SearcharxivSearch

arXiv subjects

S. Mazzoni

Publications and source records attributed to S. Mazzoni.

At least 19 recordsLinked to original sources

An electro-optical bunch profile monitor for FCC-ee

The Future Circular Lepton Collider (FCC-ee) presents challenges for a longitudinal bunch profile monitor due to its wide range of bunch lengths and charge densities across its four distinct operational modes. For commissioning, monitoring the top-up injection, and energy calibration, the FCC-ee requires non-destructive, single-shot measurements of the bunch length and profile. This contribution proposes an in-vacuum electro-optical (EO) longitudinal bunch profile monitor for single-shot measurements at high repetition rates, building on the successful EO monitor at the Karlsruhe Research Accelerator (KARA) at the Karlsruhe Institute of Technology. A novel single-pass conceptual design for the in-vacuum holder of the electro-optical crystal is presented, utilizing prisms instead of a mirror to guide the laser through the crystal, which additionally allows measurements of the long bunches foreseen for FCC-ee operation mode at the Z-pole energy. A first prototype has been constructed and tested at the in-air test stand of the CERN Linear Electron Accelerator for Research (CLEAR). Results from the prototype tests are presented, demonstrating the proof of principle for the single-pass prism-based EO monitor design for FCC-ee.

physics.acc-ph

Measurement of the emittance of accelerated electron bunches at the AWAKE experiment

The vertical plane transverse emittance of accelerated electron bunches at the AWAKE experiment at CERN has been determined, using three different methods of data analysis. This is a proof-of-principle measurement using the existing AWAKE electron spectrometer to validate the measurement technique. Large values of the geometric emittance, compared to that of the injection beam, are observed ($\sim \SI{0.5}{\milli\metre\milli\radian}$ compared with $\sim \SI{0.08}{\milli\metre\milli\radian}$), which is in line with expectations of emittance growth arising from plasma density ramps and large injection beam bunch size. Future iterations of AWAKE are anticipated to operate in conditions where emittance growth is better controlled, and the effects of the imaging systems of the existing and future spectrometer designs on the ability to measure the emittance are discussed. Good performance of the instrument down to geometric emittances of approximately $\SI{1e-4}{\milli\metre\milli\radian}$ is required, which may be possible with improved electron optics and imaging.

physics.acc-ph

Optical Transmission Characterization of Fused Silica Materials Irradiated at the CERN Large Hadron Collider

The Target Absorbers for Neutrals (TANs) represent one of the most radioactive regions in the Large Hadron Collider (LHC). Seven 40 cm long fused silica rods with different dopant specifications, manufactured by Heraeus, were irradiated in one of the TANs located around the ATLAS experiment by the Beam RAte of Neutrals (BRAN) detector group. This campaign took place during the Run 2 p+p data taking, which occurred between 2016 and 2018. This paper reports a complete characterization of optical transmission per unit length of irradiated fused silica materials as a function of wavelength (240 nm - 1500 nm), dose (up to 18 MGy), and level of OH and H$_2$ dopants introduced in the manufacturing process. The dose delivered to the rods was estimated using Monte Carlo simulations performed by the CERN FLUKA team.

physics.ins-det

Mapping charge capture and acceleration in a plasma wakefield of a proton bunch using variable emittance electron beam injection

In the Phase 2 of the AWAKE first experimental run (from May to November 2018), an electron beam was used to probe and test proton-driven wakefield acceleration in a rubidium plasma column. In this work, we analyze the overall charge capture and shot-to-shot reproducibility of the proton-driven plasma wakefield accelerator with various electron bunch injection parameters. The witness electron bunches were produced using an RF-gun equipped with a Cs2Te photocathode illuminated by a tailorable ultrafast deep ultraviolet (UV) laser pulse. The construction of the UV beam optical system enabled appropriate transverse beam shaping and control of its pulse duration, size, and position on the photocathode, as well as time delay with respect to the ionizing laser pulse that seeds the plasma wakefields in the proton bunches. Variable photocathode illumination provided the required flexibility to produce electron bunches with variable charge, emittance, and injection trajectory into the plasma column. We demonstrate charge capture rates exceeding 15% (40 pC of GeV accelerated charge for a 385 pC injected electron bunch) under optimized electron injection conditions.

