SearcharxivSearch

arXiv subjects

S. Sriram

Publications and source records attributed to S. Sriram.

At least 19 recordsLinked to original sources

Optical design of a direct fibre-fed MO-IFS for the NLOT

The initial optical design and performance analysis of a dual-channel fibre-fed Multi-Object Integral Field spectrograph (Mo-IFS) being designed for a future National Large Optical/Infrared Telescope (NLOT) in India. The front end will be a moveable lenslet+fiber based integral field unit. The spectrograph is designed to directly accept an f/4 beam from the approximately 200 optical fibers, each with a 100 um core diameter without additional fore-optics. The instrument consists of two optimized spectral channels covering wavelength ranges of 0.32-0.62 um (blue channel) and 0.60-1.00 um (red channel). The optical design aims to achieve moderate spectral resolutions of approximately R ~ 2700 in the blue channel and R ~ 2500 in the red channel while maintaining high throughput over a broad spectral range. The spectrograph architecture includes a fiber-fed entrance slit, collimator optics, dichroic beam splitting system, dispersive elements, and dedicated camera optics for each channel. Zemax simulations were carried out to evaluate image quality, spot size distribution, spectral resolution, and detector sampling across the full wavelength range. The current work presents the initial optical configuration, design methodology, and expected performance of the instrument.

astro-ph.IM

Design of a three-lens wide field corrector with aspherical surfaces for the 2.34-m VBT

We are developing a compact three-element Wide Field Corrector (WFC) with spherical and aspherical lenses for the 2.34 m Vainu Bappu Telescope (VBT) to enhance its field coverage for imaging and spectroscopic applications. The design consists of three optical elements, with at least one spherical lens movable to serve as an Atmospheric Dispersion Corrector (ADC), while the aspherical elements remain fixed to maintain optical stability. We are currently testing two design configurations, one with two spherical lenses and one aspherical lens, and another with two aspherical lenses and one spherical lens. The ADC is designed to correct atmospheric dispersion for zenith angles ranging from 0 degree to 60 degree. The system is optimized to operate over a wavelength range of 0.4 {\mu}m to 0.9 {\mu}m, targeting an effective field of view of about 0.5 degree. Considering the limited mechanical space available at the VBT prime focus, the design emphasizes compactness, ease of alignment, and manufacturability. The system achieves a mean D80 better than 0.3 arcsec and 0.23 arcsec for Design 1 and Design 2, respectively, at zenith, and maintains a mean D80 within 0.57 arcsec and 0.45 arcsec up to a zenith angle of 60 degree after atmospheric dispersion correction. Atmospheric dispersion at higher zenith angles (up to 60 degrees) is corrected using a movable lens element, enabling the system to preserve high image quality across the field.

astro-ph.IM

Congruences Relating Regular Partition Functions, a Genearalised Tau Function and Partition Function Weighted Composition Sums

Let $n$ and $t$ be positive integers with $t\geq 2$. Let $R_t(n)$ be the number of $t$-regular partitions of $n$. A class of functions, denoted $\tau_k(n)$, is defined as follows: \[q\prod_{m=1}^{\infty}(1-q^m)^k=\sum_{n=1}^{\infty}\tau_k(n)q^n, \] where $k$ is an integer. We express $\tau_k(n)$ as a binomial coefficient weighted partition sum. Consequently, we obtain congruence identities that relate $\tau_k(n)$, $R_t(n)$ and partition function weighted composition sums.

math.NT

Design and Fabrication of a lightweight three-lens corrector system for the 2.34-m Vainu Bappu Telescope

