAN experiment at TRIUMF.

physics.ins-det

Initial results of the TRIUMF ultracold advanced neutron source

We report the first results on ultracold neutron production from a new spallation-driven superfluid $^4$He (He-II) source at TRIUMF, which is being prepared for a new, precise measurement of the neutron electric dipole moment. A total of $(9.3 \pm 0.8)\times 10^{5}$ ultracold neutrons were observed at a proton beam current of \SI{37}{\uA}, when the target was irradiated for a period of \SI{60}{\s}. The results are in fair agreement with expectations based on a detailed simulation of neutron transport and ultracold neutron source cryogenics. There is some indication that the new source might not be as limited by the conduction of heat through the He-II as originally expected. The results indicate that the source is likely to make its ultimate production goals, once the liquid deuterium cold moderator system is completed, with the expectation that $5.7\times 10^7$~UCNs would be detected in the same experiment with full liquid levels. This would, for example, correspond to delivery of $1.4\times 10^6$~UCNs delivered to each of two nEDM measurement cells, and a statistical uncertainty of $1\times 10^{-27}~e$cm on the neutron EDM in 280 days of running.

nucl-ex

Neutron EDM Experiment with an Advanced Ultracold Neutron Source at TRIUMF

The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has been developing a high-intensity ultracold neutron (UCN) source aimed at searching for the neutron electric dipole moment (EDM) with a sensitivity goal of $10^{-27}\ e{\rm cm}$. This article reports on recent progress in commissioning of the UCN source and in the development of the neutron EDM spectrometer. In its final configuration, the accelerator-driven super-thermal UCN source will enable a neutron EDM experiment with two orders of magnitude improved statistics compared to the current best experiment. Substantial progress in 2024 allowed the collaboration to operate the complete source system, with the exception of the liquid deuterium cold moderator, resulting in the first production of UCNs. The status of the EDM spectrometer is also presented, with emphasis on UCN handling components and magnetic subsystems relevant to field control, shielding, and magnetometry.

physics.ins-det

Cryogenic systems for the TUCAN EDM experiment

The TUCAN (TRIUMF UltraCold Advanced Neutron) Collaboration is completing a new ultracold neutron (UCN) source. The UCN source will deliver UCNs to a neutron electric dipole moment (EDM) experiment. The EDM experiment is projected to be capable of an uncertainty of $1\times 10^{-27}~e$cm, competitive with other planned projects, and a factor of ten more precise than the present world's best. The TUCAN source is based on a UCN production volume of superfluid helium (He-II), held at 1~K, and coupled to a proton-driven spallation target. The production rate in the source is expected to be in excess of $10^7$~UCN/s; since UCN losses can be small in superfluid helium, this should allow us to build up a large number of UCNs. The spallation-driven superfluid helium technology is the principal aspect making the TUCAN project unique. The superfluid production volume was recently cooled, for the first time, and successfully filled with superfluid helium. The design principles of the UCN source are described, along with some of the challenging cryogenic milestones that were recently passed.

physics.ins-det

Photon Reconstruction in the Belle II Calorimeter Using Graph Neural Networks

We present the study of a fuzzy clustering algorithm for the Belle II electromagnetic calorimeter using Graph Neural Networks. We use a realistic detector simulation including simulated beam backgrounds and focus on the reconstruction of both isolated and overlapping photons. We find significant improvements of the energy resolution compared to the currently used reconstruction algorithm for both isolated and overlapping photons of more than 30% for photons with energies E < 0.5 GeV and high levels of beam backgrounds. Overall, the GNN reconstruction improves the resolution and reduces the tails of the reconstructed energy distribution and therefore is a promising option for the upcoming high luminosity running of Belle II.

hep-ex

Energetic neutron identification with pulse shape discrimination in pure CsI crystals

Pulse shape discrimination with pure CsI scintillators is investigated as a method for separating energy deposits by energetic neutrons and photons at particle physics experiments. Using neutron data collected near the European XFEL XS1 beam window the pulse shape discrimination capabilities of pure CsI are studied and compared to CsI(Tl) using near-identical detector setups, which were operated in parallel. The inelastic interactions of 100MeV neutrons are observed to produce a slower scintillation emission in pure CsI relative to energy deposits from cosmic muons. By employing a charge-ratio method for pulse shape characterization, pulse shape discrimination with pure CsI is shown to be effective for identifying energy deposits from neutrons vs. cosmic muons, however, pure CsI was not able resolve the specific type of neutron inelastic interactions as can be done with CsI(Tl). Using pulse shape discrimination, the rate of energetic neutron interactions in a pure CsI detector is measured as a function of time and shown to be correlated with the European XFEL beam power. The results demonstrate that pulse shape discrimination with pure CsI has significant potential to improve electromagnetic vs. hadronic shower identification at future particle physics experiments.

