Searcharxiv⌕ Search

arXiv subjects

S. M. Mazza

Publications and source records attributed to S. M. Mazza.

21 records · Page 2Linked to original sources

Layout and Performance of HPK Prototype LGAD Sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising edge, which improve significantly the signal-to-noise ratio. The required average timing resolution per track for a minimum-ionising particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1 MeV-neutron equivalent fluence up to $2.5 \times 10^{15} cm^{-2}$ before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-up at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

physics.ins-det↗

Proprieties of FBK UFSDs after neutron and proton irradiation up to 6*10e15 neq/cm2

The properties of 60-μm thick Ultra-Fast Silicon Detectors (UFSD) detectors manufactured by Fondazione Bruno Kessler (FBK), Trento (Italy) were tested before and after irradiation with minimum ionizing particles (MIPs) from a 90Sr \b{eta}-source . This FBK production, called UFSD2, has UFSDs with gain layer made of Boron, Boron low-diffusion, Gallium, Carbonated Boron and Carbonated. The irradiation with neutrons took place at the TRIGA reactor in Ljubljana, while the proton irradiation took place at CERN SPS. The sensors were exposed to a neutron fluence of 4*10e14, 8*1014, 1.5*10e15, 3*10e15, 6*10e15 neq/cm2 and to a proton fluence of 9.6*10e14 p/cm2, equivalent to a fluence of 6*10e14 neq/cm2. The internal gain and the timing resolution were measured as a function of bias voltage at -20C. The timing resolution was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction method for both.

physics.ins-det↗

Comparison of 35 and 50 μm thin HPK UFSD after neutron irradiation up to 6*10^15 neq/cm^2

We report results from the testing of 35 μm thick Ultra-Fast Silicon Detectors (UFSD produced by Hamamatsu Photonics (HPK), Japan and the comparison of these new results to data reported before on 50 μm thick UFSD produced by HPK. The 35 μm thick sensors were irradiated with neutrons to fluences of 0, 1*10^14, 1*10^15, 3*10^15, 6*10^15 neq/cm^2. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particles (MIPs) from a 90Sr \b{eta}-source. The leakage current, capacitance, internal gain and the timing resolution were measured as a function of bias voltage at -20C and -27C. The timing resolution was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction method for both. Within the fluence range measured, the advantage of the 35 μm thick UFSD in timing accuracy, bias voltage and power can be established.

physics.ins-det↗