Searcharxiv⌕ Search

arXiv subjects

S. Ritt

Publications and source records attributed to S. Ritt.

30 records · Page 2Linked to original sources

A direct time measurements technique for the two-dimensional precision coordinate detectors based on thin-walled drift tubes

This article presents the results of a study of the longitudinal spatial resolution of 2 m long straw tubes by means of the direct timing method (DTM). The feasibility of achieving a coordinate resolution (r.m.s.) better than 2 cm over full length of the straw is demonstrated. The spatial resolution insignificantly changes when measured by detecting gammas from a Fe-55 gamma ray source or minimum ionizing particles from a Ru-106 source. The use of the same type of FEE for data taking both for measuring the drift time of ionization electrons and propagation of a signal along the anode wire allows one to construct a two-dimensional detector for precision coordinate measurements.

physics.ins-det↗

Development of a plasma panel radiation detector: recent progress and key issues

A radiation detector based on plasma display panel technology, which is the principal component of plasma television displays is presented. Plasma Panel Sensor (PPS) technology is a variant of micropattern gas radiation detectors. The PPS is conceived as an array of sealed plasma discharge gas cells which can be used for fast response (O(5ns) per pixel), high spatial resolution detection (pixel pitch can be less than 100 micrometer) of ionizing and minimum ionizing particles. The PPS is assembled from non-reactive, intrinsically radiation-hard materials: glass substrates, metal electrodes and inert gas mixtures. We report on the PPS development program, including simulations and design and the first laboratory studies which demonstrate the usage of plasma display panels in measurements of cosmic ray muons, as well as the expansion of experimental results on the detection of betas from radioactive sources.

physics.ins-det↗

New limit on the lepton-flavour violating decay mu -> e gamma

We present a new result based on an analysis of the data collected by the MEG detector at the Paul Scherrer Institut in 2009 and 2010, in search of the lepton flavour violating decay mu->e gamma. The likelihood analysis of the combined data sample, which corresponds to a total of 1.8 x 10**14 muon decays, gives a 90% C.L. upper limit of 2.4 x 10**-12 on the branching ratio of the mu->e gamma decay, constituting the most stringent limit on the existence of this decay to date.

hep-ex↗

A limit for the mu -> e gamma decay from the MEG experiment

A search for the decay mu -> e gamma, performed at PSI and based on data from the initial three months of operation of the MEG experiment, yields an upper limit on the branching ratio of BR(mu -> e gamma) < 2.8 x 10**-11 (90% C.L.). This corresponds to the measurement of positrons and photons from ~ 10**14 stopped mu-decays by means of a superconducting positron spectrometer and a 900 litre liquid xenon photon detector.

hep-ex↗

New Precise Measurement of the Pion Weak Form Factors in the Pi+ -> e+ nu gamma Decay

We have measured the $π^+\to {\rm e}^+νγ$ branching ratio over a wide region of phase space, based on a total of 65,460 events acquired using the PIBETA detector. Minimum-$χ^2$ fits to the measured $(E_{e^+},E_γ)$ energy distributions result in the weak form factor value of $F_A=0.0119(1)$ with a fixed value of $F_V=0.0259$. An unconstrained fit yields $F_V=0.0258(17)$ and $F_A=0.0117(17)$. In addition, we have measured $a=0.10(6)$ for the dependence of $F_V$ on $q^2$, the ${\rm e}^{+}ν$ pair invariant mass squared, parametrized as $F_V(q^2)=F_V(0)(1+a\cdot q^2)$. The branching ratio for the kinematic region $E_γ> 10 $MeV and $θ_{{\rm e^+}γ} > 40^\circ $ is measured to be $B^{\rm exp}=73.86(54) \times 10^{-8}$. Earlier deviations we reported in the high-$E_γ$/low-$E_{{\rm e}^+}$ kinematic region are resolved, and we find full compatibility with CVC and standard $V$$-$$A$ calculations without a tensor term. We also derive new values for the pion polarizability, $α_E = \rm 2.78(10) \times 10^{-4} fm^3$, and neutral pion lifetime, $τ_{π0} = (8.5 \pm 1.1) \times 10^{-17} $s.

hep-ex↗

Precise Measurement of the Pi+ -> Pi0 e+ nu Branching Ratio

Using a large acceptance calorimeter and a stopped pion beam we have made a precise measurement of the rare Pi+ -> Pi0 e+ Nu,(pi_beta) decay branching ratio. We have evaluated the branching ratio by normalizing the number of observed pi_beta decays to the number of observed Pi+ -> e+ Nu, (pi_{e2}) decays. We find the value of Gamma(Pi+ -> Pi0 e+ Nu)/Gamma(total) = [1.036 +/- 0.004(stat.) +/- 0.004(syst.) +/- 0.003(pi_{e2})] x 10^{-8}$, where the first uncertainty is statistical, the second systematic, and the third is the pi_{e2} branching ratio uncertainty. Our result agrees well with the Standard Model prediction.

hep-ex↗

Absorption of Scintillation Light in a 100 $\ell$ Liquid Xenon$γ$ Ray Detector and Expected Detector Performance

