SearcharxivSearch

arXiv subjects

S. M. Lee

Publications and source records attributed to S. M. Lee.

At least 19 recordsLinked to original sources

KATRIN Sensitivity to keV Sterile Neutrinos with the TRISTAN Detector Upgrade

Sterile neutrinos in the keV mass range are a well-motivated extension of the Standard Model and viable dark matter candidates. Their existence can be probed in laboratory experiments, as the admixture of a sterile state would induce a characteristic kink-like distortion in the $β$-decay electron energy spectrum. The KATRIN experiment is designed to measure the effective electron neutrino mass with sub-eV sensitivity by analyzing the endpoint region of the tritium $β$-decay spectrum. Following the completion of its neutrino mass program, KATRIN will extend its physics reach to the search for keV-scale sterile neutrinos. This effort will be enabled by the TRISTAN detector, a newly developed silicon drift detector array optimized for differential measurements at high rates and energies well below the endpoint. In this article, we present the projected sensitivity of KATRIN to keV-scale sterile neutrinos using a dedicated simulation framework. With four months of detector livetime, KATRIN has the statistical power to probe mixing amplitudes at the level of $|U_{e4}|^2 \sim 10^{-6}$ for sterile neutrino masses in the (4$-$13) keV range, significantly extending the reach of previous laboratory searches. The major experimental systematic uncertainties investigated in this work reduces the sensitivity by a factor of 10$-$50 over the same mass range.

hep-ex

Constraints on sub-GeV dark matter scattering on electrons with COSINE-100

We present results of the search for sub-GeV dark matter interaction with electrons in the NaI(Tl) crystals of the COSINE-100 experiment. The two benchmark scenarios of a heavy and a light vector boson as mediator of the interaction were studied. We found no excess events over the expected background in a data-set of 2.82 years, with a total exposure of 172.9 kg-year. The derived 90% confidence level upper limits exclude a DM-electron scattering cross section above 6.4 $\times$ 10$^{-33}$ cm$^2$ for a DM mass of 0.25 GeV, assuming a light mediator; and above 3.4 $\times$ 10$^{-37}$ cm$^2$ for a 0.4 GeV DM, assuming a heavy mediator, and represent the most stringent constraints for a NaI(Tl) target to date. We also briefly discuss a planned analysis using an annual modulation method below the current 0.7 keV threshold of COSINE-100, down to few photoelectrons yield.

hep-ex

Measurement of coherent elastic neutrino nucleus scattering on germanium by COHERENT

The COHERENT collaboration reports the most precise measurement of the coherent elastic neutrino-nucleus scattering cross section to date. This measurement was performed with COHERENT's germanium detector array, Ge-Mini, at the Spallation Neutron Source at Oak Ridge National Laboratory. A cumulative exposure of $4.68\times10^{22}$ protons on target yielded a total number of observed counts of $124^{+14}_{-12}$ and a flux-averaged cross section of $1.00 \pm 0.10 \mathrm{(statistical)} \pm 0.10 \mathrm{(systematic)}$ relative to the standard-model expectation of $5.9\times10^{-39} \mathrm{cm}^2$. The well-understood energy and timing distributions of the neutrino source allow for independent measurements of muon- and electron-neutrino scattering rates. This information is used to improve constraints on non-standard neutrino interactions mediated by heavy particles.

hep-ex

The COHERENT Experiment: 2026 Update

The COHERENT experiment measures neutrino-induced recoils from coherent elastic neutrino-nucleus scattering (CEvNS) with multiple nuclear targets at the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL), USA. Several successful CEvNS measurements have been achieved in recent years with tens-of-kg detector masses, with a CsI scintillating crystal, a liquid argon single-phase detector, and high-purity germanium spectrometers. For the next phase, COHERENT aims at high-statistics detection of CEvNS events for precision tests of the standard model of particle physics, and to probe new physics beyond-the-standard model. Percent-level precision can be achieved by lowering thresholds, reducing backgrounds, and by scaling up the detector masses. It goes hand in hand with benchmarking the neutrino flux from the SNS. Further detectors will measure CEvNS in additional nuclei, including lighter target nuclei such as sodium and neon, to continue to test the expected neutron-number-squared dependence of the cross section. COHERENT can furthermore study charged-current and neutral-current inelastic neutrino-nucleus cross sections on various nuclei at neutrino energies below $\sim$50 MeV. Many of these cross sections have never been measured before, but are critical input for the interpretation of core-collapse supernova detection in large-scale neutrino experiments such as DUNE, Super-K, Hyper-K, and HALO.

hep-ex

Limits on WIMP dark matter with NaI(Tl) crystals in three years of COSINE-100 data

