Searcharxiv⌕ Search

arXiv subjects

S. Vasilyev

Publications and source records attributed to S. Vasilyev.

At least 37 records · Page 2Linked to original sources

Search for solar axions via axion-photon coupling with the Majorana Demonstrator

Axions were originally proposed to explain the strong-CP problem in QCD. Through the axion-photon coupling, the Sun could be a major source of axions, which could be measured in solid state detection experiments with enhancements due to coherent Primakoff-Bragg scattering. The Majorana Demonstrator experiment has searched for solar axions with a set of $^{76}$Ge-enriched high purity germanium detectors using a 33 kg-yr exposure collected between Jan. 2017 and Nov. 2019. A temporal-energy analysis gives a new limit on the axion-photon coupling as $g_{aγ}<1.45\times 10^{-9}$ GeV$^{-1}$ (95% C.I.) for axions with mass up to 100 eV/$c^2$. This improves laboratory-based limits between about 1 eV/$c^2$ and 100 eV/$c^2$.

nucl-ex↗

First results of the nuGeN experiment on coherent elastic neutrino-nucleus scattering

The nuGeN experiment is aimed to investigate neutrino properties using antineutrinos from the reactor of the Kalinin Nuclear Power Plant. The experimental setup is located at about 11 meters from the center of the 3.1 GWth reactor core. Scattering of the antineutrinos from the reactor is detected with low energy threshold high purity germanium detector. Passive and active shieldings are used to suppress all kinds of backgrounds coming from surrounding materials and cosmic radiation. The description of the experimental setup together with the first results is presented. The data taken in regimes with reactor ON (94.50 days) and reactor OFF (47.09 days) have been compared. No significant difference between spectra of two data sets is observed, i.e. no positive signals for coherent elastic neutrino-nucleus scattering are detected. Under Standard Model assumptions about coherent neutrino scattering an upper limit on a quenching parameter k < 0.26 (90 \% C.L.) in germanium has been set.

nucl-ex↗

Experimental study of 13C(α,n)16O reactions in the Majorana Demonstrator calibration data

Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied $^{13}$C($α,n)^{16}$O reactions induced by $α$-particles emitted within the calibration sources of the \textsc{Majorana Demonstrator}. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimated by using the 6129-keV $γ$-rays emitted from the excited $^{16}$O states that are populated when the incoming $α$-particles exceed the reaction Q-value. Thanks to the excellent energy performance of the \textsc{Demonstrator}'s germanium detectors, these characteristic photons can be clearly observed in the calibration data. Facilitated by \textsc{Geant4} simulations, a comparison between the observed 6129-keV photon rates and predictions by a TALYS-based software was performed. The measurements and predictions were found to be consistent, albeit with large statistical uncertainties. This agreement provides support for background projections from ($α,n$)-reactions in future double-beta decay search efforts.

nucl-ex↗

$α$-event Characterization and Rejection in Point-Contact HPGe Detectors

P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector's response to $α$ particles incident on the sensitive passivated and p+ surfaces, a previously poorly-understood source of background. The detector studied is identical to those in the MAJORANA DEMONSTRATOR experiment, a search for neutrinoless double-beta decay ($0νββ$) in $^{76}$Ge. $α$ decays on most of the passivated surface exhibit significant energy loss due to charge trapping, with waveforms exhibiting a delayed charge recovery (DCR) signature caused by the slow collection of a fraction of the trapped charge. The DCR is found to be complementary to existing methods of $α$ identification, reliably identifying $α$ background events on the passivated surface of the detector. We demonstrate effective rejection of all surface $α$ events (to within statistical uncertainty) with a loss of only 0.2% of bulk events by combining the DCR discriminator with previously-used methods. The DCR discriminator has been used to reduce the background rate in the $0νββ$ region of interest window by an order of magnitude in the MAJORANA DEMONSTRATOR, and will be used in the upcoming LEGEND-200 experiment.

physics.ins-det↗

The MAJORANA DEMONSTRATOR Readout Electronics System

The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the MAJORANA DEMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.

physics.ins-det↗

Signatures of muonic activation in the Majorana Demonstrator

Experiments searching for very rare processes such as neutrinoless double-beta decay require a detailed understanding of all sources of background. Signals from radioactive impurities present in construction and detector materials can be suppressed using a number of well-understood techniques. Background from in-situ cosmogenic interactions can be reduced by siting an experiment deep underground. However, the next generation of such experiments have unprecedented sensitivity goals of 10$^{28}$ years half-life with background rates of 10$^{-5}$cts/(keV kg yr) in the region of interest. To achieve these goals, the remaining cosmogenic background must be well understood. In the work presented here, Majorana Demonstrator data is used to search for decay signatures of meta-stable germanium isotopes. Contributions to the region of interest in energy and time are estimated using simulations, and compared to Demonstrator data. Correlated time-delayed signals are used to identify decay signatures of isotopes produced in the germanium detectors. A good agreement between expected and measured rate is found and different simulation frameworks are used to estimate the uncertainties of the predictions. The simulation campaign is then extended to characterize the background for the LEGEND experiment, a proposed tonne-scale effort searching for neutrinoless double-beta decay in $^{76}$Ge.