The Vainu Bappu Telescope (VBT) is a 2.34-m reflector, primarily supported on-axis field of view, offering high-resolution and low-to-medium resolution spectroscopic observations in its prime and Cassegrain configurations. This study presents the design and fabrication of a compact, lightweight, three-element wide-field corrector (WFC) utilizing three spherical lenses to cover a polychromatic wavelength range over a 30$'$ FoV at prime focus. The WFC design was optimized using ZEMAX, ensuring precision in aberrations, tolerances, and atmospheric dispersion. The fabricated lenses met stringent tolerances, with a $\pm$1 mm deviation in radius of curvature and $\pm$2 mm deviation in center thickness. A mechanical mount was developed to integrate all the WFC lenses, and wavefront error testing for the WFC system was performed using ZYGO interferometry, yielding a Wavefront Error of 0.05 $\lambda$. Laboratory performance tests were designed and conducted using a dedicated setup with achromatic lenses and 100 $\mu m$ fiber-coupled polychromatic light source showed a deviation of 0.1 pixel on-axis and 0.5 pixel at the extreme off-axis field compared to the ZEMAX design, demonstrating that the optical performance of WFC is with minimal aberrations across the entire FoV. The successful integration of the WFC at the VBT prime focus will increase the FoV, enabling the multi-fiber, multi-spectrograph setup in 30$'$ field that will facilitate both OMR and Echelle spectrograph to be used on the same night along with the addition of new multi-object spectrograph and an integral field unit instrument. This will mark a significant upgrade for the VBT, broadening its research potential, and expanding its observational versatility.

astro-ph.IM

A multi-functional fiber positioning system for Extremely Large Telescopes

We present a conceptual design for a fiber positioning system for multi-object high-resolution spectroscopy, designed to be compatible with the upcoming large telescopes with a wide field of view. The design incorporates multiple Atmospheric Dispersion Correctors (ADCs) and tip-tilt mirrors that receive non-telecentric input from individual targets and direct it to the ADCs. Here, we introduce a mechanical design for the fiber positioner that accommodates the optics and operates in a curved focal plane with a Radius of Curvature (R) of 3m. This mechanical design provides four degrees of freedom to access the focal volume, enhancing targeting efficiency. The proposed design and an efficient target allocation algorithm ensure a targeting efficiency of approximately 80-100% for a primary observation session. We also present a methodology for target assignment, positioning, and quantification based on sequential and Monte Carlo (MC) algorithms. This method has been tested on realistic fields with varying target densities to validate its performance.

astro-ph.IM

Design for Enabling Echelle and OMR Spectrograph Observations for Point and Extended Sources on the Same Night at VBT

The 2.34m Vainu Bappu Telescope (VBT) is a reflecting telescope that operates in two modes, prime focus and cassegrain focus, and is equipped with two instruments. In prime focus mode, the telescope has the F-number of f/3.25, and the High-Resolution Echelle Spectrograph (HRES) is employed through optical fiber. On the other hand, in cassegrain focus mode, the F-number is f/13, and the OMR Spectrograph (OMRS) is mounted for low and medium-resolution spectroscopy. Currently, the VBT faces a limitation: either the OMRS or the HRES can be used due to the switch in the heavy secondary mirror. To overcome this, we present a novel method enabling the OMRS to operate from prime mode alongside the HRES. The fiber setup for OMRS is optimized with a 25-lenslet + fiber-based Integral Field Unit (IFU) capable of observing both point and extended sources. The optimized lenslet, fiber, and fore optics design is undergoing lab testing. Our approach allows seamless operation of both spectrographs on the same night, enhancing the observational capabilities of astronomical studies with VBT.

astro-ph.IM

Theoretical Analysis of Fiber Arrangements for Improved Coupling Efficiency in the VBT High-Resolution Echelle Spectrograph

In fiber-based spectroscopy within telescopes, a prevailing limitation has been the necessity to align the fiber diameter with the telescope's seeing conditions, often characterized by the Full Width at Half Maximum of the point spread function. This alignment constraint captures around 50 \% of the incoming flux from any point source. Furthermore, the challenge is compounded when high-resolution spectroscopy is in play, as it often demands a minute slit width, further exacerbating flux loss. The essence of this paper lies in a comprehensive exploration, accomplished through theoretical simulations, of strategies aimed at enhancing the coupling efficiency of high-resolution spectrographs. The primary objective is to bolster the flux capture without compromising the critical aspect of spectral resolution. This research endeavors to unlock the potential for more effective utilization of high-resolution spectrographs to study celestial objects.

