SearcharxivSearch

arXiv subjects

S. Ronayette

Publications and source records attributed to S. Ronayette.

8 recordsLinked to original sources

COLIBRI (SVOM/FM-GFT): Instrumentation and Performances on the SVOM Alerts

COLIBRI, the French Mexican Ground Followup Telescope (FM GFT) for SVOM, is a 1.3 meter rapid response optical facility specifically developed for prompt, multiband observations of GRB afterglows and for delivering subarcsecond localisations of optical counterparts for detailed followup studies. The telescope operates through a fully automated system that manages the entire workflow, from alert reception to counterpart identification. Commissioning results confirm that the telescope meets design specifications, and this paper presents a comprehensive performance assessment of the capabilities.

astro-ph.IM

Very High Precision Astrometry for Exoplanets and Dark Matter with the Habitable Worlds Observatory

Astrometry, one of the oldest branches of astronomy, has been revolutionized by missions like Hipparcos and especially Gaia, which mapped billions of stars with extraordinary precision. However, challenges such as detecting Earth-like exoplanets in nearby habitable zones and probing the influence of dark matter in galactic environments require sub-microarcsecond accuracy. With a 6--8 meter large-aperture telescope operating across at visible wavelengths, the Habitable Worlds Observatory by NASA can combine astrometry and direct imaging to detect rocky exoplanets within 10 parsecs and study their atmospheres. We consider here the scientific requirements and present a concept for a dedicated astrometric instrument on HWO. It is capable to produce diffraction-limited images of large fields, achieving a point-spread function (PSF) precision of 20 milliarcseconds. Equipped with a detector calibration system, HWO can perform high precision astrometry, and, detect and measure the orbit of Earth-mass planets in the habitable zone of Nearby Solar-type stars. HWO can dramatically improve current constraints on the self- interaction cross-section of heavy dark matter particles (WIMPs) and on the masses of ultra-high dark matter particles, through the study of stellar motions in galactic environments. The visible channel of the instrument features a large CMOS-based focal plane with stitched pixel arrays, enabling a large field of view. The ``Detector Calibration Unit'' system uses interferometric laser fringes to calibrate pixel positions. Using differential astrometry and pointed observations with a stable telescope design enables extended integration times, enhancing sensitivity to sub-microarcsecond precision for detecting exoplanets and studying dark matter through stellar motion.

astro-ph.IM

Testing the 10 spectrograph units for DESI: approach and results

The recently commissioned Dark Energy Spectroscopic Instrument (DESI) will measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 sqdeg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope delivers light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. A consortium of Aix-Marseille University (AMU) and CNRS laboratories (LAM, OHP and CPPM) together with LPNHE (CNRS, IN2P3, Sorbonne Université and Université de Paris) and the WINLIGHT Systems company based in Pertuis (France), were in charge of integrating and validating the performance requirements of the ten full spectrographs, equipped with their cryostats, shutters and other mechanisms. We present a summary of our activity which allowed an efficient validation of the systems in a short-time schedule. We detail the main results. We emphasize the benefits of our approach and also its limitations.

astro-ph.IM

The Mid-Infrared Instrument for the James Webb Space Telescope: IV. The Low Resolution Spectrometer

The Low Resolution Spectrometer of the MIRI, which forms part of the imager module, will provide R~100 long-slit and slitless spectroscopy from 5 to 12 micron. The design is optimised for observations of compact sources, such as exoplanet host stars. We provide here an overview of the design of the LRS, and its performance as measured during extensive test campaigns, examining in particular the delivered image quality, dispersion, and resolving power, as well as spectrophotometric performance, flatfield accuracy and the effects of fringing. We describe the operational concept of the slitless mode, which is optimally suited to transit spectroscopy of exoplanet atmospheres. The LRS mode of the MIRI was found to perform consistently with its requirements and goals.

astro-ph.IM

The Mid-Infrared Instrument for the James Webb Space Telescope, III: MIRIM, The MIRI Imager

In this article, we describe the MIRI Imager module (MIRIM), which provides broad-band imaging in the 5 - 27 microns wavelength range for the James Webb Space Telescope. The imager has a 0"11 pixel scale and a total unobstructed view of 74"x113". The remainder of its nominal 113"x113" field is occupied by the coronagraphs and the low resolution spectrometer. We present the instrument optical and mechanical design. We show that the test data, as measured during the test campaigns undertaken at CEA-Saclay, at the Rutherford Appleton Laboratory, and at the NASA Goddard Space Flight Center, indicate that the instrument complies with its design requirements and goals. We also discuss the operational requirements (multiple dithers and exposures) needed for optimal scientific utilization of the MIRIM.