We report limits on WIMP dark matter derived from three years of data collected by the COSINE-100 experiment with NaI(Tl) crystals, achieving an improved energy threshold of 0.7 keV. This lowered threshold enhances sensitivity in the sub-GeV mass range, extending the reach for direct detection of low-mass dark matter. Although no excess of WIMP-like events was observed, the increased sensitivity enabled a model-insensitive comparison between the expected WIMP signal rate-based on mass limits from our data-and DAMA's reported modulation amplitude. Our findings strongly disfavor the DAMA signal as originating from WIMP interactions, fully excluding DAMA/LIBRA 3$σ$ allowed regions and providing enhanced WIMP mass limits by an order of magnitude in the spin-independent model compared to previous results. In the spin-dependent model, cross-section upper limits were obtained in the mass range [0.1-5.0] GeV/c$^2$, with additional sensitivity to sub-GeV WIMPs through the inclusion of the Migdal effect. These results represent substantial progress in low-mass dark matter exploration and reinforce constraints on the longstanding DAMA claim.

hep-ex

Combined Annual Modulation Dark Matter Search with COSINE-100 and ANAIS-112

The annual modulation signal, claimed to be consistent with dark matter as observed by DAMA/LIBRA in a sodium-iodide based detector, has persisted for over two decades. COSINE-100 and ANAIS-112 were designed to test the claim directly using the same target material. COSINE-100, located at Yangyang Underground Laboratory in South Korea, and ANAIS-112, located at Canfranc Underground Laboratory in Spain, have been taking data since 2016 and 2017, respectively. Each experiment published its respective results independently. In this paper, we present the results of an annual modulation search as a test of the signal observed by DAMA/LIBRA with the first three respective years of data from COSINE-100 and ANAIS-112. Using a Markov Chain Monte Carlo method, we find best fit values for modulation amplitude of $-0.0002 {\pm} 0.0026$ cpd/kg/keV in the 1-6 keV and $0.0021 {\pm} 0.0028$ cpd/kg/keV in the 2-6 keV energy regions. These results are not compatible with DAMA/LIBRA's assertion for their observation of annual modulation at $3.7σ$ and $2.6σ$, respectively. Performing a simple combination of the newly released 6-years datasets from both experiments find values consistent with no modulation at $0.0005 {\pm} 0.0019$ cpd/kg/keV in the 1-6 keV and $0.0027 {\pm} 0.0021$ cpd/kg/keV in the 2-6 keV energy regions with $4.68σ$ and $3.53σ$ respective exclusions of the DAMA/LIBRA signal.

astro-ph.IM

COSINE-100 Full Dataset Challenges the Annual Modulation Signal of DAMA/LIBRA

For over 25 years, the DAMA/LIBRA collaboration has claimed to observe an annual modulation signal, suggesting the existence of dark matter interactions. However, no experiment employing different target materials has observed a dark matter signal consistent with their result. To address this puzzle, the COSINE-100 collaboration conducted a model-independent test using sodium iodide crystal detectors, the same target material as DAMA/LIBRA. Analyzing data collected over 6.4 years by the effective mass of 61.3 kg, with improved energy calibration and time-dependent background modeling, we found no evidence of an annual modulation signal, challenging the DAMA/LIBRA result with a confidence level greater than 3$σ$. This finding represents a substantial step toward resolving the long-standing debate surrounding DAMA/LIBRA's dark matter claim, indicating that the observed modulation is unlikely to be caused by dark matter interactions.

hep-ex

Radiopurity measurements of liquid scintillator for the COSINE-100 Upgrade

A new 2,400 L liquid scintillator has been produced for the COSINE-100 Upgrade, which is under construction at Yemilab for the next COSINE dark matter experiment phase. The linear-alkyl-benzene-based scintillator is designed to serve as a veto for NaI(Tl) crystal targets and a separate platform for rare event searches. We measured using a sample consisting of a custom-made 445 mL cylindrical Teflon container equipped with two 3-inch photomultiplier tubes. Analyses show activity levels of $0.091 \pm 0.042$ mBq/kg for $^{238}$U and $0.012 \pm 0.007$ mBq/kg for $^{232}$Th.

physics.ins-det

Upgrading the COSINE-100 Experiment for Enhanced Sensitivity to Low-Mass Dark Matter Detection