nucl-ex↗

ADC Nonlinearity Correction for the MAJORANA DEMONSTRATOR

Imperfections in analog-to-digital conversion (ADC) cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the Majorana Demonstrator 76Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC nonlinearites. A simple measurement protocol was developed that did not require sophisticated equipment or lengthy data taking campaigns. A slope-dependent hysteresis was observed and characterized. A correction applied to digitized waveforms prior to signal processing reduced the differential and integral nonlinearites by an order of magnitude, eliminating these as dominant contributions to the systematic energy uncertainty at the double-beta decay Q value.

physics.ins-det↗

The Majorana Demonstrator's Search for Double-Beta Decay of $^{76}$Ge to Excited States of $^{76}$Se

The Majorana Demonstrator is a neutrinoless double-beta decay search consisting of a low-background modular array of high-purity germanium detectors, $\sim2/3$ of which are enriched to 88\% in $^{76}$Ge. The experiment is also searching for double-beta decay of $^{76}$Ge to excited states (e.s.) in $^{76}$Se. $^{76}$Ge can decay into three daughter states of $^{76}$Se, with clear event signatures consisting of a $ββ$-decay followed by the prompt emission of one or two $γ$-rays. This results with high probability in multi-detector coincidences. The granularity of the Demonstrator detector array enables powerful discrimination of this event signature from backgrounds. Using 41.9~kg-y of isotopic exposure, the Demonstrator has set world leading limits for each e.s.\ decay of $^{76}$Ge, with 90\% CL lower half-life limits in the range of $(0.75-4.0)\times10^{24}$~y. In particular, for the $2ν$ transition to the first $0^+$ e.s.\ of $^{76}$Se, a lower half-life limit of $7.5\times10^{23}$~y at 90\% CL was achieved.

nucl-ex↗

Two-octave-wide (3-12 μm) mid-infrared frequency comb produced as an optical subharmonic in a nondispersive cavity

Coherent laser beams in the 3 to 20 μm region of the spectrum are most applicable for chemical sensing by addressing the strongest vibrational absorption resonances of the media. Broadband frequency combs in this spectral range are of special interest since they can be used as a powerful tool for molecular spectroscopy offering dramatic gains in speed, sensitivity, precision, and massive parallelism of data collection. Here we show that a frequency comb realized through subharmonic generation in an optical parametric oscillator (OPO) based on orientation-patterned gallium phosphide (OP-GaP) pumped by a Kerr-lens mode-locked 2.35-μm laser can reach a continuous wavelength span of 3-12 μm, thus covering most of the molecular 'signature' region. The key to achieving such a broad spectrum is to use a low-dispersion cavity entailing all gold-coated mirrors, minimally dispersive and optically thin intracavity elements, and a specially designed pump injector. The system features a smooth ultra-broadband spectral output that is phase coherent to the pump laser comb, 245-mW output power with high (>20%) optical conversion efficiency, and a possibility to reach close to unity conversion from a mode-locked drive, thanks to the non-dissipative downconversion processes and photon recycling.

physics.optics↗

Search for Tri-Nucleon Decay in the Majorana Demonstrator

The Majorana Demonstrator is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. We present the first limits for tri-nucleon decay-specific modes and invisible decay modes for Ge isotopes. We find a half-life limit of $4.9 \times 10^{25}$ yr for the decay $^{76}{\rm Ge(ppn)} \to {}^{73}{\rm Zn}\ e^+π^+$ and $4.7\times10^{25}$ yr for the decay $^{76}{\rm Ge(ppp)} \to ^{73}{\rm Cu}\ e^+π^+π^+$. The half-life limit for the invisible tri-proton decay mode of $^{76}$Ge was found to be $7.5\times10^{24}$ yr.

hep-ex↗

A Search for Neutrinoless Double-Beta Decay in $^{76}$Ge with 26 kg-yr of Exposure from the MAJORANA DEMONSTRATOR

The MAJORANA Collaboration is operating an array of high purity Ge detectors to search for the neutrinoless double-beta decay of $^{76}$Ge. The MAJORANA DEMONSTRATOR consists of 44.1 kg of Ge detectors (29.7 kg enriched to 88% in $^{76}$Ge) split between two modules constructed from ultra-clean materials. Both modules are contained in a low-background shield at the Sanford Underground Research Facility in Lead, South Dakota. We present updated results on the search for neutrinoless double-beta decay in $^{76}$Ge with $26.0\pm0.5$ kg-yr of enriched exposure. With the DEMONSTRATOR's unprecedented energy resolution of 2.53 keV FWHM at $Q_{ββ}$, we observe one event in the region of interest with 0.65 events expected from the estimated background, resulting in a lower limit on the $^{76}$Ge neutrinoless double-beta decay half-life of $2.7\times10^{25}$ yr (90% CL) with a median sensitivity of $4.8\times10^{25}$ yr (90% CL). Depending on the matrix elements used, a 90% CL upper limit on the effective Majorana neutrino mass in the range of 200-433 meV is obtained. The measured background in the low-background configurations is $11.9\pm2.0$ counts/(FWHM t yr).