astro-ph.IM

The Mid-Infrared Instrument for the James Webb Space Telescope, V: Predicted Performance of the MIRI Coronagraphs

The imaging channel on the Mid-Infrared Instrument (MIRI) is equipped with four coronagraphs that provide high contrast imaging capabilities for studying faint point sources and extended emission that would otherwise be overwhelmed by a bright point-source in its vicinity. Such bright sources might include stars that are orbited by exoplanets and circumstellar material, mass-loss envelopes around post-main-sequence stars, the near-nuclear environments in active galaxies, and the host galaxies of distant quasars. This paper describes the coronagraphic observing modes of MIRI, as well as performance estimates based on measurements of the MIRI flight model during cryo-vacuum testing. A brief outline of coronagraphic operations is also provided. Finally, simulated MIRI coronagraphic observations of a few astronomical targets are presented for illustration.

astro-ph.IM

Optical performance of the JWST MIRI flight model: characterization of the point spread function at high-resolution

The Mid Infra Red Instrument (MIRI) is one of the four instruments onboard the James Webb Space Telescope (JWST), providing imaging, coronagraphy and spectroscopy over the 5-28 microns band. To verify the optical performance of the instrument, extensive tests were performed at CEA on the flight model (FM) of the Mid-InfraRed IMager (MIRIM) at cryogenic temperatures and in the infrared. This paper reports on the point spread function (PSF) measurements at 5.6 microns, the shortest operating wavelength for imaging. At 5.6 microns the PSF is not Nyquist-sampled, so we use am original technique that combines a microscanning measurement strategy with a deconvolution algorithm to obtain an over-resolved MIRIM PSF. The microscanning consists in a sub-pixel scan of a point source on the focal plane. A data inversion method is used to reconstruct PSF images that are over-resolved by a factor of 7 compared to the native resolution of MIRI. We show that the FWHM of the high-resolution PSFs were 5-10% wider than that obtained with Zemax simulations. The main cause was identified as an out-of-specification tilt of the M4 mirror. After correction, two additional test campaigns were carried out, and we show that the shape of the PSF is conform to expectations. The FWHM of the PSFs are 0.18-0.20 arcsec, in agreement with simulations. 56.1-59.2% of the total encircled energy (normalized to a 5 arcsec radius) is contained within the first dark Airy ring, over the whole field of view. At longer wavelengths (7.7-25.5 microns), this percentage is 57-68%. MIRIM is thus compliant with the optical quality requirements. This characterization of the MIRIM PSF, as well as the deconvolution method presented here, are of particular importance, not only for the verification of the optical quality and the MIRI calibration, but also for scientific applications.

astro-ph.IM

In-flight calibration of the Herschel-SPIRE instrument

SPIRE, the Spectral and Photometric Imaging Receiver, is the Herschel Space Observatory's submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 μm, and an imaging Fourier transform spectrometer (FTS) covering 194-671 μm (447-1550 GHz). In this paper we describe the initial approach taken to the absolute calibration of the SPIRE instrument using a combination of the emission from the Herschel telescope itself and the modelled continuum emission from solar system objects and other astronomical targets. We present the photometric, spectroscopic and spatial accuracy that is obtainable in data processed through the "standard" pipelines. The overall photometric accuracy at this stage of the mission is estimated as 15% for the photometer and between 15 and 50% for the spectrometer. However, there remain issues with the photometric accuracy of the spectra of low flux sources in the longest wavelength part of the SPIRE spectrometer band. The spectrometer wavelength accuracy is determined to be better than 1/10th of the line FWHM. The astrometric accuracy in SPIRE maps is found to be 2 arcsec when the latest calibration data are used. The photometric calibration of the SPIRE instrument is currently determined by a combination of uncertainties in the model spectra of the astronomical standards and the data processing methods employed for map and spectrum calibration. Improvements in processing techniques and a better understanding of the instrument performance will lead to the final calibration accuracy of SPIRE being determined only by uncertainties in the models of astronomical standards.

astro-ph.IM