physics.acc-ph

$^{22}$Na Activation Level Measurements of Fused Silica Rods in the LHC Target Absorber for Neutrals (TAN) Compared to FLUKA Simulations

The Target Absorbers for Neutrals (TANs) are located in a high-intensity radiation environment inside the tunnel of the Large Hadron Collider (LHC). TANs are positioned about $140$ m downstream from the beam interaction points. Seven $40$ cm long fused silica rods with different dopant specifications were irradiated in the TAN by the Beam RAte of Neutrals (BRAN) detector group during $p$+$p$ data taking from 2016 to 2018 at the LHC. The peak dose delivered to the fused silica rods was $18$ MGy. We report measurements of the $^{22}$Na activation of the fused silica rods carried out at the University of Illinois at Urbana-Champaign and Argonne National Laboratory. At the end of the irradiation campaign, the maximum $^{22}$Na activity observed was $A=21$ kBq$/{\rm cm^3}$ corresponding to a density, $\rho= 2.5\times 10^{12} /{\rm cm^3}$, of $^{22}$Na nuclei. FLUKA Monte Carlo simulations have been performed by the CERN FLUKA team to estimate $^{22}$Na activities for the irradiated BRAN rod samples. The simulations reproduce the $^{22}$Na activity profile measured along the rods, with a 35% underestimation of the experimental measurement results.

physics.acc-ph

Analysis of Proton Bunch Parameters in the AWAKE Experiment

A precise characterization of the incoming proton bunch parameters is required to accurately simulate the self-modulation process in the Advanced Wakefield Experiment (AWAKE). This paper presents an analysis of the parameters of the incoming proton bunches used in the later stages of the AWAKE Run 1 data-taking period. The transverse structure of the bunch is observed at multiple positions along the beamline using scintillating or optical transition radiation screens. The parameters of a model that describes the bunch transverse dimensions and divergence are fitted to represent the observed data using Bayesian inference. The analysis is tested on simulated data and then applied to the experimental data.

physics.acc-ph

Simulation and Experimental Study of Proton Bunch Self-Modulation in Plasma with Linear Density Gradients

We present numerical simulations and experimental results of the self-modulation of a long proton bunch in a plasma with linear density gradients along the beam path. Simulation results agree with the experimental results reported in arXiv:2007.14894v2: with negative gradients, the charge of the modulated bunch is lower than with positive gradients. In addition, the bunch modulation frequency varies with gradient. Simulation results show that dephasing of the wakefields with respect to the relativistic protons along the plasma is the main cause for the loss of charge. The study of the modulation frequency reveals details about the evolution of the self-modulation process along the plasma. In particular for negative gradients, the modulation frequency across time-resolved images of the bunch indicates the position along the plasma where protons leave the wakefields. Simulations and experimental results are in excellent agreement.

physics.plasm-ph

Transition between Instability and Seeded Self-Modulation of a Relativistic Particle Bunch in Plasma

We use a relativistic ionization front to provide various initial transverse wakefield amplitudes for the self-modulation of a long proton bunch in plasma. We show experimentally that, with sufficient initial amplitude ($\ge(4.1\pm0.4)$ MV/m), the phase of the modulation along the bunch is reproducible from event to event, with 3 to 7% (of 2$\pi$) rms variations all along the bunch. The phase is not reproducible for lower initial amplitudes. We observe the transition between these two regimes. Phase reproducibility is essential for deterministic external injection of particles to be accelerated.

physics.plasm-ph

Experimental study of extended timescale dynamics of a plasma wakefield driven by a self-modulated proton bunch

Plasma wakefield dynamics over timescales up to 800 ps, approximately 100 plasma periods, are studied experimentally at the Advanced Wakefield Experiment (AWAKE). The development of the longitudinal wakefield amplitude driven by a self-modulated proton bunch is measured using the external injection of witness electrons that sample the fields. In simulation, resonant excitation of the wakefield causes plasma electron trajectory crossing, resulting in the development of a potential outside the plasma boundary as electrons are transversely ejected. Trends consistent with the presence of this potential are experimentally measured and their dependence on wakefield amplitude are studied via seed laser timing scans and electron injection delay scans.

