SearcharxivSearch

arXiv subjects

S. Rath

Publications and source records attributed to S. Rath.

6 recordsLinked to original sources

Effect of cobalt substitution on structural, impedance, ferroelectric and magnetic properties of multiferroic Bi_2Fe_4O_9 ceramics

Structural, impedance, ferroelectric and magnetic properties were examined in multiferroic Bi_{2}Fe_{4(1-x)}Co_{4x}O_{9} (0$\leq$x$\leq$0.02) ceramics synthesized via solid-state reaction method. X-ray diffraction analysis and Rietveld refinement showed secondary phase formation (for x$\geq$0.01) which was subsequently confirmed from room temperature Raman spectroscopy study. The frequency dependence of impedance and electric modulus of the material showed the presence of non-Debye type relaxation in all the samples. The values of the activation energies calculated from imaginary impedance and modulus lie in the range of 0.92-0.99 eV which confirmed that the oxygen vacancies play an important role in the conduction mechanism. Moreover, suitable amount of Co substitution significantly enhanced the remnant polarisation (2P_{r}) from 0.1193 $μ$C/cm^{2} (x=0) to 0.2776 $μ$C/cm^{2} (x=0.02). Besides, room temperature M-H measurement showed improved ferromagnetic hysteresis loop for all the modified samples. The remnant magnetization (M_{r}) and coercive field (H_{c}) increased from 0.0007 emu/gm and 42 Oe for x=0 to 0.1401 emu/gm and 296 Oe for x=0.02. The improved ferroelectricity was due to Co 3d-O 2p hybridization and enhanced magnetization originated from the partial substitution of Co^{3+} ions leading to breakdown of balance between the anti-parallel sub lattice magnetization of Fe^{3+} ions.

cond-mat.mtrl-sci

KOSMOS and COSMOS: New facility instruments for the NOAO 4-meter telescopes

We describe the design, construction and measured performance of the Kitt Peak Ohio State Multi-Object Spectrograph (KOSMOS) for the 4-m Mayall telescope and the Cerro Tololo Ohio State Multi-Object Spectrograph (COSMOS) for the 4-m Blanco telescope. These nearly identical imaging spectrographs are modified versions of the OSMOS instrument; they provide a pair of new, high-efficiency instruments to the NOAO user community. KOSMOS and COSMOS may be used for imaging, long-slit, and multi-slit spectroscopy over a 100 square arcminute field of view with a pixel scale of 0.29 arcseconds. Each contains two VPH grisms that provide R~2500 with a one arcsecond slit and their wavelengths of peak diffraction efficiency are approximately 510nm and 750nm. Both may also be used with either a thin, blue-optimized CCD from e2v or a thick, fully depleted, red-optimized CCD from LBNL. These instruments were developed in response to the ReSTAR process. KOSMOS was commissioned in 2013B and COSMOS was commissioned in 2014A.

astro-ph.IM

Detailed Report of the MuLan Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant

We present a detailed report of the method, setup, analysis and results of a precision measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured, nearly 100%-polarized, surface muon beam and a segmented, fast-timing, plastic scintillator array. The measurement employed two target arrangements; a magnetized ferromagnetic target with a ~4 kG internal magnetic field and a crystal quartz target in a 130 G external magnetic field. Approximately 1.6 x 10^{12} positrons were accumulated and together the data yield a muon lifetime of tau_{mu}(MuLan) = 2196980.3(2.2) ps (1.0 ppm), thirty times more precise than previous generations of lifetime experiments. The lifetime measurement yields the most accurate value of the Fermi constant G_F (MuLan) = 1.1663787(6) x 10^{-5} GeV^{-2} (0.5 ppm). It also enables new precision studies of weak interactions via lifetime measurements of muonic atoms.

hep-ex

Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant to Part-per-Million Precision

We report a measurement of the positive muon lifetime to a precision of 1.0 parts per million (ppm); it is the most precise particle lifetime ever measured. The experiment used a time-structured, low-energy muon beam and a segmented plastic scintillator array to record more than 2 x 10^{12} decays. Two different stopping target configurations were employed in independent data-taking periods. The combined results give tau_{mu^+}(MuLan) = 2196980.3(2.2) ps, more than 15 times as precise as any previous experiment. The muon lifetime gives the most precise value for the Fermi constant: G_F(MuLan) = 1.1663788 (7) x 10^-5 GeV^-2 (0.6 ppm). It is also used to extract the mu^-p singlet capture rate, which determines the proton's weak induced pseudoscalar coupling g_P.

hep-ex

Improved Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant

The mean life of the positive muon has been measured to a precision of 11 ppm using a low-energy, pulsed muon beam stopped in a ferromagnetic target, which was surrounded by a scintillator detector array. The result, tau_mu = 2.197013(24) us, is in excellent agreement with the previous world average. The new world average tau_mu = 2.197019(21) us determines the Fermi constant G_F = 1.166371(6) x 10^-5 GeV^-2 (5 ppm). Additionally, the precision measurement of the positive muon lifetime is needed to determine the nucleon pseudoscalar coupling g_P.

hep-ex

Data acquisition system for the MuLan muon lifetime experiment

We describe the data acquisition system for the MuLan muon lifetime experiment at Paul Scherrer Institute. The system was designed to record muon decays at rates up to 1 MHz and acquire data at rates up to 60 MB/sec. The system employed a parallel network of dual-processor machines and repeating acquisition cycles of deadtime-free time segments in order to reach the design goals. The system incorporated a versatile scheme for control and diagnostics and a custom web interface for monitoring experimental conditions.

nucl-ex