SearcharxivSearch

arXiv subjects

S. Rowe

Publications and source records attributed to S. Rowe.

4 recordsLinked to original sources

Data reduction pipeline for the SuMAC millimeter-wave spectrometer at the LMT

We present the data reduction and analysis pipeline for the SuperSpec-MUSCAT Collaboration (SuMAC) along with several key science data products. In Summer 2025, SuperSpec on-chip spectrometers operating from $190-300$ GHz at $R\sim200$ were deployed in the MUSCAT cryostat at the Large Millimeter Telescope, obtaining several days of on-sky data. Analysis of these data has been used to characterize noise performance and study spectra of various astrophysical sources, establishing the viability of deploying SuperSpec detectors in future instruments. These proceedings discuss the modular data reduction pipeline which uses timestreams of the kinetic inductance detectors (KIDs) and auxiliary instrument data to generate a variety of data products. We present an on-sky calibration method for converting the KID fractional frequency shift to on-sky brightness temperature. The mapmaking module generates 3D data cubes of extended sources, while the spectrum module produces a millimeter-wave spectrum of an object. The observations all incorporate measurements of the atmosphere to model and correct for absorption. We also discuss data processing choices including detector weighting, despiking, and notch filtering. Finally, we present preliminary data products including detection of carbon monoxide in NGC 253 and spectral maps of the central region of the Orion KL nebula.

astro-ph.IM

Pre-deployment Verification and Predicted Mapping Speed of MUSCAT

The Mexico-UK Submillimetre Camera for AsTronomy (MUSCAT) is a 1.1 mm receiver consisting of 1,500 lumped-element kinetic inductance detectors (LEKIDs) for the Large Millimeter Telescope (LMT; Volc\'an Sierra Negra in Puebla, M\'exico). MUSCAT utilises the maximum field of view of the LMT's upgraded 50-metre primary mirror and is the first M\'exico-UK collaboration to deploy a millimetre/sub-mm receiver on the Large Millimeter Telescope. Using a simplistic simulator, we estimate a predicted mapping speed for MUSCAT by combining the measured performance of MUSCAT with the observed sky conditions at the LMT. We compare this to a previously calculated bolometric-model mapping speed and find that our mapping speed is in good agreement when this is scaled by a previously reported empirical factor. Through this simulation we show that signal contamination due to sky fluctuations can be effectively removed through the use of principle component analysis. We also give an overview of the instrument design and explain how this design allows for MUSCAT to be upgraded and act as an on-sky demonstration testbed for novel technologies after the facility-class TolTEC receiver comes online.

astro-ph.IM

MUSCAT focal plane verification

The Mexico-UK Submillimetre Camera for Astronomy (MUSCAT) is the second-generation large-format continuum camera operating in the 1.1 mm band to be installed on the 50-m diameter Large Millimeter Telescope (LMT) in Mexico. The focal plane of the instrument is made up of 1458 horn coupled lumped-element kinetic inductance detectors (LEKID) divided equally into six channels deposited on three silicon wafers. Here we present the preliminary results of the complete characterisation in the laboratory of the MUSCAT focal plane. Through the instrument's readout system, we perform frequency sweeps of the array to identify the resonance frequencies, and continuous timestream acquisitions to measure and characterise the intrinsic noise and 1/f knee of the detectors. Subsequently, with a re-imaging lens and a black body point source, the beams of every detector are mapped, obtaining a mean FWHM size of $\sim$3.27 mm, close to the expected 3.1 mm. Then, by varying the intensity of a beam filling black body source, we measure the responsivity and noise power spectral density (PSD) for each detector under an optical load of 300 K, obtaining the noise equivalent power (NEP), with which we verify that the majority of the detectors are photon noise limited. Finally, using a Fourier Transform Spectrometer (FTS), we measure the spectral response of the instrument, which indicate a bandwidth of 1.0--1.2 mm centred on 1.1 mm, as expected.

astro-ph.IM

Curing and post-curing luminescence in an epoxy resin

A spontaneous luminescence is reported when epoxy resin samples are heated in air. This phenomenon is very sensitive to the nature of the atmosphere. The same treatment in nitrogen leads to an extinction of the luminescence. The emission process is restored when samples are kept for a sufficient time in air. In order to better understand this phenomenon, we have investigated the luminescence of the elementary constituents of the epoxy (resin and hardener) when heated in air and nitrogen, as well as during resin curing in the same atmospheres. It appears that the emission process is linked with the presence of oxygen. Although the kinetics of the luminescence can differ depending on the nature of the sample (cured resin, resin during curing, liquid components), the emission spectra are the same during resin curing and upon heating of the cured resin and hardener. The emission spectrum of the base resin is different. It is concluded that the light results from a chemiluminescence process during oxidation.

cond-mat.mtrl-sci