astro-ph.IM

Spectroscopic Investigation of Nebular Gas (SING): Instrument Design, Assembly and Calibration

The Spectroscopic Investigation of Nebular Gas (SING) is a near-ultraviolet (NUV) low-resolution spectrograph payload designed to operate in the NUV range, 1400 $\unicode{x212B}$ -- 2700 $\unicode{x212B}$, from a stable space platform. SING telescope has a primary aperture of 298 mm, feeding the light to the long-slit UV spectrograph. SING has a field of view (FOV) of 1$^{\circ}$, achieving a spatial resolution of 1.33 arc minute and spectral resolution of 3.7 $\unicode{x212B}$ ($R\sim600$) at the central wavelength. SING employs a micro-channel plate (MCP) with a CMOS readout-based photon-counting detector. The instrument is designed to observe diffuse sources such as nebulae, supernova remnants, and the interstellar medium (ISM) to understand their chemistry. SING was selected by the United Nations Office for Outer Space Affairs to be hosted on the Chinese Space Station. The instrument will undergo qualification tests as per the launch requirements. In this paper, we describe the hardware design, optomechanical assembly, and calibration of the instrument.

astro-ph.IM

Atmospheric dispersion corrector for a multi-object spectroscopic mode of HROS-TMT

Highly multiplexed spectroscopic surveys have changed the astronomy landscape in recent years. However, these surveys are limited to low and medium spectral resolution. High spectral resolution spectroscopy is often photon starved and will benefit from a large telescope aperture. Multiplexed high-resolution surveys require a wide field of view and a large aperture for a suitable large number of bright targets. This requirement introduces several practical difficulties, especially for large telescopes, such as the future ELTs. Some of the challenges are the need for a wide field atmospheric dispersion corrector and to deal with the curved non-telecentric focal plane. Here, we present a concept of Multi-Object Spectroscopy (MOS) mode for TMT High-Resolution Optical Spectrograph (HROS), we have designed an atmospheric dispersion corrector for individual objects that fit inside a fiber positioner. We present the ZEMAX design and the performance of the atmospheric dispersion corrector for all elevations accessible by TMT.

astro-ph.IM

Reduction of light output of plastic scintillator tiles during irradiation at cold temperatures and in low-oxygen environments

The advent of the silicon photomultiplier has allowed the development of highly segmented calorimeters using plastic scintillator as the active media, with photodetectors embedded in the calorimeter, in dimples in the plastic. To reduce the photodetector's dark current and radiation damage, the high granularity calorimeter designed for the high luminosity upgrade of the CMS detector at CERN's Large Hadron Collider will be operated at a temperature of about -30$^\circ$C. Due to flammability considerations, a low oxygen environment is being considered. However, the radiation damage to the plastic scintillator during irradiation in this operating environment needs to be considered. In this paper, we present measurements of the relative decrease of light output during irradiation of small plastic scintillator tiles read out by silicon photomultipliers. The irradiations were performed using a $^{60}\mathrm{Co}$ source both to produce the tiles' light and as a source of ionizing irradiation at dose rates of 0.3, 1.3, and $1.6\,$Gy/hr, temperatures of -30, -15, -5, and 0$^\circ$C, and with several different oxygen concentrations in the surrounding atmosphere. The effect of the material used to wrap the tile was also studied. Substantial temporary damage, which annealed when the sample was warmed, was seen during the low-temperature irradiations, regardless of the oxygen concentration and wrapping material. The relative light loss was largest with 3M$^{\tiny \textrm{TM}}$ Enhanced Specular Reflector Film wrapping and smallest with no wrapping, although due to the substantially higher light yield with wrapping, the final light output is largest with wrapping. The light loss was less at warmer temperatures. Damage with $3\%$ oxygen was similar to that in standard atmosphere. Evidence of a plateau in the radical density was seen for the 0$^\circ$C data.

