SearcharxivSearch

arXiv subjects

S. Quitadamo

Publications and source records attributed to S. Quitadamo.

At least 19 recordsLinked to original sources

A microwave SQUID multiplexing concept for macro-cryogenic calorimeter arrays

Massive cryogenic calorimeters read out by transition-edge sensors (TES) can reach eV-scale baseline resolution, but the single-channel dc-SQUID readout conventionally used in rare-event searches, with one amplifier chain and several wires per detector, limits practical arrays to a few tens of channels. We propose to apply microwave SQUID multiplexing ($\mu$MUX), developed for fast X-ray and neutrino-mass microcalorimeters, to massive BGO (Bi$_4$Ge$_3$O$_{12}$) calorimeters operated at $\simeq 20$~mK; sapphire and TeO$_2$ absorbers are covered by the same framework. Using the established thermal and noise model for massive TES calorimeters, we derive a noise model for the multiplexed readout, including the HEMT, two-level-system and SQUID contributions, and its scaling with the multiplexing factor $N_{\rm mux}$. Since the slow thermal signals require only about a kHz of sampling per channel, the limiting requirement is not bandwidth but an input-coil sensitivity of $( 0.1$ to $1)\,\mu$A$/\Phi_0$, a factor of $10$ to $30$ beyond current $\mu$MUX devices, matched to the detector current noise of ($9$ to $10$)~pA$/\sqrt{\rm Hz}$, which is independent of the absorber mass. With a total flux noise of $\simeq$$1.2\,\mu\Phi_0/\sqrt{\rm Hz}$, the readout degrades the baseline resolution by less than $2\%$ up to $N_{\rm mux}=1000$, negligible compared with the TES-limited resolution. These results are implemented in a single-tower design: 52 BGO crystals of 100~g each and one HEMT amplifier. The tower is the unit of a multi-tower array of several kilograms aimed at CE$\nu$NS and dark matter searches.

physics.ins-det

Solar axion searches with RES-NOVA: projected sensitivity and first prototype limit

RES-NOVA is a cryogenic experiment based on PbWO4 scintillating bolometers produced from archaeological lead, originally designed to detect coherent elastic neutrino-nucleus scattering (CEvNS) from galactic core-collapse supernovae. We show that the same high-density, high-Z absorbers and sub-keV energy resolution make RES-NOVA an appealing probe of solar axions. We compute the expected signal from the Primakoff, ABC (atomic recombination and de-excitation, Bremsstrahlung, Compton), longitudinal-plasmon (LP), and 57Fe nuclear-line components of the solar axion flux, folded through the inverse-Primakoff and axioelectric detection channels in PbWO4, which probe the axion couplings to photons (g_a-gamma), electrons (g_ae), and nucleons (g_aN), respectively. We derive projected sensitivities for a 1 ton*y exposure of the RES-NOVA demonstrator in the (g_ae,g_a-gamma), (g_ae,g_aN), and (g_a-gamma,g_aN) planes. The projected reach in g_ae approaches that of XENONnT to within a factor of ~2, despite a background roughly four orders of magnitude higher, thanks to the large target mass, the high-Z enhancement of the axioelectric and inverse-Primakoff cross sections, and the sub-keV energy resolution. Because the inverse-Primakoff constraint on g_a-gamma relies on absorption rather than coherent conversion, it is independent of the axion mass, unlike bounds from magnetic helioscopes. We complement these projections with the first solar-axion exclusion limit obtained on real data with a 13 g PbWO4 prototype grown from archaeological lead, using a background-model-independent optimum-interval analysis. These results establish RES-NOVA as a promising multi-coupling probe of solar axions, with simultaneous sensitivity to g_ae, g_a-gamma and g_aN that is complementary to existing helioscope and direct-detection searches.

hep-ex

Probing large mass-splitting inelastic Dark Matter with RES-NOVA

Probing inelastic dark matter at large mass splittings requires heavy target nuclei, an extended recoil-energy range, and the high-velocity tail of the dark-matter distribution. We exploit these features with the RES-NOVA prototype detector, featuring a PbWO4 cryogenic calorimeter, produced from archaeological Pb and operated at the deep-underground laboratory of Gran Sasso of INFN (Italy), analyzing a 32.4 g day exposure over 2.5 keV - 1 MeV under both the Standard Halo Model (SHM) and a Large Magellanic Cloud (LMC)-motivated velocity distribution. We extend direct-detection constraints beyond the 330 keV reach of established technologies (e.g. Xe-based TPCs), probing splittings up to 510 (780) keV in the SHM (LMC) benchmark, while future exposures will probe new regions of the parameter space.

