SearcharxivSearch

arXiv subjects

S. Thibado

Publications and source records attributed to S. Thibado.

7 recordsLinked to original sources

Search for Double Beta Decays of $^{134}$Xe with EXO-200 Phase II

EXO-200 was a leading double beta decay experiment consisting of a single-phase, enriched liquid xenon time projection chamber filled with an admixture of 80.672% $^{136}$Xe and 19.098% $^{134}$Xe. The detector operated at WIPP between 2010 and 2018 and was designed to search for double beta decay of $^{136}$Xe. Data was acquired in two phases separated by a period of detector upgrades. We report on the search for $0\nu\beta\beta$ and $2\nu\beta\beta$ decay of $^{134}$Xe with Phase II EXO-200 data, with median 90% C.L. exclusion sensitivity $T_{1/2}^{0\nu} \geq 3.7\times 10^{23}$ yr and $T_{1/2}^{2\nu} \geq 2.6 \times 10^{21}$ yr, respectively. No statistically significant signal is observed for either decay mode. We set a world-leading lower limit on the half-life of the neutrinoless decay mode of $^{134}$Xe of $T_{1/2}^{0\nu} \geq 8.7\times10^{23}$ (90% C.L.) and the second strongest constraint on the two-neutrino decay of $T_{1/2}^{2\nu} \geq 2.9\times10^{21}$ (90% C.L.), a 3-fold improvement over the EXO-200 Phase I measurement. New constraints are also set for the $2\nu\beta\beta$ and $0\nu\beta\beta$ decays of $^{134}$Xe to the lowest excited state of $^{134}$Ba.

nucl-ex

Search for Two-neutrino Double-Beta Decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ with the Complete EXO-200 Dataset

A new search for two-neutrino double-beta ($2νββ$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the addition of the Phase II dataset taken with an upgraded detector, the median 90$\%$ confidence level half-life sensitivity of $2νββ$ decay to the $0^+_1$ state of $^{136}\rm Ba$ is $2.9 \times 10^{24}~\rm yr$ using a total $^{136}\rm Xe$ exposure of $234.1~\rm kg~yr$. No statistically significant evidence for $2νββ$ decay to the $0^+_1$ state is observed, leading to a lower limit of $T^{2ν}_{1/2}(0^+ \rightarrow 0^+_1) > 1.4\times10^{24}~\rm yr$ at 90$\%$ confidence level, improved by 70$\%$ relative to the current world's best constraint.

hep-ex

Generative Adversarial Networks for Scintillation Signal Simulation in EXO-200

Generative Adversarial Networks trained on samples of simulated or actual events have been proposed as a way of generating large simulated datasets at a reduced computational cost. In this work, a novel approach to perform the simulation of photodetector signals from the time projection chamber of the EXO-200 experiment is demonstrated. The method is based on a Wasserstein Generative Adversarial Network - a deep learning technique allowing for implicit non-parametric estimation of the population distribution for a given set of objects. Our network is trained on real calibration data using raw scintillation waveforms as input. We find that it is able to produce high-quality simulated waveforms an order of magnitude faster than the traditional simulation approach and, importantly, generalize from the training sample and discern salient high-level features of the data. In particular, the network correctly deduces position dependency of scintillation light response in the detector and correctly recognizes dead photodetector channels. The network output is then integrated into the EXO-200 analysis framework to show that the standard EXO-200 reconstruction routine processes the simulated waveforms to produce energy distributions comparable to that of real waveforms. Finally, the remaining discrepancies and potential ways to improve the approach further are highlighted.

hep-ex

Search for MeV Electron Recoils from Dark Matter in EXO-200

We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total ${}^{136}\mathrm{Xe}$ exposure of $234.1\,\mathrm{kg}\,\mathrm{yr}$ we exclude new parameter space for the charged-current absorption cross-section for dark matter masses between $m_χ= 2.6\,\mathrm{MeV} - 11.6\,\mathrm{MeV}$ with a minimum of $6\times 10^{-51}\,\mathrm{cm}^2$ at $8.3\,\mathrm{MeV}$ at the $90\%$ confidence level.

hep-ex

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.

physics.ins-det

Search for Majoron-emitting modes of $^{136}$Xe double beta decay with the complete EXO-200 dataset

A search for Majoron-emitting modes of the neutrinoless double-beta decay of $^{136}$Xe is performed with the full EXO-200 dataset. This dataset consists of a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr, and includes data with detector upgrades that have improved the energy threshold relative to previous searches. A lower limit of T$_{1/2}^{\rm{^{136}Xe}}>$4.3$\cdot$10$^{24}$ yr at 90\% C.L. on the half-life of the spectral index $n=1$ Majoron decay was obtained, a factor of 3.6 more stringent than the previous limit from EXO-200, corresponding to a constraint on the Majoron-neutrino coupling constant of $|\langle g_{ee}^{M}\rangle|$$<(0.4$-$0.9)\cdot10^{-5}$. The lower threshold and the additional data taken resulted in a factor 8.4 improvement for the $n=7$ mode compared to the previous EXO search. This search provides the most stringent limits to-date on the Majoron-emitting decays of $^{136}$Xe with spectral indices $n=1,2,3,$ and 7.

hep-ex

Measurement of the Spectral Shape of the beta-decay of 137Xe to the Ground State of 137Cs in EXO-200 and Comparison with Theory

We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $β$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal-to-background ratio of more than 99-to-1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden non-unique $β$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.

nucl-ex