physics.ins-det

In orbit performance of UVIT over the 5 years

Over the last 5 years, UVIT has completed observations of more than 500 proposals with ~ 800 unique pointings. In addition, regular planned monitoring observations have been made and from their analysis various key parameters related to in orbit performance of UVIT have been quantified. The sensitivities of the UV channels have remained steady indicating no effect of potential molecular contamination confirming the adequacy of all the protocols implemented for avoiding contamination. The quality of the PSF through the years confirms adequacy of thermal control measures. The early calibrations obtained during the Performance Verification (PV) phase have been further revised for more subtle effects. These include flat fields and detector distortions with greater precision. The operations of UVIT have also evolved through in orbit experience, e.g. tweaking of operational sequencing, protocol for recovery from bright object detection (BOD) shutdowns, parameters for BOD thresholds, etc. Finally, some effects of charged particle hits on electronics led to opimised strategy for regular resetting. The Near-UV channel was lost in one of such operations. All the above in-orbit experiences are presented here.

astro-ph.IM

Genetic Algorithm Based Resource Minimization in Network Code Based Peer-to-Peer Network

Block scheduling is difficult to implement in P2P network since there is no central coordinator. This problem can be solved by employing network coding technique which allows intermediate nodes to perform the coding operation instead of conventional store and forward the received data. There is a general assumption in this area of research so far that a target download rate is always attainable at every peer as long as coding operation is performed at all the nodes in the network. An interesting study is made that a maximum download rate can be attained by performing the coding operation at relatively small portion of the network. The problem of finding the minimal set of node to perform the coding operation and links to carry the coded data is called as a network code minimization problem (NCMP). It is proved to be NP hard problem. It can be solved using genetic algorithm (GA) because GA can be used to solve the diverse NP hard problem. A new NCMP model is proposed which considers both minimize the resources needed to perform coding operation and dynamic change in network topology due to disconnection. Based on this new NCMP model, an effective and novel GA is proposed by implementing problem specific GA operators into the evolutionary process. There is an attempt to implement the different compositions and several options of GA elements which worked well in many other problems and pick the one that works best for this resource minimization problem. Our simulation results prove that the proposed system outperforms the random selection and coding at all possible node mechanisms in terms of both download time and system throughput.

cs.NI

Additional Calibration of the Ultra-Violet Imaging Telescope on board AstroSat

Results of the initial calibration of the Ultra-Violet Imaging Telescope (UVIT) were reported earlier by Tandon et al. (2017). The results reported earlier were based on the ground calibration as well as the first observations in orbit. Some additional data from the ground calibration and data from more in-orbit observations have been used to improve the results. In particular, extensive new data from in-orbit observations have been used to obtain (a) new photometric calibration which includes (i) zero-points (ii) flat fields (iii) saturation, (b) sensitivity variations (c) spectral calibration for the near Ultra Violet (NUV; 2000 - 3000 Angstroms) and far Ultra-Violet (FUV; 1300 - 1800 Angstroms) gratings, (d) point spread function and (e) astrometric calibration which included distortion. Data acquired over the last three years show continued good performance of UVIT with no reduction in sensitivity in both the UV channels.

astro-ph.IM

Toward precision radial velocity measurements using Echelle spectrograph at Vainu Bappu Telescope

The Echelle spectrograph operating at Vainu Bappu Telescope (VBT) is a general purpose instrument designed for high resolution spectroscopy. It is being considered for precision Doppler measurements without altering the existing design and basic usage. However, the design level limitations and environmental perturbations are a major source of instability and systematic errors. As a result, a small Doppler signal in the stellar spectra is completely swamped by the large and uncontrolled instrumental drift. In this paper, we discuss some of the remedial measures we took to improve the radial velocity performance of the spectrograph. We show that a new auto-guider assembly has greatly reduced the mechanical jitter of the star image at the fibre input, making the illumination of the spectrograph slit at the other end stable. We have also installed an iodine absorption cell to track and eliminate the instrumental drifts to facilitate precision radial velocity observations. Furthermore, we have developed a generic algorithm that uses iodine exposures to extract the stellar radial velocities without the need for the complex forward modeling. Our algorithm is not accurate to the level of traditional iodine technique. However it is convenient to use on a low-cost general-purpose spectrograph targeting a moderate Radial Velocity (RV) precision at a few 10-100~$\textrm{ms}^{-1}$ level. Finally, we have demonstrated the usefulness of our approach by measuring the RV signal of a well known short-period, planet-hosting star.