The DAMA/LIBRA experiment has reported an annual modulation signal in NaI(Tl) detectors, which has been interpreted as a possible indication of dark matter interactions. However, this claim remains controversial, as several experiments have tested the modulation signal using NaI(Tl) detectors. Among them, the COSINE-100 experiment, specifically designed to test DAMA/LIBRA's claim, observed no significant signal, revealing a more than 3 $σ$ discrepancy with DAMA/LIBRA's results. Here we present COSINE-100U, an upgraded version of the experiment, which aims to expand the search for dark matter interactions by improving light collection efficiency and reducing background noise. The detector, consisting of eight NaI(Tl) crystals with a total mass of 99.1 kg, has been relocated to Yemilab, a new underground facility in Korea, and features direct PMT-coupling technology to enhance sensitivity. These upgrades significantly improve the experiment's ability to probe low-mass dark matter candidates, contributing to the ongoing global effort to clarify the nature of dark matter.

hep-ex

Lowering threshold of NaI(Tl) scintillator to 0.7 keV in the COSINE-100 experiment

COSINE-100 is a direct dark matter search experiment, with the primary goal of testing the annual modulation signal observed by DAMA/LIBRA, using the same target material, NaI(Tl). In previous analyses, we achieved the same 1 keV energy threshold used in the DAMA/LIBRA's analysis that reported an annual modulation signal with 11.6$σ$ significance. In this article, we report an improved analysis that lowered the threshold to 0.7 keV, thanks to the application of Multi-Layer Perception network and a new likelihood parameter with waveforms in the frequency domain. The lower threshold would enable a better comparison of COSINE-100 with new DAMA results with a 0.75 keV threshold and account for differences in quenching factors. Furthermore the lower threshold can enhance COSINE-100's sensitivity to sub-GeV dark matter searches.

hep-ex

Improved background modeling for dark matter search with COSINE-100

COSINE-100 aims to conclusively test the claimed dark matter annual modulation signal detected by DAMA/LIBRA collaboration. DAMA/LIBRA has released updated analysis results by lowering the energy threshold to 0.75 keV through various upgrades. They have consistently claimed to have observed the annual modulation. In COSINE-100, it is crucial to lower the energy threshold for a direct comparison with DAMA/LIBRA, which also enhances the sensitivity of the search for low-mass dark matter, enabling COSINE-100 to explore this area. Therefore, it is essential to have a precise and quantitative understanding of the background spectrum across all energy ranges. This study expands the background modeling from 0.7 to 4000 keV using 2.82 years of COSINE-100 data. The modeling has been improved to describe the background spectrum across all energy ranges accurately. Assessments of the background spectrum are presented, considering the nonproportionality of NaI(Tl) crystals at both low and high energies and the characteristic X-rays produced by the interaction of external backgrounds with materials such as copper. Additionally, constraints on the fit parameters obtained from the alpha spectrum modeling fit are integrated into this model. These improvements are detailed in the paper.

astro-ph.IM

Waveform Simulation for Scintillation Characteristics of NaI(Tl) Crystal

The lowering of the energy threshold in the NaI detector is crucial not only for comprehensive validation of DAMA/LIBRA but also for exploring new possibilities in the search for low-mass dark matter and observing coherent elastic scattering between neutrino and nucleus. Alongside hardware enhancements, extensive efforts have focused on refining event selection to discern noise, achieved through parameter development and the application of machine learning. Acquiring pure, unbiased datasets is crucial in this endeavor, for which a waveform simulation was developed. The simulation data were compared with the experimental data using several pulse shape discrimination parameters to test its performance in describing the experimental data. Additionally, we present the outcomes of multi-variable machine learning trained with simulation data as a scintillation signal sample. The distributions of outcomes for experimental and simulation data show a good agreement. As an application of the waveform simulation, we validate the trigger efficiency alongside estimations derived from the minimally biased measurement data.

physics.ins-det

Nonproportionality of NaI(Tl) Scintillation Detector for Dark Matter Search Experiments

We present a comprehensive study of the nonproportionality of NaI(Tl) scintillation detectors within the context of dark matter search experiments. Our investigation, which integrates COSINE-100 data with supplementary $γ$ spectroscopy, measures light yields across diverse energy levels from full-energy $γ$ peaks produced by the decays of various isotopes. These $γ$ peaks of interest were produced by decays supported by both long and short-lived isotopes. Analyzing peaks from decays supported only by short-lived isotopes presented a unique challenge due to their limited statistics and overlapping energies, which was overcome by long-term data collection and a time-dependent analysis. A key achievement is the direct measurement of the 0.87 keV light yield, resulting from the cascade following electron capture decay of $^{22}$Na from internal contamination. This measurement, previously accessible only indirectly, deepens our understanding of NaI(Tl) scintillator behavior in the region of interest for dark matter searches. This study holds substantial implications for background modeling and the interpretation of dark matter signals in NaI(Tl) experiments.