astro-ph.CO

Neutrino NSI in archaeological Pb

Dark matter direct detection experiments can observe solar neutrinos via coherent elastic neutrino-nucleus scattering, making it possible to test new physics in the neutrino sector. In this article, we study the sensitivity of RES-NOVA, a novel cryogenic calorimetric experiment employing PbWO$_4$ crystals grown from archaeological lead, to neutrino non-standard interactions (NSI). We perform a sensitivity study for a benchmark setup with a nominal energy threshold of 1 keV and an exposure of 1 ton$\cdot$y, both for a conservative (only heat readout) and ideal (heat and scintillation) background rejection scenario. We find that, in its nominal configuration, while not being sensitive to Standard Model solar $\nu$ interactions, RES-NOVA can reach sensitivities to NSI at the level of current global fits. With moderate or significant improvements of the threshold down to $0.5$ keV and $0.2$ keV, RES-NOVA will be able to achieve sensitivities beyond NSI global fit results, testing new areas of the parameter space in the electron and tau sectors, $\varepsilon_{ee}$, $\varepsilon_{\tau\tau}$, and $\varepsilon_{e\tau}$. A similar improvement in sensitivities is expected when instead increasing the exposure to 10 ton$\cdot$y.

hep-ph

A rapid low-background assay of $^{210}$Pb in archaeological lead

In this work, we present a fast and highly efficient method for the measurement of $^{210}$Pb in metallic archaeological lead using the commercial low-background liquid scintillation counter Wallac Quantulus 1220 installed at the University of Milano-Bicocca (Italy). By combining an optimized chemical preparation with pulse-shape analysis (PSA), the technique achieves sensitivities at the level of a few $10^2$ mBq/kg within one week of measurement, using sample masses below 1 g. The method enables the simultaneous identification of the $\beta$ decays of $^{210}$Pb and $^{210}$Bi and the $\alpha$ decay of $^{210}$Po, allowing a direct verification of secular equilibrium within the decay chain. With extended acquisition times, detection limits below 100 mBq/kg are reached after approximately 40 days. This approach provides a rapid, accessible, and reliable tool for the radiopurity screening of lead, and is well suited for quality control and R&D activities in next-generation low-background and rare-event physics experiments. Moreover, the method has the potential to be extended to other materials relevant for low-background applications.

physics.ins-det

Probing dark matter interactions with a RES-NOVA prototype cryogenic detector

We report on the operation of a 13 g PbWO$_4$ crystal, grown from archaeological Pb and operated as a cryogenic calorimeter in an underground environment. Read out with a Ge thermistor, the detector achieves a low energy threshold and, for the first time, enables the derivation of a dark matter exclusion limit using PbWO$_4$ as target material, for both spin-dependent interactions on neutrons and spin-independent interactions. Although limited in mass and not representative of the final RES-NOVA detector design, this prototype demonstrates effective control of mechanical vibrations and low-energy noise in a cryogenic system, which is a key requirement for rare-event searches. The experiment therefore provides a proof of principle for the RES-NOVA detection concept, validating the use of archaeological Pb-based PbWO$_4$ crystals, low-background operation, and robust data-analysis procedures. These results establish a solid technological and methodological foundation for future RES-NOVA detectors employing larger target masses and advanced thermal readout technologies.

physics.ins-det

End-to-End Data Analysis Methods for the CUORE Experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) experiment set the most stringent limit on the neutrinoless double-beta ($0\nu\beta\beta$) decay half-life of $^{130}$Te with 2 ton yr TeO$_2$ analyzed exposure. In addition to $0\nu\beta\beta$ decay, the CUORE detector -- a ton-scale array of nearly 1000 cryogenic calorimeters operating at $\sim$10 mK -- is capable of searching for other rare decays and interactions over a broad energy range. For our searches, we leverage the available information of each calorimeter by performing its optimization, data acquisition, and analysis independently. We describe the analysis tools and methods developed for CUORE and their application to build high-quality datasets for numerous physics searches. In particular, we describe in detail our evaluation of the energy-dependent detector response and signal efficiency used in the most recent search for $0\nu\beta\beta$ decay.

