SearcharxivSearch

arXiv subjects

S. Mufson

Publications and source records attributed to S. Mufson.

At least 19 recordsLinked to original sources

Differences in the response of two light guide technologies and two readout technologies after an exchange of liquid argon in the dewar

In this investigation the response to the scintillation light generated by through-going cosmic muons in liquid argon (LAr) was measured by two light guide technologies and two readout technologies after five weeks of running in the TallBo dewar at Fermilab. The response was remeasured after the dewar was drained of LAr, refilled, and then run again for an additional four weeks. After the dewar was refilled, there was clear evidence that the scintillation signal had dropped significantly. The two light guide technologies were developed at Indiana University and MIT/Fermilab. The two readout technologies were boards that passively or actively ganged 12 Hamamatsu MPPCs. Two possible explanations were identified for the degraded signal: the response of the two light guide technologies degraded due to damage caused by thermal cycling, and/or unknown differences in the trace residual Xe contamination in the fills of LAr led to the observed drop in scintillation light. Neither absorption nor quenching by N2, O2, and H2O contamination can account for the degradation. Neither the individual Hamamatsu MPPCs nor the passive/active ganging boards appear to have been affected by the thermal cycling. The path length distributions of the cosmics traversing the dewar appear quite similar in both event samples.

physics.ins-det

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for "far detectors" of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

physics.ins-det

New constraints on oscillation parameters from $ν_e$ appearance and $ν_μ$ disappearance in the NOvA experiment

We present updated results from the NOvA experiment for $ν_μ\rightarrowν_μ$ and $ν_μ\rightarrowν_e$ oscillations from an exposure of $8.85\times10^{20}$ protons on target, which represents an increase of 46% compared to our previous publication. The results utilize significant improvements in both the simulations and analysis of the data. A joint fit to the data for $ν_μ$ disappearance and $ν_e$ appearance gives the best fit point as normal mass hierarchy, $Δm^2_{32} = 2.44\times 10^{-3}{{\rm eV}^2}/c^4$, $\sin^2θ_{23} = 0.56$, and $δ_{CP} = 1.21π$. The 68.3% confidence intervals in the normal mass hierarchy are $Δm^2_{32} \in [2.37,2.52]\times 10^{-3}{{\rm eV}^2}/c^4$, $\sin^2θ_{23} \in [0.43,0.51] \cup [0.52,0.60]$, and $δ_{CP} \in [0,0.12π] \cup [0.91π,2π]$. The inverted mass hierarchy is disfavored at the 95% confidence level for all choices of the other oscillation parameters.

hep-ex

A Novel Use of Light Guides and Wavelength Shifting Plates for the Detection of Scintillation Photons in Large Liquid Argon Detectors

Scintillation light generated as charged particles traverse large liquid argon detectors adds valuable information to studies of weakly-interacting particles. This paper uses both laboratory measurements and cosmic ray data from the Blanche dewar facility at Fermilab to characterize the efficiency of the photon detector technology developed at Indiana University for the single phase far detector of DUNE. The efficiency of this technology was found to be 0.48% at the readout end when the detector components were characterized with laboratory measurements. A second determination of the efficiency using cosmic ray tracks is in reasonable agreement with the laboratory determination. The agreement of these two efficiency determinations supports the result that minimum ionizing muons generate ${\mathcal N}_{phot} = 40,000$ photons/MeV as they cross the LAr volume.

physics.ins-det

Photon detector system timing performance in the DUNE 35-ton prototype liquid argon time projection chamber

The 35-ton prototype for the Deep Underground Neutrino Experiment far detector was a single-phase liquid argon time projection chamber with an integrated photon detector system, all situated inside a membrane cryostat. The detector took cosmic-ray data for six weeks during the period of February 1, 2016 to March 12, 2016. The performance of the photon detection system was checked with these data. An installed photon detector was demonstrated to measure the arrival times of cosmic-ray muons with a resolution better than 32 ns, limited by the timing of the trigger system. A measurement of the timing resolution using closely-spaced calibration pulses yielded a resolution of 15 ns for pulses at a level of 6 photo-electrons. Scintillation light from cosmic-ray muons was observed to be attenuated with increasing distance with a characteristic length of $155 \pm 28$ cm.

physics.ins-det

Liquid scintillator production for the NOvA experiment

The NOvA collaboration blended and delivered 8.8 kt (2.72M gal) of liquid scintillator as the active detector medium to its near and far detectors. The composition of this scintillator was specifically developed to satisfy NOvA's performance requirements. A rigorous set of quality control procedures was put in place to verify that the incoming components and the blended scintillator met these requirements. The scintillator was blended commercially in Hammond, IN. The scintillator was shipped to the NOvA detectors using dedicated stainless steel tanker trailers cleaned to food grade.

physics.ins-det

Summary of the Second Workshop on Liquid Argon Time Projection Chamber Research and Development in the United States

