SearcharxivSearch

arXiv subjects

S. S. Stepanyan

Publications and source records attributed to S. S. Stepanyan.

4 recordsLinked to original sources

How different is the core of $^{25}$F from $^{24}$O$_{g.s.}$?

The neutron-shell structure of $^{25}$F was studied using quasi-free (p,2p) knockout reaction at 270A MeV in inverse kinematics. The sum of spectroscopic factors of $π$0d$_{5/2}$ orbital is found to be $1.0 \pm 0.3$. However, the spectroscopic factor for the ground-state to ground-state transition ($^{25}$F, $^{24}$O$_{g.s.}$) is only $0.36\pm 0.13$, and $^{24}$O excited states are produced from the 0d$_{5/2}$ proton knockout. The result shows that the $^{24}$O core of $^{25}$F nucleus significantly differs from a free $^{24}$O nucleus, and the core consists of 35% $^{24}$O$_{g.s}$. and 65% excited $^{24}$O.

nucl-ex

Comment on the narrow structure reported by Amaryan et al

The CLAS Collaboration provides a comment on the physics interpretation of the results presented in a paper published by M. Amaryan et al. regarding the possible observation of a narrow structure in the mass spectrum of a photoproduction experiment.

hep-ex

Time and Amplitude of Afterpulse Measured with a Large Size Photomultiplier Tube

We have studied the afterpulse of a hemispherical photomultiplier tube for an upcoming reactor neutrino experiment. The timing, the amplitude, and the rate of the afterpulse for a 10 inch photomultiplier tube were measured with a 400 MHz FADC up to 16 \ms time window after the initial signal generated by an LED light pulse. The time and amplitude correlation of the afterpulse shows several distinctive groups. We describe the dependencies of the afterpulse on the applied high voltage and the amplitude of the main light pulse. The present data could shed light upon the general mechanism of the afterpulse.

physics.ins-det

Time resolution of Burle 85001 micro-channel plate photo-multipliers in comparison with Hamamatsu R2083

The CLAS detector will require improvements in its particle identification system to take advantage of the higher energies provided by the Jefferson Laboratory accelerator upgrade to 12 GeV. To this end, we have studied the timing characteristics of the micro-channel plate photo-multiplier 85001 from Burle, which can be operated in a high magnetic field environment. For reference and comparison, measurements were also made using the standard PMT R2083 from Hamamatsu using two timing methods. The cosmic ray method, which utilizes three identical scintillating counters 2cmx3cmx50cm with PMs at the ends, yields 59.1(0.7)ps. The location method of particles from radiative source with known coordiantes has been used to compare timing resolutions of R2083 and Burle-85001.This ``coordinate method'' requires only one counter instrumented with two PMs and it yields 59.5(0.7)ps. For the micro-channel plate photomultiplier from Burle with an external amplification of 10 to the signals, the coordinate method yields 130(4)ps. This method also makes it possible to estimate the number of primary photo-electrons.

nucl-ex