physics.plasm-ph

Proton beam defocusing in AWAKE: comparison of simulations and measurements

In 2017, AWAKE demonstrated the seeded self-modulation (SSM) of a 400 GeV proton beam from the Super Proton Synchrotron (SPS) at CERN. The angular distribution of the protons deflected due to SSM is a quantitative measure of the process, which agrees with simulations by the two-dimensional (axisymmetric) particle-in-cell code LCODE. Agreement is achieved for beam populations between $10^{11}$ and $3 \times 10^{11}$ particles, various plasma density gradients ($-20 \div 20\%$) and two plasma densities ($2\times 10^{14} \text{cm}^{-3}$ and $7 \times 10^{14} \text{cm}^{-3}$). The agreement is reached only in the case of a wide enough simulation box (at least five plasma wavelengths).

physics.acc-ph

Measurement and application of electron stripping of ultrarelativistic $^{208}\textrm{Pb}^{81+}$

New measurements of the stripping cross-section for ultrarelativistic hydrogen-like lead ions passing through aluminium and silicon have been performed at the Advanced Wakefield experiment at CERN. Agreement with existing measurements and theory has been obtained. Improvements in terms of electron beam quality and ion beam diagnostic capability, as well as further applications of such an electron beam, are discussed.

physics.acc-ph

Experimental observation of proton bunch modulation in a plasma, at varying plasma densities

We give direct experimental evidence for the observation of the full transverse self-modulation of a relativistic proton bunch propagating through a dense plasma. The bunch exits the plasma with a density modulation resulting from radial wakefield effects with a period reciprocal to the plasma frequency. We show that the modulation is seeded by using an intense laser pulse co-propagating with the proton bunch which creates a relativistic ionization front within the bunch. We show by varying the plasma density over one order of magnitude that the modulation period scales with the expected dependence on the plasma density.

physics.acc-ph

A magnetic spectrometer to measure electron bunches accelerated at AWAKE

A magnetic spectrometer has been developed for the AWAKE experiment at CERN in order to measure the energy distribution of bunches of electrons accelerated in wakefields generated by proton bunches in plasma. AWAKE is a proof-of-principle experiment for proton-driven plasma wakefield acceleration, using proton bunches from the SPS. Electron bunches are accelerated to $\mathcal{O}$(1 GeV) in a rubidium plasma cell and then separated from the proton bunches via a dipole magnet. The dipole magnet also induces an energy-dependent spatial horizontal spread on the electron bunch which then impacts on a scintillator screen. The scintillation photons emitted are transported via three highly-reflective mirrors to an intensified CCD camera, housed in a dark room, which passes the images to the CERN controls system for storage and further analysis. Given the known magnetic field and determination of the efficiencies of the system, the spatial spread of the scintillation photons can be converted to an electron energy distribution. A lamp attached on a rail in front of the scintillator is used to calibrate the optical system, with calibration of the scintillator screen's response to electrons carried out at the CLEAR facility at CERN. In this article, the design of the AWAKE spectrometer is presented, along with the calibrations carried out and expected performance such that the energy distribution of accelerated electrons can be measured.

physics.ins-det

Acceleration of electrons in the plasma wakefield of a proton bunch

High energy particle accelerators have been crucial in providing a deeper understanding of fundamental particles and the forces that govern their interactions. In order to increase the energy or reduce the size of the accelerator, new acceleration schemes need to be developed. Plasma wakefield acceleration, in which the electrons in a plasma are excited, leading to strong electric fields, is one such promising novel acceleration technique. Pioneering experiments have shown that an intense laser pulse or electron bunch traversing a plasma, drives electric fields of 10s GV/m and above. These values are well beyond those achieved in conventional RF accelerators which are limited to ~0.1 GV/m. A limitation of laser pulses and electron bunches is their low stored energy, which motivates the use of multiple stages to reach very high energies. The use of proton bunches is compelling, as they have the potential to drive wakefields and accelerate electrons to high energy in a single accelerating stage. The long proton bunches currently available can be used, as they undergo self-modulation, a particle-plasma interaction which longitudinally splits the bunch into a series of high density microbunches, which then act resonantly to create large wakefields. The AWAKE experiment at CERN uses intense bunches of protons, each of energy 400 GeV, with a total bunch energy of 19 kJ, to drive a wakefield in a 10 m long plasma. Bunches of electrons are injected into the wakefield formed by the proton microbunches. This paper presents measurements of electrons accelerated up to 2 GeV at AWAKE. This constitutes the first demonstration of proton-driven plasma wakefield acceleration. The potential for this scheme to produce very high energy electron bunches in a single accelerating stage means that the results shown here are a significant step towards the development of future high energy particle accelerators.

