SearcharxivSearch

arXiv subjects

S. Trincaz-Duvoid

Publications and source records attributed to S. Trincaz-Duvoid.

4 recordsLinked to original sources

Destructive breakdown studies of irradiated LGADs at beam tests for the ATLAS HGTD

In the past years, it has been observed at several beam test campaigns that irradiated LGAD sensors break with a typical star shaped burn mark when operated at voltages much lower than those at which they were safely operated during laboratory tests. The study presented in this paper was designed to determine the safe operating voltage that these sensors can withstand. Many irradiated sensors from various producers were tested in two test beam facilities, DESY (Hamburg) and CERN-SPS (Geneva), as part of ATLAS High Granularity Timing Detector (HGTD) beam tests. The samples were placed in the beam and kept under bias over a long period of time in order to reach a high number of particles crossing each sensor. Both beam tests lead to a similar conclusion, that these destructive events begin to occur when the average electric field in the sensor becomes larger than 12 Volts per micrometre.

physics.ins-det

Performance in beam tests of Carbon-enriched irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS experiment to mitigate pile-up effects during the High Luminosity (HL) phase of the Large Hadron Collider (LHC) at CERN. Low Gain Avalanche Detectors (LGADs) will provide high-precision measurements of the time of arrival of particles at the HGTD, improving the particle-vertex assignment. To cope with the high-radiation environment, LGADs have been optimized by adding carbon in the gain layer, thus reducing the acceptor removal rate after irradiation. Performances of several carbon-enriched LGAD sensors from different vendors, and irradiated with high fluences of 1.5 and 2.5 x 10^15 neq/cm2, have been measured in beam test campaigns during the years 2021 and 2022 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few um. Collected charge, time resolution and hit efficiency measurements are presented. In addition, the efficiency uniformity is also studied as a function of the position of the incident particle inside the sensor pad.

physics.ins-det

Beam test results of IHEP-NDL Low Gain Avalanche Detectors(LGAD)

To meet the timing resolution requirement of up-coming High Luminosity LHC (HL-LHC), a new detector based on the Low-Gain Avalanche Detector(LGAD), High-Granularity Timing Detector (HGTD), is under intensive research in ATLAS. Two types of IHEP-NDL LGADs(BV60 and BV170) for this update is being developed by Institute of High Energy Physics (IHEP) of Chinese Academic of Sciences (CAS) cooperated with Novel Device Laboratory (NDL) of Beijing Normal University and they are now under detailed study. These detectors are tested with $5GeV$ electron beam at DESY. A SiPM detector is chosen as a reference detector to get the timing resolution of LGADs. The fluctuation of time difference between LGAD and SiPM is extracted by fitting with a Gaussian function. Constant fraction discriminator (CFD) method is used to mitigate the effect of time walk. The timing resolution of $41 \pm 1 ps$ and $63 \pm 1 ps$ are obtained for BV60 and BV170 respectively.

physics.ins-det

Beam test measurements of Low Gain Avalanche Detector single pads and arrays for the ATLAS High Granularity Timing Detector

For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at |z| = 3.5 m and covering the region 2.4 < |η| < 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 μm thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sensors with a surface area of 1.3x1.3 mm2 and arrays with 2x2 pads with a surface area of 2x2 mm^2 or 3x3 mm^2 each and different implant doses of the p+ multiplication layer. They are obtained from data collected during a beam test campaign in Autumn 2016 with a pion beam of 120 GeV energy at the CERN SPS. In addition to several quantities measured inclusively for each pad, the gain, efficiency and time resolution have been estimated as a function of the position of the incident particle inside the pad by using a beam telescope with a position resolution of few μm. Different methods to measure the time resolution are compared, yielding consistent results. The sensors with a surface area of 1.3x1.3 mm^2 have a time resolution of about 40 ps for a gain of 20 and of about 27 ps for a gain of 50 and fulfill the HGTD requirements. Larger sensors have, as expected, a degraded time resolution. All sensors show very good efficiency and time resolution uniformity.

physics.ins-det