SearcharxivSearch

arXiv subjects

S. Mohrdieck

Publications and source records attributed to S. Mohrdieck.

4 recordsLinked to original sources

Performance of the ATLAS Precision Muon Chambers under LHC Operating Conditions

For the muon spectrometer of the ATLAS detector at the large hadron collider (LHC), large drift chambers consisting of 6 to 8 layers of pressurized drift tubes are used for precision tracking covering an active area of 5000 m2 in the toroidal field of superconducting air core magnets. The chambers have to provide a spatial resolution of 41 microns with Ar:CO2 (93:7) gas mixture at an absolute pressure of 3 bar and gas gain of 2?104. The environment in which the chambers will be operated is characterized by high neutron and background with counting rates of up to 100 per square cm and second. The resolution and efficiency of a chamber from the serial production for ATLAS has been investigated in a 100 GeV muon beam at photon irradiation rates as expected during LHC operation. A silicon strip detector telescope was used as external reference in the beam. The spatial resolution of a chamber is degraded by 4 ?m at the highest background rate. The detection efficiency of the drift tubes is unchanged under irradiation. A tracking efficiency of 98% at the highest rates has been demonstrated.

physics.ins-det

Large-Scale Production of Monitored Drift Tube Chambers for the ATLAS Muon Spectrometer

Precision drift tube chambers with a sense wire positioning accuracy of better than 20 microns are under construction for the ATLAS muon spectrometer. 70% of the 88 large chambers for the outermost layer of the central part of the spectrometer have been assembled. Measurements during chamber construction of the positions of the sense wires and of the sensors for the optical alignment monitoring system demonstrate that the requirements for the mechanical precision of the chambers are fulfilled.

physics.ins-det

Precision Drift Chambers for the Atlas Muon Spectrometer

ATLAS is a detector under construction to explore the physics at the Large Hadron Collider at CERN. It has a muon spectrometer with an excellent momentum resolution of 3-10%, provided by three layers of precision monitored-drift-tube chambers in a toroidal magnetic field. A single drift tube measures a track point with a mean resolution close to 100 micron, even at the expected high neutron and gamma background rates. The tubes are positioned within the chamber with an accuracy of 20 microns, achieved by elaborate construction and assembly monitoring procedures.

physics.ins-det

Vector Mesons and pQCD at HERA

An overview of recent results from the H1 and ZEUS collaborations on vector meson production in electron-proton collisions at HERA is given. For diffractive vector meson production the energy dependence is discussed. The dependences on different scales, M_VM, Q^2 and |t|, are investigated. The data are compared to pQCD theoretical calculations. In addition new results on inelastic J/Psi electroproduction in a kinematical range 2<Q^2<100 GeV^2 and 50<W<225 GeV are shown. Differential cross sections are compared to theoretical predictions for color singlet and color octet contributions as well as to calculations for color singlet contributions alone.

hep-ex