SearcharxivSearch

arXiv subjects

S. Parzych

Publications and source records attributed to S. Parzych.

10 recordsLinked to original sources

Studies of CPT symmetry in positronium decays with 192 plastic strip J-PET detector

A direct test of the CPT symmetry is performed for the electromagnetic decays of ortho-positronium using the J-PET tomograph. We present the precise measurement of the CPT-sensitive angular correlation entailing the positronium spin and the momenta of its annihilation photons, surpassing previous studies utilizing the same detection system. Positrons originating from a $^{22}$Na source are emitted from the detector's center and subsequently form positronium atoms within the spherical chamber covered with porous material. Reconstruction of annihilation locations using the 192-strip J-PET detector makes it possible to determine the positronium emission direction, which defines the quantization axis along which positronium is polarized, without the application of external magnetic fields. The measurements were performed in total for 356 days resulting in an identification of 47.8 million events with ortho-positronium decays into three photons. The results are consistent with the exactness of CPT symmetry with measured asymmetry amplitude -0.00029 $\pm$ 0.00022 (stat.) and with statistical error four times smaller than the previous best measurement.

nucl-ex

Nanoporosity imaging by positronium lifetime tomography

Positron Annihilation Lifetime Spectroscopy (PALS) is a well-established non-destructive technique used for nanostructural characterization of porous materials. It is based on the annihilation of a positron and an electron. Mean positron lifetime in the material depends on the free voids size and molecular environment, allowing the study of porosity and structural transitions in the nanometer scale. We have developed a novel method enabling spatially resolved PALS, thus providing tomography of nanostructural characterization of an extended object. Correlating space (position) and structural (lifetime) information brings new insight in materials studies, especially in the characterization of the purity and pore distribution. For the first time, a porosity image using stationary positron sources for the simultaneous measurement of the porous polymers XAD4, silica aerogel powder IC3100, and polyvinyl toluene scintillator PVT by the J-PET tomograph is demonstrated

physics.app-ph

Investigation of Novel Preclinical Total Body PET Designed With J-PET Technology:A Simulation Study

The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment monitoring, animal-based research became a necessary step for testing and protocol preparation. In this simulation-based study two unconventional, cost-effective small animal total body PET scanners (for mouse and rat studies) have been investigated in order to inspect their feasibility for preclinical research. They were designed with the novel technology explored by the Jagiellonian-PET (J-PET) Collaboration. Two main PET characteristics: sensitivity and spatial resolution were mainly inspected to evaluate their performance. Moreover, the impact of the scintillator dimension and time-of-flight on the latter parameter was examined in order to design the most efficient tomographs. The presented results show that for mouse TB J-PET the achievable system sensitivity is equal to 2.35% and volumetric spatial resolution to 9.46 +- 0.54 mm3, while for rat TB J-PET they are equal to 2.6% and 14.11 +- 0.80 mm3, respectively. Furthermore, it was shown that the designed tomographs are almost parallax-free systems, hence, they resolve the problem of the acceptance criterion tradeoff between enhancing spatial resolution and reducing sensitivity.

physics.med-ph

Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner

Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the transparency of long plastic scintillators with dimensions 6 mm x 24 mm x 1000 mm and with all surfaces polished. Six different types of commercial, general purpose, blue-emitting plastic scintillators with low attenuation of visible light were tested, namely: polyvinyl toluene-based BC-408, EJ-200, RP-408, and polystyrene-based Epic, SP32 and UPS-923A. For determination of the best type of plastic scintillator for totalbody Jagiellonian positron emission tomograph (TB-J-PET) construction, emission and transmission spectra, and technical attenuation length (TAL) of blue light-emitting by the scintillators were measured and compared. The TAL values were determined with the use of UV lamp as excitation source, and photodiode as light detector. Emission spectra of investigated scintillators have maxima in the range from 420 nm to 429 nm. The BC-408 and EJ-200 have the highest transmittance values of about 90% at the maximum emission wavelength measured through a 6 mm thick scintillator strip and the highest technical attenuation length reaching about 2000 mm, allowing assembly of long detection modules for time-of-flight (TOF) J-PET scanners. Influence of the 6 mm x 6 mm, 12 mm x 6 mm, 24 mm x 6 mm cross-sections of the 1000 mm long EJ-200 plastic scintillator on the TAL and signal intensity was measured. The highest TAL value was determined for samples with 24 mm x 6 mm cross-section.

physics.ins-det

Non-maximal entanglement of photons from positron-electron annihilation demonstrated using a novel plastic PET scanner