physics.ins-det

$B$-flavor tagging at Belle II

We report on new flavor tagging algorithms developed to determine the quark-flavor content of bottom ($B$) mesons at Belle II. The algorithms provide essential inputs for measurements of quark-flavor mixing and charge-parity violation. We validate and evaluate the performance of the algorithms using hadronic $B$ decays with flavor-specific final states reconstructed in a data set corresponding to an integrated luminosity of $62.8$ fb$^{-1}$, collected at the $\Upsilon$(4$S$) resonance with the Belle II detector at the SuperKEKB collider. We measure the total effective tagging efficiency to be $\varepsilon_{\rm eff} = \big(30.0 \pm 1.2(\text{stat}) \pm 0.4(\text{syst})\big)\%$ for a category-based algorithm and $\varepsilon_{\rm eff} = \big(28.8 \pm 1.2(\text{stat}) \pm 0.4(\text{syst})\big)\%$ for a deep-learning-based algorithm.

hep-ex

CsI(Tl) Pulse Shape Discrimination with the Belle II Electromagnetic Calorimeter as a Novel Method to Improve Particle Identification at Electron-Positron Colliders

This paper describes the implementation and performance of CsI(Tl) pulse shape discrimination for the Belle II electromagnetic calorimeter, representing the first application of CsI(Tl) pulse shape discrimination for particle identification at an electron-positron collider. The pulse shape characterization algorithms applied by the Belle II calorimeter are described. Control samples of $\gamma$, $\mu^+$, $\pi^\pm$, $K^\pm$ and $p/\bar{p}$ are used to demonstrate the significant insight into the secondary particle composition of calorimeter clusters that is provided by CsI(Tl) pulse shape discrimination. Comparisons with simulation are presented and provide further validation for newly developed CsI(Tl) scintillation response simulation techniques, which when incorporated with GEANT4 simulations allow the particle dependent scintillation response of CsI(Tl) to be modelled. Comparisons between data and simulation also demonstrate that pulse shape discrimination can be a new tool to identify sources of improvement in the simulation of hadronic interactions in materials. The $K_L^0$ efficiency and photon-as-hadron fake-rate of a multivariate classifier that is trained to use pulse shape discrimination is presented and comparisons are made to a shower-shape based approach. CsI(Tl) pulse shape discrimination is shown to reduce the photon-as-hadron fake-rate by over a factor of 3 at photon energies of 0.2 GeV and over a factor 10 at photon energies of 1 GeV.

physics.ins-det

First Measurements of Beam Backgrounds at SuperKEKB

The high design luminosity of the SuperKEKB electron-positron collider is expected to result in challenging levels of beam-induced backgrounds in the interaction region. Properly simulating and mitigating these backgrounds is critical to the success of the Belle~II experiment. We report on measurements performed with a suite of dedicated beam background detectors, collectively known as BEAST II, during the so-called Phase 1 commissioning run of SuperKEKB in 2016, which involved operation of both the high energy ring (HER) of 7 GeV electrons as well as the low energy ring (LER) of 4 GeV positrons. We describe the BEAST II detector systems, the simulation of beam backgrounds, and the measurements performed. The measurements include standard ones of dose rates versus accelerator conditions, and more novel investigations, such as bunch-by-bunch measurements of injection backgrounds and measurements sensitive to the energy spectrum and angular distribution of fast neutrons. We observe beam-gas, Touschek, beam-dust, and injection backgrounds. We do not observe significant synchrotron radiation, as expected. Measured LER beam-gas backgrounds and Touschek backgrounds in both rings are slightly elevated, on average three times larger than the levels predicted by simulation. HER beam-gas backgrounds are on on average two orders of magnitude larger than predicted. Systematic uncertainties and channel-to-channel variations are large, so that these excesses constitute only 1-2 sigma level effects. Neutron background rates are higher than predicted and should be studied further. We will measure the remaining beam background processes, due to colliding beams, in the imminent commissioning Phase 2. These backgrounds are expected to be the most critical for Belle II, to the point of necessitating replacement of detector components during the Phase 3 (full-luminosity) operation of SuperKEB.

physics.ins-det

State-to-state vibrational kinetics of H$_2$ and H$_2^+$ in a post-shock cooling gas with primordial composition

The radiative cooling of shocked gas with primordial chemical composition is an important process relevant to the formation of the first stars and structures, as well as taking place also in high velocity cloud collisions and supernovae explosions. Among the different processes that need to be considered, the formation kinetics and cooling of molecular hydrogen are of prime interest, since they provide the only way to lower the gas temperature to values well below $\sim$10$^4$~K. In previous works, the internal energy level structure of H$_2$ and its cation has been treated in the approximation of rovibrational ground state at low densities, or trying to describe the dynamics using some arbitrary $v>0$ H$_2$ level that is considered representative of the excited vibrational manifold. In this study, we compute the vibrationally resolved kinetics for the time-dependent chemical and thermal evolution of the post-shock gas in a medium of primordial composition. The calculated non-equilibrium distributions are used to evaluate effects on the cooling function of the gas and on the cooling time. Finally, we discuss the dependence of the results to different initial values of the shock velocity and redshift.