physics.acc-ph

Upgrade of the Two-Screen Measurement Setup in the AWAKE Experiment

The AWAKE project at CERN uses a self-modulated \SI{400}{GeV/c} proton bunch to drive GV/m wakefields in a \SI{10}{m} long plasma with an electron density of $n_{pe} = 7 \times 10^{14}\,\rm{electrons/cm}^3$. We present the upgrade of a proton beam diagnostic to indirectly prove that the bunch self-modulated by imaging defocused protons with two screens downstream the end of the plasma. The two-screen diagnostic has been installed, commissioned and tested in autumn 2016 and limitations were identified. We plan to install an upgraded diagnostics to overcome these limitations.

physics.acc-ph

AWAKE readiness for the study of the seeded self-modulation of a 400\,GeV proton bunch

AWAKE is a proton-driven plasma wakefield acceleration experiment. % We show that the experimental setup briefly described here is ready for systematic study of the seeded self-modulation of the 400\,GeV proton bunch in the 10\,m-long rubidium plasma with density adjustable from 1 to 10$\times10^{14}$\,cm$^{-3}$. % We show that the short laser pulse used for ionization of the rubidium vapor propagates all the way along the column, suggesting full ionization of the vapor. % We show that ionization occurs along the proton bunch, at the laser time and that the plasma that follows affects the proton bunch. %

physics.plasm-ph

The Two-Screen Measurement Setup to Indirectly Measure Proton Beam Self-Modulation in AWAKE

The goal of the first phase of the AWAKE \cite{AWAKE1,AWAKE2} experiment at CERN is to measure the self-modulation \cite{SMI} of the $σ_z = 12\,\rm{cm}$ long SPS proton bunch into microbunches after traversing $10\,\rm{m}$ of plasma with a plasma density of $n_{pe}=7\times10^{14}\,\rm{electrons/cm}^3$. The two screen measurement setup \cite{Turner2016} is a proton beam diagnostic that can indirectly prove the successful development of the self-modulation of the proton beam by imaging protons that got defocused by the transverse plasma wakefields after passing through the plasma, at two locations downstream the end of the plasma. This article describes the design and realization of the two screen measurement setup integrated in the AWAKE experiment. We discuss the performance and background response of the system based on measurements performed with an unmodulated Gaussian SPS proton bunch during the AWAKE beam commissioning in September and October 2016. We show that the system is fully commissioned and adapted to eventually image the full profile of a self-modulated SPS proton bunch in a single shot measurement during the first phase of the AWAKE experiment.

physics.acc-ph

Indirect Self-Modulation Instability Measurement Concept for the AWAKE Proton Beam

AWAKE, the Advanced Proton-Driven Plasma Wakefield Acceleration Experiment, is a proof-of-principle R&D experiment at CERN using a 400 GeV/c proton beam from the CERN SPS (longitudinal beam size sigma_z = 12 cm) which will be sent into a 10 m long plasma section with a nominal density of approx. 7x10^14 atoms/cm3 (plasma wavelength lambda_p = 1.2mm). In this paper we show that by measuring the time integrated transverse profile of the proton bunch at two locations downstream of the AWAKE plasma, information about the occurrence of the self-modulation instability (SMI) can be inferred. In particular we show that measuring defocused protons with an angle of 1 mrad corresponds to having electric fields in the order of GV/m and fully developed self-modulation of the proton bunch. Additionally, by measuring the defocused beam edge of the self-modulated bunch, information about the growth rate of the instability can be extracted. If hosing instability occurs, it could be detected by measuring a non-uniform defocused beam shape with changing radius. Using a 1 mm thick Chromox scintillation screen for imaging of the self-modulated proton bunch, an edge resolution of 0.6 mm and hence a SMI saturation point resolution of 1.2 m can be achieved.

physics.plasm-ph