The second workshop to discuss the development of liquid argon time projection chambers (LArTPCs) in the United States was held at Fermilab on July 8-9, 2014. The workshop was organized under the auspices of the Coordinating Panel for Advanced Detectors, a body that was initiated by the American Physical Society Division of Particles and Fields. All presentations at the workshop were made in six topical plenary sessions: $i)$ Argon Purity and Cryogenics, $ii)$ TPC and High Voltage, $iii)$ Electronics, Data Acquisition and Triggering, $iv)$ Scintillation Light Detection, $v)$ Calibration and Test Beams, and $vi)$ Software. This document summarizes the current efforts in each of these areas. It primarily focuses on the work in the US, but also highlights work done elsewhere in the world.

physics.ins-det

Liquid Argon Time Projection Chamber Research and Development in the United States

A workshop was held at Fermilab on March 20-21, 2013 to discuss the development of liquid argon time projection chambers (LArTPC) in the United States. The workshop was organized under the auspices of the Coordinating Panel for Advanced Detectors, a body that was initiated by the American Physical Society Division of Particles and Fields. All presentations at the workshop were made in plenary sessions organized into seven topical categories: $i)$ Argon Purity, $ii)$ Cryogenics, $iii)$ TPC and High Voltage, $iv)$ Electronics, Data Acquisition and Triggering, $v)$ Scintillation Light Detection, $vi)$ Calibration and Test Beams, and $vii)$ Software. This document summarizes the current efforts in each of these topical categories. It also highlights areas in LArTPC research and development that are common between neutrino experiments and dark matter experiments.

physics.ins-det

Benchmarking TPB-coated Light Guides for Liquid Argon TPC Light Detection Systems

Scintillation light from liquid argon is produced at 128 nm and thus must be shifted to visible wavelengths in light detection systems used for Liquid Argon Time Projection Chambers (LArTPCs). To date, designs have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we show that the response of lightguides coated with TPB in a UV Transmitting (UVT) acrylic matrix is very similar to that of a coating using a polystyrene (PS) matrix. We obtain a factor of three higher light yield than has been previously reported from lightguides. This paper provides information on the response of the lightguides so that these can be modeled in simulations for future LArTPCs. This paper also identifies areas of R&D for potential improvements in the lightguide response

physics.ins-det

The CAPTAIN Detector and Physics Program

The Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrino (CAP- TAIN) program is designed to make measurements of scientific importance to long-baseline neutrino physics and physics topics that will be explored by large underground detectors. The CAPTAIN detector is a liquid argon TPC deployed in a portable and evacuable cryostat. Five tons of liquid argon are instrumented with a 2,000 channel liquid argon TPC and a photon detection system. Subsequent to the commissioning phase, the detector will collect data in a high-energy neutron beamline that is part of the Los Alamos Neutron Science Center to measure cross-sections of spallation products that are backgrounds to measurements of neutrinos from a supernova burst, cross-sections of events that mimic the electron neutrino appearance signal in long-baseline neutrino physics and neutron signatures to constrain neutrino energy reconstruction in LBNE's long-baseline program. Subsequent to the neutron running, the CAPTAIN detector will be moved to a neutrino source. Two possibilities are an on-axis run in the NuMI beamline at FNAL and a run in the neutrino source produced by the SNS. An on-axis run at NuMI produces more than one million events of interest in a two or three year run at neutrino energies between 1 and 10 GeV - complementary to the MicroBooNE experiment, which will measure similar interactions at a lower energy range - 0.5 to 2 GeV. At the SNS the neutrinos result from the decays stopped positively charged pions and muons yielding a broad spectrum up to 50 MeV. If located close to the spallation target, CAPTAIN can detect several thousand events per year in the same neutrino energy regime where neutrinos from a supernova burst are. Measurements at the SNS yield a first measurement of the cross- section of neutrinos on argon in this important energy regime.

physics.ins-det

A search for flavor-changing non-standard neutrino interactions by MINOS

We report new constraints on flavor-changing non-standard neutrino interactions (NSI) using data from the MINOS experiment. We analyzed a combined set of beam neutrino and antineutrino data, and found no evidence for deviations from standard neutrino mixing. The observed energy spectra constrain the NSI parameter to the range $-0.20 < \varepsilon_{μτ} < 0.07\;\text{(90% C.L.)}$

hep-ex

The Search for Neutrino-Antineutrino Mixing Resulting from Lorentz Invariance Violation using neutrino interactions in MINOS

We searched for a sidereal modulation in the rate of neutrinos produced by the NuMI beam and observed by the MINOS far detector. The detection of such harmonic signals could be a signature of neutrino-antineutrino mixing due to Lorentz and CPT violation as described by the Standard Model Extension framework. We found no evidence for these sidereal signals and we placed limits on the coefficients in this theory describing the effect. This is the first report of limits on these neutrino-antineutrino mixing coefficients.

hep-ex

Measurements of atmospheric neutrinos and antineutrinos in the MINOS Far Detector