astro-ph.GA

Monte Carlo calculation of the translational relaxation of superthermal H atoms in thermal H2 gas

We propose a simple and reliable method to study the translational relaxation of 'hot' H atoms following their production by chemical mechanisms. The problem is relevant to PDR's, shocks, photospheres, atmospheric entry problems. We show that the thermalization of H atoms can be conveniently studied by a simple method and set the basis for further investigations. The method adopted is Monte Carlo method including the thermal distribution of background molecules. The transport cross section is determined by the inversion of transport data. Plots of the collisions density of H atoms in H$_{2}$ gas are calculated and discussed also in the context of simple theories. The application of the results to astrophysical problems is outlined including numerical results for the reaction H + H$_{2}$O $\rightarrow$ H$_{2}$ + OH.

physics.plasm-ph

IGEC2: A 17-month search for gravitational wave bursts in 2005-2007

We present here the results of a 515 days long run of the IGEC2 observatory, consisting of the four resonant mass detectors ALLEGRO, AURIGA, EXPLORER and NAUTILUS. The reported results are related to the fourfold observation time from Nov. 6 2005 until Apr. 14 2007, when Allegro ceased its operation. This period overlapped with the first long term observations performed by the LIGO interferometric detectors. The IGEC observations aim at the identification of gravitational wave candidates with high confidence, keeping the false alarm rate at the level of 1 per century, and high duty cycle, namely 57% with all four sites and 94% with at least three sites in simultaneous observation. The network data analysis is based on time coincidence searches over at least three detectors: the four 3-fold searches and the 4-fold one are combined in a logical OR. We exchanged data with the usual blind procedure, by applying a unique confidential time offset to the events in each set of data. The accidental background was investigated by performing sets of 10^8 coincidence analyses per each detector configuration on off-source data, obtained by shifting the time series of each detector. The thresholds of the five searches were tuned so as to control the overall false alarm rate to 1/century. When the confidential time shifts was disclosed, no gravitational wave candidate was found in the on-source data. As an additional output of this search, we make available to other observatories the list of triple coincidence found below search thresholds, corresponding to a false alarm rate of 1/month.

gr-qc

Quantum Zeno effect in a multilevel molecule

We study the dynamics of the populations of a model molecule endowed with two sets of rotational levels of different parity, whose ground levels are energy degenerate and coupled by a constant interaction. The relaxation rate from one set of levels to the other one has an interesting dependence on the average collision frequency of the molecules in the gas. This is interpreted as a quantum Zeno effect due to the decoherence effects provoked by the molecular collisions.

quant-ph

Nonequilibrium steady state fluctuations in actively cooled resonators

We analyze heat and work fluctuations in the gravitational wave detector AURIGA, modeled as a macroscopic electromechanical oscillator in contact with a thermostat and cooled by an active feedback system. The oscillator is driven to a steady state by the feedback cooling, equivalent to a viscous force. The experimentally measured fluctuations are in agreement with our theoretical analysis based on a stochastically driven Langevin system. The asymmetry of the fluctuations of the absorbed heat characterizes the oscillator's nonequilibrium steady state and reveals the extent to which a feedback cooled system departs from equilibrium in a statistical mechanics perspective.

cond-mat.stat-mech

Feedback cooling of the normal modes of a massive electromechanical system to submillikelvin temperature

We apply a feedback cooling technique to simultaneously cool the three electromechanical normal modes of the ton-scale resonant-bar gravitational wave detector AURIGA. The measuring system is based on a dc Superconducting Quantum Interference Device (SQUID) amplifier, and the feedback cooling is applied electronically to the input circuit of the SQUID. Starting from a bath temperature of 4.2 K, we achieve a minimum temperature of 0.17 mK for the coolest normal mode. The same technique, implemented in a dedicated experiment at subkelvin bath temperature and with a quantum limited SQUID, could allow to approach the quantum ground state of a kilogram-scale mechanical resonator.

quant-ph

Non equilibrium velocity distributions of H- ions in H2 plasmas and photodetachment measurements

A theoretical study of the energy distribution function of the negative hydrogen ion H- in typical conditions for multicusp ion sources is presented. The case of H/H2 mixture is studied by a Monte Carlo solution of the kinetic equation for H- transport. A simple analytical model is obtained for the case of a fully dissociated H plasma and uniform reduced electric field (E/N). Results are in good agreement with the two-group distribution deduced from laser photodetachment experiments and explain the low energy group as an effect of the charge exchange collisions of negative ions with H atoms.

physics.plasm-ph