SearcharxivSearch

arXiv subjects

S. Rescia

Publications and source records attributed to S. Rescia.

9 recordsLinked to original sources

Quality control and quality assurance evaluation of ALFE2, a large-dynamic-range front-end ASIC de-veloped for the ATLAS Liquid Argon Calorimeter high-luminosity LHC upgrade

ALFE2 is a front-end ASIC developed for the ATLAS Liquid Argon (LAr) Calorimeter upgrade during the High-Luminosity Large Hadron Collider (HL-LHC) phase. ALFE2 comprises four preamplifier/shaper channels, each providing two distinct gain outputs to cover a 16-bit dynamic range. A robotic system has been developed for the automatic quality control test of ALFE2, and over 10% of the 80,000 chips have been evaluated by September 2025. The evaluation has allowed us to establish grading criteria. Using these criteria, a yield of over 85% was achieved in the evaluation tests, and these criteria are now being applied to the ongoing full-production QC. Irradiation tests were also performed for the quality assurance of ALFE2. No significant performance degradation was observed during the total-ionizing-dose (TID) test. Based on the single-event effect (SEE) test results, an error rate of fewer than 4.6 single-event upsets (SEUs) per day is extrapolated for the entire ATLAS LAr Calorimeter during HL-LHC operation.

physics.ins-det

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This paper addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

physics.ins-det

Ultra-pure Nickel for Structural Components of Low-Radioactivity Instruments

The next generation of rare-event search experiments in nuclear and particle physics demand structural materials combining exceptional mechanical strength with ultra-low levels of radioactive contamination. This study evaluates chemical vapor deposition (CVD) nickel as a candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates underwent tensile testing before and after welding alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, welding and heat treatment were found to reduce the tensile strength to levels comparable to standard Ni, with observed porosity in the welds likely contributing to this reduction. Material assay via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution produced measured bulk concentration of 232-Th, 238-U, and nat-K at the levels of ~70 ppq, <100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 micrometer beneath the surface, likely associated with the aluminum growth substrate. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in welding and surface cleaning techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.

nucl-ex

Sensitivity of nEXO to $^{136}$Xe Charged-Current Interactions: Background-free Searches for Solar Neutrinos and Fermionic Dark Matter

We study the sensitivity of nEXO to solar neutrino charged-current interactions, $\nu_e + ^{136}$Xe$\rightarrow ^{136}$Cs$^* + e^-$, as well as analogous interactions predicted by models of fermionic dark matter. Due to the recently observed low-lying isomeric states of $^{136}$Cs, these interactions will create a time-delayed coincident signal observable in the scintillation channel. Here we develop a detailed Monte Carlo of scintillation emission, propagation, and detection in the nEXO detector to model these signals under different assumptions about the timing resolution of the photosensor readout. We show this correlated signal can be used to achieve background discrimination on the order of $10^{-9}$, enabling nEXO to make background-free measurements of solar neutrinos above the reaction threshold of 0.668 MeV. We project that nEXO could measure the flux of CNO solar neutrinos with a statistical uncertainty of 25%, thus contributing a novel and competitive measurement towards addressing the solar metallicity problem. Additionally, nEXO could measure the mean energy of the $^7$Be neutrinos with a precision of $\sigma \leq 1.5$ keV and could determine the survival probability of $^{7}$Be and $pep$ solar $\nu_e$ with precision comparable to state-of-the-art. These quantities are sensitive to the Sun's core temperature and to non-standard neutrino interactions, respectively. Furthermore, the strong background suppression would allow nEXO to search for for charged-current interactions of fermionic dark matter in the mass range $m_\chi$ = $0.668$-$7$ MeV with a sensitivity up to three orders of magnitude better than current limits.

nucl-ex

Characterization of the ATLAS Liquid Argon Front-End ASIC ALFE2 for the HL-LHC upgrade

ALFE2 is an ATLAS Liquid Argon Calorimeter (LAr) Front-End ASIC designed for the HL-LHC upgrade. ALFE2 comprises four channels of pre-amplifiers and CR-(RC)2 shapers with adjustable input impedance. ALFE2 features two separate gain outputs to provide 16-bit dynamic-range coverage and an optimum resolution. ALFE2 is characterized using a Front-End Test Board (FETB) based on a Zynq UltraScale+ MPSoC and two octal-channel 16-bit high-speed ADCs. The test results indicate that ALFE2 fulfills or greatly exceeds all specifications on gain, noise, linearity, uniformity, and radiation tolerance.

physics.ins-det

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.

physics.ins-det

A Storage Ring Experiment to Detect a Proton Electric Dipole Moment

A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}e\cdot$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the scale of 3000~TeV.

physics.acc-ph

The FP420 R&D Project: Higgs and New Physics with forward protons at the LHC

We present the FP420 R&D project, which has been studying the key aspects of the development and installation of a silicon tracker and fast-timing detectors in the LHC tunnel at 420 m from the interaction points of the ATLAS and CMS experiments. These detectors would measure precisely very forward protons in conjunction with the corresponding central detectors as a means to study Standard Model (SM) physics, and to search for and characterise New Physics signals. This report includes a detailed description of the physics case for the detector and, in particular, for the measurement of Central Exclusive Production, pp --> p + phi + p, in which the outgoing protons remain intact and the central system phi may be a single particle such as a SM or MSSM Higgs boson. Other physics topics discussed are gamma-gamma and gamma-p interactions, and diffractive processes. The report includes a detailed study of the trigger strategy, acceptance, reconstruction efficiencies, and expected yields for a particular p p --> p H p measurement with Higgs boson decay in the b-bbar mode. The document also describes the detector acceptance as given by the LHC beam optics between the interaction points and the FP420 location, the machine backgrounds, the new proposed connection cryostat and the moving ("Hamburg") beam-pipe at 420 m, and the radio-frequency impact of the design on the LHC. The last part of the document is devoted to a description of the 3D silicon sensors and associated tracking performances, the design of two fast-timing detectors capable of accurate vertex reconstruction for background rejection at high-luminosities, and the detector alignment and calibration strategy.

hep-ex

A New Method For A Sensitive Deuteron EDM Experiment

In this paper a new method is presented for particles in storage rings which could reach a statistical sensitivity of 10**(-27) e cm for the deuteron EDM. This implies an improvement of two orders of magnitude over the present best limits on the T-odd nuclear forces ksi parameter.

hep-ex