Searcharxiv⌕ Search

arXiv subjects

S. Sánchez Majos

Publications and source records attributed to S. Sánchez Majos.

22 records · Page 2Linked to original sources

In-beam tests of scintillating fibre detectors at MAMI and at GSI

The performance of scintillating fibre detectors was studied with electrons at the spectrometer facility of the Mainz microtron MAMI, as well as in a C-12 beam of 2 AGeV energy and in a beam of different particle species at GSI. Multi-anode photomultipliers were used to read out one or more bundles of 128 fibres each in different geometries. For electrons a time resolution of FWHM = 1 ns was measured in a single detector plane with a detection efficiency epsilon > 99%. A time resolution of 310 ps (FWHM) between two planes of fibres was achieved for carbon ions, leading to a FWHM = 220 ps for a single detector. The hit position residual was measured with a width of FWHM = 0.27 mm. The variation in the measured energy deposition was Delta E/E= 15-20% (FWHM) for carbon ions. In addition, the energy response to p/pi/d particles was studied. Based on the good detector performance fibre hodoscopes will be constructed for the KAOS/A1 spectrometer at MAMI and for the HypHI experiment at GSI.

nucl-ex↗

Recoil polarization and beam-recoil double polarization measurement of ηelectroproduction on the proton in the region of the S_{11}(1535) resonance

The beam-recoil double polarization P_{x'}^h and P_{z'}^h and the recoil polarization P_{y'} were measured for the first time for the p(\vec{e},e'\vec{p})ηreaction at a four-momentum transfer of Q^2=0.1 GeV^2/c^2 and a center of mass production angle of θ= 120^\circ at MAMI C. With a center of mass energy range of 1500 MeV < W < 1550 MeV the region of the S_{11}(1535) and D_{13}(1520) resonance was covered. The results are discussed in the framework of a phenomenological isobar model (Eta-MAID). While P_{x'}^h and P_{z'}^h are in good agreement with the model, P_{y'} shows a significant deviation, consistent with existing photoproduction data on the polarized-target asymmetry.

nucl-ex↗

Measurement of Propagation Time Dispersion in a Scintillator

One contribution to the time resolution of a scintillation detector is the signal time spread due to path length variations of the detected photons from a point source. In an experimental study a rectangular scintillator was excited by means of a fast pulsed ultraviolet laser at different positions along its longitudinal axis. Timing measurements with a photomultiplier tube in a detection plane displaced from the scintillator end face showed a correlation between signal time and tube position indicating only a small distortion of photon angles during transmission. The data is in good agreement with a Monte Carlo simulation used to compute the average photon angle with respect to the detection plane and the average propagation time. Limitations on timing performance that arise from propagation time dispersion are expected for long and thin scintillators used in future particle identification systems.

nucl-ex↗

New detectors for the kaon and hypernuclear experiments with KaoS at MAMI and with PANDA at GSI

The KaoS spectrometer at the Mainz Microtron MAMI, Germany, is perceived as the ideal candidate for a dedicated spectrometer in kaon and hypernuclei electroproduction. KaoS will be equipped with new read-out electronics, a completely new focal plane detector package consisting of scintillating fibres, and a new trigger system. First prototypes of the fibre detectors and the associated new front-end electronics are shown in this contribution. The Mainz hypernuclei research program will complement the hypernuclear experiments at the planned FAIR facility at GSI, Germany. At the proposed antiproton storage ring the spectroscopy of double Lambda hypernuclei is one of the four main topics which will be addressed by the PANDA Collaboration. The experiments require the operation of high purity germanium (HPGe) detectors in high magnetic fields (B= 1T) in the presence of a large hadronic background. The performance of high resolution Ge detectors in such an environment has been investigated.

nucl-ex↗