nucl-ex

Reconstruction of cosmic-ray muon events with CUORE

We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta ($0\nu\beta\beta$) decay, leveraging the segmentation of the detector. Due to the slow time response of the detector, time-of-flight estimation is not feasible. Therefore, the track reconstruction is performed using a multi-objective optimization algorithm that relies on geometrical information from the detector as a whole. We measure the integral flux of cosmic-ray muons underground at the {\it Laboratori Nazionali del Gran Sasso}, and find our value to be in good agreement with other experiments that have performed a similar measurement. To our knowledge, this work represents the first demonstration of 3D particle tracking and reconstruction of through-going muons with per-event angular determination in a millikelvin cryogenic detector array. The analysis performed for this work will be critical for validating the muon-related background in CUPID, a next-generation $0\nu\beta\beta$ experiment, and for follow-up studies on detector response and on delayed products induced by cosmic-ray muons.

physics.ins-det

Exploring the keV-scale physics potential of CUORE

We present the analysis techniques developed to explore the keV-scale energy region of the CUORE experiment, based on more than 2 tonne yr of data collected over 5 years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data taking conditions. We achieve an average baseline resolution of 2.54 $\pm$ 0.14 keV FWHM and 1.18 $\pm$ 0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06 $\pm$ 0.05 counts/(keV kg days) and 16 $\pm$ 2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 26 $\pm$ 4 \% and 50 $\pm$ 2 \% at 3 keV and 10 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that tonne-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.

hep-ex

The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment

Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ($0\nu\beta\beta$) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here we report the first detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for $0\nu\beta\beta$ decay with mK-scale calorimeters and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE's energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to $0\nu\beta\beta$ decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.

physics.ins-det

Half-life and precision shape measurement of 2{\nu}{\beta}{\beta} decay of $^{130}$Te

We present a new measurement of the 2nbb half-life of 130Te (T1/2) using the first complete model of the CUORE data, based on 1038 kg yr of collected exposure. Thanks to optimized data selection, we achieve a factor of two improvement in precision, obtaining T1/2 = (9.32 +0.05 -0.04 (stat.) +0.07 -0.07 (syst.)) x10^20 yr. The signal-to-background ratio is increased by 70% compared to our previous results, enabling the first application of the improved 2nbb formalism to 130Te. Within this framework, we determine a credibility interval for the effective axial coupling in the nuclear medium as a function of nuclear matrix elements. We also extract values for the higher-order nuclear matrix element ratios: second-to-first and third-to-first. The second-to-first ratio agrees with nuclear model predictions, while the third-to-first ratio deviates from theoretical expectations. These findings provide essential tests of nuclear models and key inputs for future 0nbb searches.

nucl-ex

A new dark matter direct search based on archaeological Pb

The RES-NOVA project is an experimental initiative aimed at detecting neutrinos from the next galactic supernova using PbWO$_{4}$ cryogenic detectors, operated at low temperatures in a low-background environment. By utilizing archaeological lead (Pb) as the target material, RES-NOVA leverages its high radiopurity, large nuclear mass, and the natural abundance of $^{207}$Pb, making it well-suited for exploring both spin-independent and spin-dependent Dark Matter (DM) interactions via nuclear scattering. This work presents a background model developed for the RES-NOVA technology demonstrator and evaluates its implications for Dark Matter detection. Detailed calculations of nuclear matrix elements, combined with the unique properties of archaeological Pb, demonstrate RES-NOVA's potential as a complementary tool to existing direct detection experiments for studying Dark Matter interactions. The experiment will conduct DM searches over a broad mass range spanning 4 orders of magnitude, from sub-GeV/$c^2$ to TeV/$c^2$. In the most optimistic scenario, RES-NOVA is expected to probe DM-nucleon cross-sections down to 1$\times 10^{-43}$ cm$^2$ and 2$\times 10^{-46}$ cm$^2$ for candidates with masses of 2 GeV/$c^2$ and 20 GeV/$c^2$, respectively.

physics.ins-det

Search for fractionally charged particles with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using the first tonne-year of CUORE's exposure, we perform a search for hypothesized fractionally charged particles (FCPs), which are well-motivated by various Standard Model extensions and would have suppressed interactions with matter. No excess of FCP candidate tracks is observed over background, setting leading limits on the underground FCP flux with charges between $e/24-e/5$ at 90\% confidence level. Using the low background environment and segmented geometry of CUORE, we establish the sensitivity of tonne-scale sub-Kelvin detectors to diverse signatures of new physics.