astro-ph.IM

Prospect for UV observations from the Moon. III. Assembly and ground calibration of Lunar Ultraviolet Cosmic Imager (LUCI)

The Lunar Ultraviolet Cosmic Imager (LUCI) is a near-ultraviolet (NUV) telescope with all-spherical mirrors, designed and built to fly as a scientific payload on a lunar mission with Team Indus - the original Indian entry to the Google Lunar X-Prize. Observations from the Moon provide a unique opportunity of a stable platform with an unobstructed view of the space at all wavelengths due to the absence of atmosphere and ionosphere. LUCI is an 80 mm aperture telescope, with a field of view of 27.6'x 20.4' and a spatial resolution of 5'', will scan the sky in the NUV (200-320 nm) domain to look for transient sources. We describe here the assembly, alignment, and calibration of the complete instrument. LUCI is now in storage in a class 1000 clean room and will be delivered to our flight partner in readiness for flight.

astro-ph.IM

Sensing behavior of acetone vapors on TiO$_2$ nanostructures --- application of density functional theory

The electronic properties of TiO$_2$ nanostructure are explored using density functional theory. The adsorption properties of acetone on TiO$_2$ nanostructure are studied in terms of adsorption energy, average energy gap variation and Mulliken charge transfer. The density of states spectrum and the band structure clearly reveals the adsorption of acetone on TiO$_2$ nanostructures. The variation in the energy gap and changes in the density of charge are observed upon adsorption of acetone on n-type TiO$_2$ base material. The results of DOS spectrum reveal that the transfer of electrons takes place between acetone vapor and TiO$_2$ base material. The findings show that the adsorption property of acetone is more favorable on TiO$_2$ nanostructure. Suitable adsorption sites of acetone on TiO$_2$ nanostructure are identified at atomistic level. From the results, it is confirmed that TiO$_2$ nanostructure can be efficiently utilized as a sensing element for the detection of acetone vapor in a mixed environment.

cond-mat.mes-hall

In-orbit Calibrations of the Ultra-Violet Imaging Telescope

The Ultra-Violet Imaging Telescope (UVIT) is one of the payloads in ASTROSAT, the first Indian Space Observatory. The UVIT instrument has two 375mm telescopes: one for the far-ultraviolet (FUV) channel (1300--1800Å), and the other for the near-ultraviolet (NUV) channel (2000--3000Å) and the visible (VIS) channel (3200--5500Å). UVIT is primarily designed for simultaneous imaging in the two ultraviolet channels with spatial resolution better than 1.8 arcsec, along with provision for slit-less spectroscopy in the NUV and FUV channels.The results of in-orbit calibrations of UVIT are presented in this paper.

astro-ph.IM

Stability analysis of VBT Echelle spectrograph for precise radial velocity measurements

A fiber-fed Echelle spectrograph at 2.3 m Vainu Bappu Telescope (VBT), Kavalur, has been in operation since 2005. Owing to various technological advancements in precision spectroscopy in recent years, several research avenues have been opened in observational astronomy. These developments have created a demand to improve the Doppler precision of our spectrograph. Currently, the stability of the instrument is compromised by the temperature and pressure fluctuations inside the Echelle room. Further, a better wavelength calibration approach is needed to carefully track and disentangle the instrumental effects from stellar spectra. While planning a possible upgrade with an Iodine absorption gas cell, we measured the raw stability of the spectrograph using a series of calibration frames taken with the ThAr gas discharge lamp. The time series data were analysed with cross-correlation method and the shift in ThAr emission lines was accurately measured across different Echelle orders. In this paper, we present our stability analysis methodology and results for the Kavalur spectrograph. We also identify possible sources of error and discuss our strategy to mitigate them.

astro-ph.IM