Searcharxiv⌕ Search

arXiv subjects

S. T. P. Boyd

Publications and source records attributed to S. T. P. Boyd.

7 recordsLinked to original sources

Magneto-$ν$: Heavy neutral lepton search using $^{241}$Pu $β^-$ decays

The MAGNETO-$ν$ experiment searches for keV-scale heavy neutral leptons (HNLs) through precise measurements of the $β^-$-decay spectrum of $^{241}$Pu. We present spectra comprising a total of 194 million $β^-$ decays recorded using decay energy spectrometry with metallic magnetic calorimeters, representing the most statistically precise measurement of $^{241}$Pu $β^-$ decay to date. The $β$-endpoint energy was determined using $γ$ rays and X rays from an external $^{133}$Ba calibration source, yielding $Q_β= 22.273\,(33)$\,keV. The measured spectrum shows no statistically significant deviation from the allowed $β$-decay model. From a subset of the high-statistics data, we set an upper limit on the mixing of an 11.5-keV HNL with the electron neutrino, $|U_{e4}|^2 < 1.31 \times 10^{-3}$ at the 95\% confidence level.

hep-ex↗

Athermal phonon collection efficiency in diamond crystals for low mass dark matter detection

We explored the efficacy of lab-grown diamonds as potential target materials for the direct detection of sub-GeV dark matter~(DM) using metallic magnetic calorimeters~(MMCs). Diamond, with its excellent phononic properties and the low atomic mass of the constituent carbon, can play a crucial role in detecting low-mass dark matter particles. The relatively long electron-hole pair lifetime inside the crystal may provide discrimination power between the DM-induced nuclear recoil events and the background-induced electron recoil events. Utilizing the the fast response times of the MMCs and their unique geometric versatility, we deployed a novel methodology for quantifying phonon dynamics inside diamond crystals. We demonstrated that lab-grown diamond crystals fabricated via the chemical vapor deposition~(CVD) technique can satisfy the stringent quality requirements for sub-GeV dark matter searches. The high-quality polycrystalline CVD diamond showed a superior athermal phonon collection efficiency compared to that of the reference sapphire crystal, and achieved energy resolution 62.7~eV at the 8.05~keV copper fluorescence line. With this energy resolution, we explored the low-energy range below 100~eV and confirmed the existence of so-called low-energy excess~(LEE) reported by multiple cryogenic experiments.

physics.ins-det↗

Development of SQUID Array Amplifiers for the LiteBIRD CMB Satellite

LiteBIRD is an upcoming JAXA-led mission that aims to measure primordial gravitational waves in the B-mode polarization of the cosmic microwave background. It is set to launch in 2032. The LiteBIRD detector array consists of around 5000 TES detectors which are read out using digital frequency multiplexing over a bandwidth of 1-6 MHz. The multiplexing factor ranges from 58x to 68x. We are presently developing single-stage SQUID array amplifiers for LiteBIRD readout. Due to the reduced complexity and cost, and greater heritage from ground-based experiments such as the South Pole Telescope and Simons Array, single-stage SQUID array amplification is preferable for the first-stage amplification, as long as it can meet the requirements. The LiteBIRD single-stage SQUID Array is required to have high transimpedance amplification while maintaining a low input inductance and low dynamic resistance. In addition, the input-referred current noise must be very low, and the power dissipation must remain below about 100 nW. These requirements have non-trivial interactions. To maximize performance within these requirements we have performed lumped-element SQUID simulation. We find that by optimizing SQUID internal damping elements and inductive loading, good single-stage SQUID array performance can be obtained for LiteBIRD, including significant engineering margin.

physics.ins-det↗

Decay Energy Spectrometry for Improved Nuclear Material Analysis at the IAEA NML

Decay energy spectrometry (DES) is a novel radiometric technique for high-precision analysis of nuclear materials. DES employs the unique thermal detection physics of cryogenic microcalorimeters with ultra-high energy resolution and 100$\%$ detection efficiency to accomplish high precision decay energy measurements. Low-activity nuclear samples of 1 Bq or less, and without chemical separation, are used to provide elemental and isotopic compositions in a single measurement. Isotopic ratio precisions of 1 ppm - 1,000 ppm (isotope dependent), which is close to that of the mass spectrometry, have been demonstrated in 12-hour DES measurements of ~5 Bq samples of certified reference materials of uranium (U) and plutonium (Pu). DES has very different systematic biases and uncertainties, as well as different sensitivities to nuclides, compared to mass-spectrometry techniques. Therefore, the accuracy and confidence of nuclear material assays can be improved by combining this new technique with existing mass-spectrometry techniques. Commercial-level DES techniques and equipment are being developed for the implementation of DES at the Nuclear Material Laboratory (NML) of International Atomic Energy Agency (IAEA) to provide complementary measurements to the existing technologies. The paper describes details of DES measurement methods, as well as DES precision and accuracy to U and Pu standard sources to discuss its capability in analysis of nuclear safeguards samples.

physics.ins-det↗

Recent Advances in Frequency-Multiplexed TES Readout: Vastly Reduced Parasitics and an Increase in Multiplexing Factor with sub-Kelvin SQUIDs

Cosmic microwave background (CMB) measurements are fundamentally limited by photon statistics. Therefore, ground-based CMB observatories have been increasing the number of detectors that are simultaneously observing the sky. Thanks to the advent of monolithically fabricated transition edge sensor (TES) arrays, the number of on-sky detectors has been increasing exponentially for over a decade. The next-generation experiment CMB-S4 will increase this detector count by more than an order of magnitude from the current state-of-the-art to ~500,000. The readout of such a huge number of exquisitely precise sub-Kelvin sensors is feasible using an existing technology: frequency-domain multiplexing (fMux). To further optimize this system and reduce complexity and cost, we have recently made significant advances including the elimination of 4 K electronics, a massive decrease of parasitic in-series impedances, and a significant increase in multiplexing factor.

astro-ph.IM↗

The Large Enriched Germanium Experiment for Neutrinoless Double Beta Decay (LEGEND)

The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of $\sim$0.1 count /(FWHM$\cdot$t$\cdot$yr) in the region of the signal. The current generation $^{76}$Ge experiments GERDA and the MAJORANA DEMONSTRATOR utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0$νββ$ signal region of all 0$νββ$ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale $^{76}$Ge experiment. The collaboration aims to develop a phased 0$νββ$ experimental program with discovery potential at a half-life approaching or at $10^{28}$ years, using existing resources as appropriate to expedite physics results.

physics.ins-det↗

OpenSQUID: a flexible open-source software framework for the control of SQUID electronics

Commercially available computer-controlled SQUID electronics are usually delivered with software providing a basic user interface for adjustment of SQUID tuning parameters, such as bias current, flux offset, and feedback loop settings. However, in a research context it would often be useful to be able to modify this code and/or to have full control over all these parameters from researcher-written software. In the case of the STAR Cryoelectronics PCI/PFL family of SQUID control electronics, the supplied software contains modules for automatic tuning and noise characterization, but does not provide an interface for user code. On the other hand, the Magnicon SQUIDViewer software package includes a public application programming interface (API), but lacks auto-tuning and noise characterization features. To overcome these and other limitations, we are developing an "open-source" framework for controlling SQUID electronics which should provide maximal interoperability with user software, a unified user interface for electronics from different manufacturers, and a flexible platform for the rapid development of customized SQUID auto-tuning and other advanced features. We have completed a first implementation for the STAR Cryoelectronics hardware and have made the source code for this ongoing project available to the research community on SourceForge (http://opensquid.sourceforge.net) under the GNU public license.

cond-mat.supr-con↗