Searcharxiv⌕ Search

arXiv subjects

S. Schönert

Publications and source records attributed to S. Schönert.

142 records · Page 8Linked to original sources

Radiopurity of CaWO$_4$ Crystals for Direct Dark Matter Search with CRESST and EURECA

The direct dark matter search experiment CRESST uses scintillating CaWO$_4$ single crystals as targets for possible WIMP scatterings. An intrinsic radioactive contamination of the crystals as low as possible is crucial for the sensitivity of the detectors. In the past CaWO$_4$ crystals operated in CRESST were produced by institutes in Russia and the Ukraine. Since 2011 CaWO$_4$ crystals have also been grown at the crystal laboratory of the Technische Universität München (TUM) to better meet the requirements of CRESST and of the future tonne-scale multi-material experiment EURECA. The radiopurity of the raw materials and of first TUM-grown crystals was measured by ultra-low background $γ$-spectrometry. Two TUM-grown crystals were also operated as low-temperature detectors at a test setup in the Gran Sasso underground laboratory. These measurements were used to determine the crystals' intrinsic $α$-activities which were compared to those of crystals produced at other institutes. The total $α$-activities of TUM-grown crystals as low as 1.23 $\pm$ 0.06 mBq/kg were found to be significantly smaller than the activities of crystals grown at other institutes typically ranging between ~15 mBq/kg and ~35 mBq/kg.

astro-ph.IM↗

Results on neutrinoless double beta decay of 76Ge from GERDA Phase I

Neutrinoless double beta decay is a process that violates lepton number conservation. It is predicted to occur in extensions of the Standard Model of particle physics. This Letter reports the results from Phase I of the GERmanium Detector Array (GERDA) experiment at the Gran Sasso Laboratory (Italy) searching for neutrinoless double beta decay of the isotope 76Ge. Data considered in the present analysis have been collected between November 2011 and May 2013 with a total exposure of 21.6 kgyr. A blind analysis is performed. The background index is about 1.10^{-2} cts/(keV kg yr) after pulse shape discrimination. No signal is observed and a lower limit is derived for the half-life of neutrinoless double beta decay of 76Ge, T_1/2 > 2.1 10^{25} yr (90% C.L.). The combination with the results from the previous experiments with 76Ge yields T_1/2 > 3.0 10^{25} yr (90% C.L.).

nucl-ex↗

Pulse shape discrimination for GERDA Phase I data

The GERDA experiment located at the LNGS searches for neutrinoless double beta (0νββ) decay of ^{76}Ge using germanium diodes as source and detector. In Phase I of the experiment eight semi-coaxial and five BEGe type detectors have been deployed. The latter type is used in this field of research for the first time. All detectors are made from material with enriched ^{76}Ge fraction. The experimental sensitivity can be improved by analyzing the pulse shape of the detector signals with the aim to reject background events. This paper documents the algorithms developed before the data of Phase I were unblinded. The double escape peak (DEP) and Compton edge events of 2.615 MeV γ rays from ^{208}Tl decays as well as 2νββ decays of ^{76}Ge are used as proxies for 0νββ decay. For BEGe detectors the chosen selection is based on a single pulse shape parameter. It accepts 0.92$\pm$0.02 of signal-like events while about 80% of the background events at Q_{ββ}=2039 keV are rejected. For semi-coaxial detectors three analyses are developed. The one based on an artificial neural network is used for the search of 0νββ decay. It retains 90% of DEP events and rejects about half of the events around Q_{ββ}. The 2νββ events have an efficiency of 0.85\pm0.02 and the one for 0νββ decays is estimated to be 0.90^{+0.05}_{-0.09}. A second analysis uses a likelihood approach trained on Compton edge events. The third approach uses two pulse shape parameters. The latter two methods confirm the classification of the neural network since about 90% of the data events rejected by the neural network are also removed by both of them. In general, the selection efficiency extracted from DEP events agrees well with those determined from Compton edge events or from 2νββ decays.

physics.ins-det↗

Lifetime measurements of 214Po and 212Po with the CTF liquid scintillator detector at LNGS