An 800L liquid xenon scintillation $γ$ ray detector is being developed for the MEG experiment which will search for $μ^+\to\mathrm{e}^+γ$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by impurities might possibly limit the performance of such a detector. We used a 100L prototype with an active volume of 372x372x496 mm$^3$ to study the scintillation light absorption. We have developed a method to evaluate the light absorption, separately from elastic scattering of light, by measuring cosmic rays and $α$ sources. By using a suitable purification technique, an absorption length longer than 100 cm has been achieved. The effects of the light absorption on the energy resolution are estimated by Monte Carlo simulation.

physics.ins-det↗

Precise Measurement of the Pion Axial Form Factor in the Pi+ -> e+ nu gamma Decay

We have studied radiative pion decays Pi+ -> e+ nu gamma in three broad kinematic regions using the PIBETA detector and a stopped pion beam. Based on Dalitz distributions of 42,209 events we have evaluated absolute Pi -> e nu gamma branching ratios in the three regions. Minimum chi^2 fits to the integral and differential (E(e+),E(gamma)) distributions result in the axial-to-vector weak form factor ratio of gamma = F_A/F_V = 0.443(15),or F_A = 0.0115(4) with F_V = 0.0259. However, deviations from Standard Model predictions in the high-E(gamma)/low-E(e+) kinematic region indicate the need for further theoretical and experimental work.

hep-ex↗

Design, Commissioning and Performance of the PIBETA Detector at PSI

We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an active segmented plastic target, a pair of low-mass cylindrical wire chambers and a 20-element cylindrical plastic scintillator hodoscope. The whole detector system is housed inside a temperature-controlled lead brick enclosure which in turn is lined with cosmic muon plastic veto counters. Commissioning and calibration data were taken during two three-month beam periods in 1999/2000 with pi+ stopping rates between 1.3*E3 pi+/s and 1.3*E6 pi+/s. We examine the timing, energy and angular detector resolution for photons, positrons and protons in the energy range of 5-150 MeV, as well as the response of the detector to cosmic muons. We illustrate the detector signatures for the assorted rare pion and muon decays and their associated backgrounds.

hep-ex↗

ADC common noise correction and zero suppression in the PIBETA detector

We describe a simple procedure for reducing ADC common noise in modular detectors that does not require additional hardware. A method using detector noise groups should work well for modular particle detectors such as segmented electromagnetic calorimeters, plastic scintillator hodoscopes, cathode strip wire chambers, segmented active targets, and the like. We demonstrate a ``second pedestal noise correction'' method by comparing representative ADC pedestal spectra for various elements of the PIBETA detector before and after the applied correction.

hep-ex↗

Light response of pure CsI calorimeter crystals painted with wavelength-shifting lacquer

We have measured scintillation properties of pure CsI crystals used in the shower calorimeter built for a precise determination of the pi+ -> pi0 e+ nu decay rate at the Paul Scherrer Institute (PSI). All 240 individual crystals painted with a special wavelength-shifting solution were examined in a custom-build detection apparatus (RASTA=radioactive source tomography apparatus) that uses a 137Cs radioactive gamma source, cosmic muons and a light emitting diode as complementary probes of the scintillator light response. We have extracted the total light output, axial light collection nonuniformities and timing responses of the individual CsI crystals. These results predict improved performance of the 3 pi sr PIBETA calorimeter due to the painted lateral surfaces of 240 CsI crystals. The wavelength-shifting paint treatment did not affect appreciably the total light output and timing resolution of our crystal sample. The predicted energy resolution for positrons and photons in the energy range of 10-100 MeV was nevertheless improved due to the more favorable axial light collection probability variation. We have compared simulated calorimeter ADC spectra due to 70 MeV positrons and photons with a Monte Carlo calculation of an ideal detector light response.

hep-ex↗

Cosmic muon tomography of pure cesium iodide calorimeter crystals

Scintillation properties of pure CsI crystals used in the shower calorimeter being built for precise determination of the pi+ -> pi0 e+ nu decay rate are reported. Seventy-four individual crystals, polished and wrapped in Teflon foil, were examined in a multiwire drift chamber system specially designed for transmission cosmic muon tomography. Critical elements of the apparatus and reconstruction algorithms enabling measurement of spatial detector optical nonuniformities are described. Results are compared with a Monte Carlo simulation of the light response of an ideal detector. The deduced optical nonuniformity contributions to the FWHM energy resolution of the PIBETA CsI calorimeter for the pi+ -> e+ nu 69.8 MeV positrons and the monoenergetic 70.8 MeV photons were 2.7% and 3.7%, respectively. The upper limit of optical nonuniformity correction to the 69.8 MeV positron low-energy tail between 5 MeV and 55 MeV was +0.2%, as opposed to the +0.3% tail contribution for the photon of the equivalent total energy. Imposing the 5 MeV calorimeter veto cut to suppress the electromagnetic losses, GEANT-evaluated positron and photon lineshape tail fractions summed over all above-threshold ADCs were found to be 2.36+-0.05(stat)+-0.20(sys)% and 4.68+-0.07(stat)+-0.20(sys)%, respectively.

hep-ex↗