hep-ex

Alpha backgrounds in NaI(Tl) crystals of COSINE-100

COSINE-100 is a dark matter direct detection experiment with 106 kg NaI(Tl) as the target material. 210Pb and daughter isotopes are a dominant background in the WIMP region of interest and are detected via beta decay and alpha decay. Analysis of the alpha channel complements the background model as observed in the beta/gamma channel. We present the measurement of the quenching factors and Monte Carlo simulation results and activity quantification of the alpha decay components of the COSINE-100 NaI(Tl) crystals. The data strongly indicate that the alpha decays probabilistically undergo two possible quenching factors but require further investigation. The fitted results are consistent with independent measurements and improve the overall understanding of the COSINE-100 backgrounds. Furthermore, the half-life of 216Po has been measured to be 143.4 +/- 1.2 ms, which is consistent with and more precise than recent measurements.

astro-ph.IM

Search for inelastic WIMP-iodine scattering with COSINE-100

We report the results of a search for inelastic scattering of weakly interacting massive particles (WIMPs) off $^{127}$I nuclei using NaI(Tl) crystals with a data exposure of 97.7 kg$\cdot$years from the COSINE-100 experiment. The signature of inelastic WIMP-$^{127}$I scattering is a nuclear recoil accompanied by a 57.6 keV $γ$-ray from the prompt deexcitation, producing a more energetic signal compared to the typical WIMP nuclear recoil signal. We found no evidence for this inelastic scattering signature and set a 90 $\%$ confidence level upper limit on the WIMP-proton spin-dependent, inelastic scattering cross section of $1.2 \times 10^{-37} {\rm cm^{2}}$ at the WIMP mass 500 ${\rm GeV/c^{2}}$.

hep-ex

Search for Boosted Dark Matter in COSINE-100

We search for energetic electron recoil signals induced by boosted dark matter (BDM) from the galactic center using the COSINE-100 array of NaI(Tl) crystal detectors at the Yangyang Underground Laboratory. The signal would be an excess of events with energies above 4 MeV over the well-understood background. Because no excess of events are observed in a 97.7 kg$\cdot$years exposure, we set limits on BDM interactions under a variety of hypotheses. Notably, we explored the dark photon parameter space, leading to competitive limits compared to direct dark photon search experiments, particularly for dark photon masses below 4\,MeV and considering the invisible decay mode. Furthermore, by comparing our results with a previous BDM search conducted by the Super-Kamionkande experiment, we found that the COSINE-100 detector has advantages in searching for low-mass dark matter. This analysis demonstrates the potential of the COSINE-100 detector to search for MeV electron recoil signals produced by the dark sector particle interactions.

hep-ex

Search for bosonic super-weakly interacting massive particles at COSINE-100

We present results of a search for bosonic super-weakly interacting massive particles (BSW) as keV scale dark matter candidates that is based on an exposure of 97.7 kg$\cdot$year from the COSINE experiment. In this search, we employ, for the first time, Compton-like as well as absorption processes for pseudoscalar and vector BSWs. No evidence for BSWs is found in the mass range from 10 $\mathrm{keV/c}^2$ to 1 $\mathrm{MeV/c}^2$, and we present the exclusion limits on the dimensionless coupling constants to electrons $g_{ae}$ for pseudoscalar and $κ$ for vector BSWs at 90% confidence level. Our results show that these limits are improved by including the Compton-like process in masses of BSW, above $\mathcal{O}(100\,\mathrm{keV/c}^2)$.

hep-ex

Search for solar bosonic dark matter annual modulation with COSINE-100

We present results from a search for solar bosonic dark matter using the annual modulation method with the COSINE-100 experiment. The results were interpreted considering three dark sector bosons models: solar dark photon; DFSZ and KSVZ solar axion; and Kaluza-Klein solar axion. No modulation signal that is compatible with the expected from the models was found from a data-set of 2.82 yr, using 61.3 kg of NaI(Tl) crystals. Therefore, we set a 90$\%$ confidence level upper limits for each of the three models studied. For the solar dark photon model, the most stringent mixing parameter upper limit is $1.61 \times 10^{-14}$ for dark photons with a mass of 215 eV. For the DFSZ and KSVZ solar axion, and the Kaluza-Klein axion models, the upper limits exclude axion-electron couplings, $g_{ae}$, above $1.61 \times 10^{-11}$ for axion mass below 0.2 keV; and axion-photon couplings, $g_{aγγ}$, above $1.83 \times 10^{-11}$ GeV$^{-1}$ for an axion number density of $4.07 \times 10^{13}$ cm$^{-3}$. This is the first experimental search for solar dark photons and DFSZ and KSVZ solar axions using the annual modulation method. The lower background, higher light yield and reduced threshold of NaI(Tl) crystals of the future COSINE-200 experiment are expected to enhance the sensitivity of the analysis shown in this paper. We show the sensitivities for the three models studied, considering the same search method with COSINE-200.

hep-ex