We have studied the alpha decays of 214Po into 210Pb and of 212Po into 208Pb tagged by the coincidence with the preceding beta decays from 214Bi and 212Bi, respectively. The employed 222Rn, 232Th, and 220Rn sources were sealed inside quartz vials and inserted in the Counting Test Facility at the underground Gran Sasso National Laboratory in Italy. We find that the mean lifetime of 214Po is (236.00 +- 0.42(stat) +- 0.15(syst)) μs and that of 212Po is (425.1 +- 0.9(stat) +- 1.2(syst)) ns. Our results, obtained from data with signal-to-background ratio larger than 1000, reduce the overall uncertainties and are compatible with previous measurements.

nucl-ex↗

Cosmogenic Backgrounds in Borexino at 3800 m water-equivalent depth

The solar neutrino experiment Borexino, which is located in the Gran Sasso underground laboratories, is in a unique position to study muon-induced backgrounds in an organic liquid scintillator. In this study, a large sample of cosmic muons is identified and tracked by a muon veto detector external to the liquid scintillator, and by the specific light patterns observed when muons cross the scintillator volume. The yield of muon-induced neutrons is found to be Yn =(3.10+-0.11)10-4 n/(μ (g/cm2)). The distance profile between the parent muon track and the neutron capture point has the average value λ = (81.5 +- 2.7)cm. Additionally the yields of a number of cosmogenic radioisotopes are measured for 12N, 12B, 8He, 9C, 9Li, 8B, 6He, 8Li, 11Be, 10C and 11C. All results are compared with Monte Carlo simulation predictions using the Fluka and Geant4 packages. General agreement between data and simulation is observed for the cosmogenic production yields with a few exceptions, the most prominent case being 11C yield for which both codes return about 50% lower values. The predicted μ-n distance profile and the neutron multiplicity distribution are found to be overall consistent with data.

physics.ins-det↗

Isotopically modified Ge detectors for {\sc Gerda}: from production to operation

The \textsc{Gerda} experiment searches for the neutrinoless double beta ($0νβ$beta$) decay of $^{76}$Ge using high-purity germanium detectors made of material enriched in $^{76}$Ge. For Phase II of the experiment a sensitivity for the half life $T_{1/2}^{0ν}\,\,\sim2\cdot10^{26}$ yr is envisioned. Modified Broad Energy Germanium detectors (BEGe) with thick n$^+$ electrodes provide the capability to efficiently identify and reject background events, while keeping a large acceptance for the $0νβ$beta$-decay signal through novel pulse-shape discrimination (PSD) techniques. The viability of producing thick-window BEGe-type detectors for the \textsc{Gerda} experiment is demonstrated by testing all the production steps from the procurement of isotopically modified germanium up to working BEGe detectors. Comprehensive testing of the spectroscopic as well as PSD performance of the \textsc{Gerda} Phase II prototype BEGe detectors proved that the properties of these detectors are identical to those produced previously from natural germanium material following the standard production line of the manufacturer. Furthermore, the production of BEGe detectors from a limited amount of isotopically modified germanium served to optimize the production, in order to maximize the overall detector mass yield. The results of this test campaign provided direct input for the subsequent production of the enriched germanium detectors.

physics.ins-det↗

Cosmic-muon flux and annual modulation in Borexino at 3800 m water-equivalent depth

We have measured the muon flux at the underground Gran Sasso National Laboratory (3800 m w.e.) to be (3.41 \pm 0.01) \times 10-4m-2s-1 using four years of Borexino data. A modulation of this signal is observed with a period of (366\pm3) days and a relative amplitude of (1.29 \pm 0.07)%. The measured phase is (179 \pm 6) days, corresponding to a maximum on the 28th of June. Using the most complete atmospheric data models available, muon rate fluctuations are shown to be positively correlated with atmospheric temperature, with an effective coefficient αT = 0.93 \pm 0.04. This result represents the most precise study of the muon flux modulation for this site and is in good agreement with expectations.