nucl-ex↗

Multi-site event discrimination for the MAJORANA DEMONSTRATOR

The MAJORANA DEMONSTRATOR is searching for neutrinoless double-beta decay in 76Ge using arrays of point-contact germanium detectors operating at the Sanford Underground Research Facility. Background results in the neutrinoless double-beta decay region of interest from data taken during construction, commissioning, and the start of full operations have been recently published. A pulse shape analysis cut applied to achieve this result, named AvsE, is described in this paper. This cut is developed to remove events whose waveforms are typical of multi-site energy deposits while retaining (90 +/- 3.5)% of single-site events. This pulse shape discrimination is based on the relationship between the maximum current and energy, and tuned using 228Th calibration source data. The efficiency uncertainty accounts for variation across detectors, energy, and time, as well as for the position distribution difference between calibration and $0νββ$ events, established using simulations.

physics.ins-det↗

Recent results from the MAJORANA DEMONSTRATOR

The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decay in $^{76}$Ge and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modules of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, operating at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Commissioning of the experiment began in June 2015, followed by data production with the full detector array in August 2016. The ultra-low background and record energy resolution achieved by the MAJORANA DEMONSTRATOR enable a sensitive neutrinoless double-beta decay search, as well as additional searches for physics beyond the Standard Model. I will discuss the design elements that enable these searches, along with the latest results, focusing on the neutrinoless double-beta decay search. I will also discuss the current status and the future plans of the MAJORANA DEMONSTRATOR, as well as the plans for a future tonne-scale $^{76}$Ge experiment.

physics.ins-det↗

First Limit on the Direct Detection of Lightly Ionizing Particles for Electric Charge as Low as $e$/1000 with the \textsc{Majorana Demonstrator}

The \textsc{Majorana Demonstrator} is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly-ionizing particles with electrical charges less than $e$ are forbidden by the standard model but predicted by some of its extensions. If such particles exist, they might be detected in the \textsc{Majorana Demonstrator} by searching for multiple- detector events with individual-detector energy depositions down to 1 keV. This search is background free and no candidate events have been found in 285 days of data taking. New direct-detection limits are set for the flux of lightly ionizing particles for charges as low as $e$/1000.

hep-ex↗

The Majorana Demonstrator Status and Preliminary Results

The Majorana Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing the Majorana nature of the neutrino. Observation of this decay would imply violation of lepton number, that neutrinos are Majorana in nature, and provide information on the neutrino mass. The Majorana Demonstrator comprises 44.1 kg of p-type point-contact Ge detectors (29.7 kg enriched in 76Ge) surrounded by a low-background shield system. The experiment achieved a high efficiency of converting raw Ge material to detectors and an unprecedented detector energy resolution of 2.5 keV FWHM at Q$_{ββ}$. The Majorana collaboration began taking physics data in 2016. This paper summarizes key construction aspects of the Demonstrator and shows preliminary results from initial data.

nucl-ex↗

Low Background Materials and Fabrication Techniques for Cables and Connectors in the Majorana Demonstrator

The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus Ge-76. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale Ge-76-based search (the LEGEND collaboration). In the DEMONSTRATOR, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One special challenge of an ultra-pure environment is to develop reliable cables, connectors, and electronics that do not significantly contribute to the radioactive background of the experiment. This paper highlights the experimental requirements and how these requirements were met for the MAJORANA DEMONSTRATOR, including plans to upgrade the wiring for higher reliability in the summer of 2018. Also described are requirements for LEGEND R&D efforts underway to meet these additional requirements.

physics.ins-det↗

Design improvements to cables and connectors in the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radiopurity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. We will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.

physics.ins-det↗

Initial Results from the Majorana Demonstrator

The MAJORANA Collaboration has assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge with the goal of establishing the required background and scalability of a Ge-based next-generation ton-scale experiment. The MAJORANA DEMONSTRATOR consists of 44 kg of high-purity Ge (HPGe) detectors (30 kg enriched in $^{76}$Ge) with a low-noise p-type point contact (PPC) geometry. The detectors are split between two modules which are contained in a single lead and high-purity copper shield at the Sanford Underground Research Facility in Lead, South Dakota. Following a commissioning run that started in June 2015, the full detector array has been acquiring data since August 2016. We will discuss the status of the MAJORANA DEMONSTRATOR and initial results from the first physics run; including current background estimates, exotic low-energy physics searches, projections on the physics reach of the DEMONSTRATOR, and implications for a ton-scale Ge-based neutrinoless double-beta decay search.

physics.ins-det↗