In state-of-the-art Positron Emission Tomography (PET), information about annihilation photon polarization is unavailable. Here, we present a PET scanner built from plastic scintillators, where annihilation photons primarily interact via the Compton effect, providing information about both photon polarization and propagation direction. Using this plastic-based PET, we determined the distribution of the relative angle between polarization planes of photons from positron-electron annihilation in a porous polymer. The amplitude of the observed distribution is smaller than predicted for maximally quantum-entangled two-photon states but larger than expected for separable photons. This result can be well explained by assuming that photons from pick-off annihilation are not entangled, while photons from direct and para-positronium annihilations are maximally entangled. Our result indicates that the degree of entanglement depends on the annihilation mechanism in matter, opening new avenues for exploring polarization correlations in PET as a diagnostic indicator.

nucl-ex

Feasibility studies for imaging e$^{+}$e$^{-}$ annihilation with modular multi-strip detectors

Studies based on imaging the annihilation of the electron (e$^{-}$) and its antiparticle positron (e$^{+}$) open up several interesting applications in nuclear medicine and fundamental research. The annihilation process involves both the direct conversion of e$^{+}$e$^{-}$ into photons and the formation of their atomically bound state, the positronium atom (Ps), which can be used as a probe for fundamental studies. With the ability to produce large quantities of Ps, manipulate them in long-lived Ps states, and image their annihilations after a free fall or after passing through atomic interferometers, this purely leptonic antimatter system can be used to perform inertial sensing studies in view of a direct test of Einstein equivalence principle. It is envisioned that modular multistrip detectors can be exploited as potential detection units for this kind of studies. In this work, we report the results of the first feasibility study performed on a e$^{+}$ beamline using two detection modules to evaluate their reconstruction performance and spatial resolution for imaging e$^{+}$e$^{-}$ annihilations and thus their applicability for gravitational studies of Ps.

physics.ins-det

TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix

We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for TOF, parallax effect and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static XCAT phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images and ground truth metrics. We also reconstructed the data with additive contributions, pre-filtered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalise on the realistic RM with better edge preservation and superior ground truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multi-photon imaging and further upgrade to account for the non-collinearity, positron range and other factors.

physics.med-ph

J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams

The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 plastic scintillators arranged in 3 layers has been optimized for the study of positronium decays. This allows performing precision tests of discrete symmetries (C, P, T) in the decays of positronium atoms. Moreover, thanks to the possibility of measuring the polarization direction of the photon based on Compton scattering, the predicted entanglement between the linear polarization of annihilation photons in positronium decays can also be studied. Recently, a new J-PET prototype was commissioned, based on a modular design of detection units. Each module consists of 13 plastic scintillators and can be used as a stand-alone, compact and portable detection unit. In this paper, the main features of the J-PET detector, the modular prototype and their applications for possible studies with positron and positronium beams are discussed. Preliminary results of the first test experiment performed on two detection units in the continuous positron beam recently developed at the Antimatter Laboratory (AML) of Trento are also reported.

physics.ins-det

Upper limit on the $\eta\to\pi^{+}\pi^{-}$ branching fraction with the KLOE experiment

Based on an integrated luminosity of 1.61 fb$^{-1}$ $e^+e^-$ collision data collected with the KLOE detector at DA$\Phi$NE, the Frascati $\phi$-factory, a search for the $P$- and $CP$-violating decay $\eta\to\pi^{+}\pi^{-}$ has been performed. Radiative $\phi\to\eta\gamma$ decay is exploited to access the $\eta$ mesons. No signal is observed in the $\pi^{+}\pi^{-}$ invariant mass spectrum, and the upper limit on the branching fraction at 90\% confidence level is determined to be ${\mathcal B}(\eta\to\pi^{+}\pi^{-})<4.9\times10^{-6}$, which is approximately three times smaller than the previous KLOE result. From the combination of these two measurements we get ${\mathcal B}(\eta\to\pi^{+}\pi^{-}) < 4.4\times10^{-6}$ at 90\% confidence level.

hep-ex

Measurement of the branching fraction for the decay $K_S \to \pi \mu \nu$ with the KLOE detector

Based on a sample of 300 million $K_S$ mesons produced in $\phi \to K_L K_S$ decays recorded by the KLOE experiment at the DA$\Phi$NE $e^+e^-$ collider we have measured the branching fraction for the decay $K_S \to \pi \mu \nu$. The $K_S$ mesons are identified by the interaction of $K_L$ mesons in the detector. The $K_S \to \pi \mu \nu$ decays are selected by a boosted decision tree built with kinematic variables and by a time-of-flight measurement. Signal efficiencies are evaluated with data control samples of $K_L \to \pi \mu \nu$ decays. A fit to the reconstructed muon mass distribution finds $7223 \pm 180$ signal events. Normalising to the $K_S \to \pi^+ \pi^-$ decay events the result for the branching fraction is $\mathcal{B}(K_S \to \pi \mu \nu) = (4.56 \pm 0.11_{\rm stat} \pm 0.17_{\rm syst})\times10^{-4}$.

hep-ex