hep-ex↗

Large scale Gd-beta-diketonate based organic liquid scintillator production for antineutrino detection

Over the course of several decades, organic liquid scintillators have formed the basis for successful neutrino detectors. Gadolinium-loaded liquid scintillators provide efficient background suppression for electron antineutrino detection at nuclear reactor plants. In the Double Chooz reactor antineutrino experiment, a newly developed beta-diketonate gadolinium-loaded scintillator is utilized for the first time. Its large scale production and characterization are described. A new, light yield matched metal-free companion scintillator is presented. Both organic liquids comprise the target and "Gamma Catcher" of the Double Chooz detectors.

physics.ins-det↗

Qualification Tests of 474 Photomultiplier Tubes for the Inner Detector of the Double Chooz Experiment

The hemispherical 10" photomultiplier tube (PMT) R7081 from Hamamatsu Photonics K.K. (HPK) is used in various experiments in particle and astroparticle physics. We describe the test and calibration of 474 PMTs for the reactor antineutrino experiment Double Chooz. The unique test setup at Max-Planck-Institut für Kernphysik Heidelberg (MPIK) allows one to calibrate 30 PMTs simultaneously and to characterize the single photo electron response, transit time spread, linear behaviour and saturation effects, photon detection efficiency and high voltage calibration.

physics.ins-det↗

Muon and Cosmogenic Neutron Detection in Borexino

Borexino, a liquid scintillator detector at LNGS, is designed for the detection of neutrinos and antineutrinos from the Sun, supernovae, nuclear reactors, and the Earth. The feeble nature of these signals requires a strong suppression of backgrounds below a few MeV. Very low intrinsic radiogenic contamination of all detector components needs to be accompanied by the efficient identification of muons and of muon-induced backgrounds. Muons produce unstable nuclei by spallation processes along their trajectory through the detector whose decays can mimic the expected signals; for isotopes with half-lives longer than a few seconds, the dead time induced by a muon-related veto becomes unacceptably long, unless its application can be restricted to a sub-volume along the muon track. Consequently, not only the identification of muons with very high efficiency but also a precise reconstruction of their tracks is of primary importance for the physics program of the experiment. The Borexino inner detector is surrounded by an outer water-Cherenkov detector that plays a fundamental role in accomplishing this task. The detector design principles and their implementation are described. The strategies adopted to identify muons are reviewed and their efficiency is evaluated. The overall muon veto efficiency is found to be 99.992% or better. Ad-hoc track reconstruction algorithms developed are presented. Their performance is tested against muon events of known direction such as those from the CNGS neutrino beam, test tracks available from a dedicated External Muon Tracker and cosmic muons whose angular distribution reflects the local overburden profile. The achieved angular resolution is 3-5 deg and the lateral resolution is 35-50 cm, depending on the impact parameter of the crossing muon. The methods implemented to efficiently tag cosmogenic neutrons are also presented.

physics.ins-det↗

Signal modeling of high-purity Ge detectors with a small read-out electrode and application to neutrinoless double beta decay search in Ge-76

The GERDA experiment searches for the neutrinoless double beta decay of Ge-76 using high-purity germanium detectors enriched in Ge-76. The analysis of the signal time structure provides a powerful tool to identify neutrinoless double beta decay events and to discriminate them from gamma-ray induced backgrounds. Enhanced pulse shape discrimination capabilities of "Broad Energy Germanium" detectors with a small read-out electrode have been recently reported. This paper describes the full simulation of the response of such a detector, including the Monte Carlo modeling of radiation interaction and subsequent signal shape calculation. A pulse shape discrimination method based on the ratio between the maximum current signal amplitude and the event energy applied to the simulated data shows quantitative agreement with the experimental data acquired with calibration sources. The simulation has been used to study the survival probabilities of the decays which occur inside the detector volume and are difficult to assess experimentally. Such internal decay events are produced by the cosmogenic radio-isotopes Ge-68 and Co-60 and the neutrinoless double beta decay of Ge-76. Fixing the experimental acceptance of the double escape peak of the 2.614 MeV photon to 90%, the estimated survival probabilities at Qbb = 2.039 MeV are (86+-3)% for Ge-76 neutrinoless double beta decays, (4.5+-0.3)% for the Ge-68 daughter Ga-68, and (0.9+0.4-0.2)% for Co-60 decays.