hep-ex

Data-driven background model for the CUORE experiment

We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth exploration of both spatial and time dependence of backgrounds. We achieve high sensitivity to both bulk and surface activities of the materials of the setup, detecting levels as low as 10 nBq kg$^{-1}$ and 0.1 nBq cm$^{-2}$, respectively. We compare the contamination levels we extract from the background model with prior radio-assay data, which informs future background risk mitigation strategies. The results of this background model play a crucial role in constructing the background budget for the CUPID experiment as it will exploit the same CUORE infrastructure.

nucl-ex

The environmental low-frequency background for macro-calorimeters at the millikelvin scale

Many of the most sensitive physics experiments searching for rare events, like neutrinoless double beta ($0\nu\beta\beta$) decay and dark matter interactions, rely on cryogenic macro-calorimeters operating at the mK-scale. Located underground at the Gran Sasso National Laboratory (LNGS), in central Italy, CUORE (Cryogenic Underground Observatory for Rare Events) is one of the leading experiments for the search of $0\nu\beta\beta$ decay, implementing the low-temperature calorimetric technology. We present a novel multi-detector analysis to correlate environmental phenomena with the low-frequency noise of low-temperature calorimeters. Indeed, the correlation of marine and seismic data with data from a pair of CUORE detectors indicates that cryogenic detectors are sensitive not only to intense vibrations generated by earthquakes, but also to the much fainter vibrations induced by marine microseisms in the Mediterranean Sea due to the motion of sea waves. Proving that cryogenic macro-calorimeters are sensitive to such environmental sources of noise opens the possibility of studying their impact on the detectors physics-case sensitivity. Moreover, this study could pave the road for technology developments dedicated to the mitigation of the noise induced by marine microseisms, from which the entire community of cryogenic calorimeters can benefit.

physics.ins-det

Constraints on Lepton Number Violation with the 2 tonne$\cdot$yr CUORE Dataset

Matter-antimatter asymmetry underlines the incompleteness of the current understanding of particle physics. Neutrinoless double-beta decay ($0\nu \beta\beta$) may help explain this asymmetry, while unveiling the Majorana nature of the neutrino. The CUORE experiment searches for $0\nu \beta\beta$ of $^{130}$Te using a tonne-scale cryogenic calorimeter operated at milli-kelvin temperatures. We report no evidence of $0\nu \beta\beta$ and place a lower limit on the half-life of $T_{1/2} >3.5 \times$ 10$^{25}$~years (90\% C.I.) with over 2~tonne$\cdot$year TeO$_2$ exposure. The tools and techniques developed for this result and the 5 year stable operation of nearly 1000 detectors demonstrate crucial infrastructure for a future-generation experiment capable of searching for $0\nu \beta\beta$ across multiple isotopes.

nucl-ex

Simultaneous Measurement of Half-Life and Spectral Shape of $^{115}$In $\beta$-decay with an Indium Iodide Cryogenic Calorimeter

Current bounds on neutrino Majorana mass are affected by significant uncertainties in the nuclear calculations for neutrinoless double-beta decay. A key issue for a data-driven improvement of the nuclear theory is the actual value of the axial coupling constant $g_A$, which can be investigated through forbidden $\beta$-decays. We present the first measurement of 4$^{th}$-forbidden $\beta$-decay of $^{115}$In with a cryogenic calorimeter based on Indium Iodide. Exploiting the enhanced spectral shape method for the first time to this isotope, our study accurately determines simultaneously spectral shape, $g_A$, and half-life. The Interacting Shell Model, which best fits our data, indicates a half-life for this decay at $T_{1/2}=(5.26\pm0.06) \times 10^{14}$,yr.

nucl-ex

Array of Cryogenic Calorimeters to Evaluate the Spectral Shape of forbidden $β$-decays: the ACCESS project

The ACCESS (Array of Cryogenic Calorimeters to Evaluate Spectral Shapes) project aims to establish a novel technique to perform precision measurements of forbidden \b{eta}-decays, which can serve as an important benchmark for nuclear physics calculations and represent a significant background in astroparticle physics experiments. ACCESS will operate a pilot array of cryogenic calorimeters based on natural and doped crystals containing \b{eta}-emitting radionuclides. In this way, natural (e.g. 113 Cd and 115In) and synthetic isotopes (e.g. 99Tc) will be simultaneously measured with a common experimental technique. The array will also include further crystals optimised to disentangle the different background sources, thus reducing the systematic uncertainty. In this paper, we give an overview of the ACCESS research program, discussing a detector design study and promising results of 115In.

physics.ins-det