This paper reports measurements of atmospheric neutrino and antineutrino interactions in the MINOS Far Detector, based on 2553 live-days (37.9 kton-years) of data. A total of 2072 candidate events are observed. These are separated into 905 contained-vertex muons and 466 neutrino-induced rock-muons, both produced by charged-current $ν_μ$ and $\barν_μ$ interactions, and 701 contained-vertex showers, composed mainly of charged-current $ν_{e}$ and $\barν_{e}$ interactions and neutral-current interactions. The curvature of muon tracks in the magnetic field of the MINOS Far Detector is used to select separate samples of $ν_μ$ and $\barν_μ$ events. The observed ratio of $\barν_μ$ to $ν_μ$ events is compared with the Monte Carlo simulation, giving a double ratio of $R^{data}_{\barν/ν}/R^{MC}_{\barν/ν} = 1.03 \pm 0.08 (stat.) \pm 0.08 (syst.)$. The $ν_μ$ and $\barν_μ$ data are separated into bins of $L/E$ resolution, based on the reconstructed energy and direction of each event, and a maximum likelihood fit to the observed $L/E$ distributions is used to determine the atmospheric neutrino oscillation parameters. This fit returns 90% confidence limits of $|Δm^{2}| = (1.9 \pm 0.4) \times 10^{-3} eV^{2}$ and $sin^{2} 2θ> 0.86$. The fit is extended to incorporate separate $ν_μ$ and $\barν_μ$ oscillation parameters, returning 90% confidence limits of $|Δm^{2}|-|Δ\bar{m}^{2}| = 0.6^{+2.4}_{-0.8} \times 10^{-3} eV^{2}$ on the difference between the squared-mass splittings for neutrinos and antineutrinos.

hep-ex

An improved measurement of muon antineutrino disappearance in MINOS

We report an improved measurement of muon anti-neutrino disappearance over a distance of 735km using the MINOS detectors and the Fermilab Main Injector neutrino beam in a muon anti-neutrino enhanced configuration. From a total exposure of 2.95e20 protons on target, of which 42% have not been previously analyzed, we make the most precise measurement of the anti-neutrino "atmospheric" delta-m squared = 2.62 +0.31/-0.28 (stat.) +/- 0.09 (syst.) and constrain the anti-neutrino atmospheric mixing angle >0.75 (90%CL). These values are in agreement with those measured for muon neutrinos, removing the tension reported previously.

hep-ex

Search for Lorentz invariance and CPT violation with muon antineutrinos in the MINOS Near Detector

We have searched for sidereal variations in the rate of antineutrino interactions in the MINOS Near Detector. Using antineutrinos produced by the NuMI beam, we find no statistically significant sidereal modulation in the rate. When this result is placed in the context of the Standard Model Extension theory we are able to place upper limits on the coefficients defining the theory. These limits are used in combination with the results from an earlier analysis of MINOS neutrino data to further constrain the coefficients.

hep-ex

Search for the disappearance of muon antineutrinos in the NuMI neutrino beam

We report constraints on antineutrino oscillation parameters that were obtained by using the two MINOS detectors to measure the 7% muon antineutrino component of the NuMI neutrino beam. In the Far Detector, we select 130 events in the charged-current muon antineutrino sample, compared to a prediction of 136.4 +/- 11.7(stat) ^{+10.2}_{-8.9}(syst) events under the assumption |dm2bar|=2.32x10^-3 eV^2, snthetabar=1.0. Assuming no oscillations occur at the Near Detector baseline, a fit to the two-flavor oscillation approximation constrains |dm2bar|<3.37x10^-3 eV^2 at the 90% confidence level with snthetabar=1.0.

hep-ex

First direct observation of muon antineutrino disappearance

This letter reports the first direct observation of muon antineutrino disappearance. The MINOS experiment has taken data with an accelerator beam optimized for muon antineutrino production, accumulating an exposure of $1.71\times 10^{20}$ protons on target. In the Far Detector, 97 charged current muon antineutrino events are observed. The no-oscillation hypothesis predicts 156 events and is excluded at $6.3σ$. The best fit to oscillation yields $Δ\bar{m}^{2}=(3.36^{+0.46}_{-0.40}\textrm{(stat.)}\pm0.06\textrm{(syst.)})\times 10^{-3}\,\eV^{2}$, $\sin^{2}(2\barθ)=0.86^{+0.11}_{-0.12}\textrm{(stat.)}\pm0.01\textrm{(syst.)}$. The MINOS muon neutrino and muon antineutrino measurements are consistent at the 2.0% confidence level, assuming identical underlying oscillation parameters.

hep-ex

Improved search for muon-neutrino to electron-neutrino oscillations in MINOS

We report the results of a search for $ν_{e}$ appearance in a $ν_μ$ beam in the MINOS long-baseline neutrino experiment. With an improved analysis and an increased exposure of $8.2\times10^{20}$ protons on the NuMI target at Fermilab, we find that $2\sin^2(θ_{23})\sin^2(2θ_{13})<0.12\ (0.20)$ at 90% confidence level for $δ\mathord{=}0$ and the normal (inverted) neutrino mass hierarchy, with a best fit of $2\sin^2(θ_{23})\sin^2(2θ_{13})\,\mathord{=}\,0.041^{+0.047}_{-0.031}\ (0.079^{+0.071}_{-0.053})$. The $θ_{13}\mathord{=}0$ hypothesis is disfavored by the MINOS data at the 89% confidence level.

hep-ex