physics.ins-det↗

Operation of a GERDA Phase I prototype detector in liquid argon and nitrogen

The GERDA (GERmanium Detector Array) experiment aiming to search for the neutrinoless double beta decay of 76Ge at the Laboratori Nazionali Del Gran Sasso (LNGS), Italy, will operate bare enriched high-purity germanium (HPGe) detectors in liquid argon. GERDA Phase I will use the enriched diodes from the previous Heidelberg-Moscow (HdM) and IGEX experiments. With the HPGe detectors mounted in a low-mass holder, GERDA aims at an excellent energy resolution and extremely low background. The goal is to check the claim for the neutrinoless double beta decay evidence in the HdM 76Ge experiment within one year of data taking. Before dismounting the enriched diodes from their cryostat, the performance parameters of the HdM and the IGEX detectors have been measured. The diodes have been removed from their cryostats, their dimensions measured and they have been put under va-cuum in a transportation container. They are now being refurbished for GERDA Phase I at Canberra Semiconductor NV. Before operating the enriched diodes, a non-enriched HPGe p-type detector mounted in a low-mass holder is operated in the liquid argon test facility of the GERDA Detector Laboratory (GDL) at LNGS. Since January 2006, the testing of the prototype detector is being carried out in the GDL as well as at the site of the detector manufacturer.

nucl-ex↗

Highly sensitive gamma-spectrometers of GERDA for material screening: Part I

The GERDA experiment aims to search for the neutrinoless double beta-decay of 76Ge and possibly for other rare processes. The sensitivity of the first phase is envisioned to be more than one order of magnitude better than in previous neutrinoless double beta-decay experiments. This implies that materials with ultra-low radioactive contamination need to be used for the construction of the detector and its shielding. Therefore the requirements on material screening include high-sensitivity low-background detection techniques and long measurement times. In this article, an overview of material-screening laboratories available to the GERDA collaboration is given, with emphasis on the gamma-spectrometry. Additionally, results of an intercomparison of the evaluation accuracy in these laboratories are presented.

physics.ins-det↗

Highly Sensitive Gamma-Spectrometers of GERDA for Material Screening: Part 2

The previous article about material screening for GERDA points out the importance of strict material screening and selection for radioimpurities as a key to meet the aspired background levels of the GERDA experiment. This is directly done using low-level gamma-spectroscopy. In order to provide sufficient selective power in the mBq/kg range and below, the employed gamma-spectrometers themselves have to meet strict material requirements, and make use of an elaborate shielding system. This article gives an account of the setup of two such spectrometers. Corrado is located in a depth of 15 m w.e. at the MPI-K in Heidelberg (Germany), GeMPI III is situated at the Gran-Sasso underground laboratory at 3500 m w.e. (Italy). The latter one aims at detecting sample activities of the order ~0.01 mBq/kg, which is the current state-of-the-art level. The applied techniques to meet the respective needs are discussed and demonstrated by experimental results.

physics.ins-det↗

LArGe: Background suppression using liquid argon (LAr) scintillation for 0$νββ$ decay search with enriched germanium (Ge) detectors

Measurements with a bare p-type high purity germanium diode (HPGe) submerged in a 19 kg liquid argon (LAr) scintillation detector at MPIK Heidelberg are reported. The liquid argon--germanium system (LArGe) is operated as a 4$π$ anti-Compton spectrometer to suppress backgrounds in the HPGe. This R&D is carried out in the framework of the GERDA experiment which searches for 0$νββ$ decays with HPGe detectors enriched in $^{76}$Ge. The goal of this work is to develop a novel method to discriminate backgrounds in 0$νββ$ search which would ultimately allow to investigate the effective neutrino mass free of background events down to the inverse mass hierarchy scale. Other applications in low-background counting are expected.

physics.ins-det↗