SearcharxivSearch

arXiv subjects

S. W. Yang

Publications and source records attributed to S. W. Yang.

14 recordsLinked to original sources

Performances of a prototype point-contact germanium detector immersed in liquid nitrogen for light dark matter search

The CDEX-10 experiment searches for light weakly-interacting massive particles, a form of dark matter, at the China JinPing underground laboratory, where approximately 10 kg of germanium detectors are arranged in an array and immersed in liquid nitrogen. Herein, we report on the experimental apparatus, detector characterization, and spectrum analysis of one prototype detector. Owing to the higher rise-time resolution of the CDEX-10 prototype detector as compared with CDEX-1B, we identified the origin of an observed category of extremely fast events. For data analysis of the CDEX-10 prototype, we introduced and applied an improved bulk/surface event discrimination method. The results of the new method were compared to those of the CDEX-1B spectrum. Both sets of results showed good consistency in the 0--12 keVee energy range, except for the 8.0 keV K-shell X-ray peak from the external copper.

physics.ins-det

Neutron background measurements with a hybrid neutron detector at the Kuo-Sheng Reactor Neutrino Laboratory

We report in situ neutron background measurements at the Kuo-Sheng Reactor Neutrino Laboratory (KSNL) by a hybrid neutron detector (HND) with a data size of 33.8 days under identical shielding configurations as during the neutrino physics data taking. The HND consists of BC-501A liquid and BC-702 phosphor powder scintillation neutron detectors, which is sensitive to both fast and thermal neutrons, respectively. Neutron-induced events for the two channels are identified and differentiated by pulse shape analysis, such that background of both are simultaneously measured. The fast neutron fluxes are derived by an iterative unfolding algorithm. Neutron induced background in the germanium detector under the same fluxes, both due to cosmic-rays and ambient radioactivity, are derived and compared with the measurements. The results are valuable to background understanding of the neutrino data at the KSNL. In particular, neutron-induced background events due to ambient radioactivity as well as from reactor operation are negligible compared to intrinsic cosmogenic activity and ambient $γ$-activity. The detector concept and analysis procedures are applicable to neutron background characterization in similar rare-event experiments.

nucl-ex

Limits on light WIMPs with a 1 kg-scale germanium detector at 160 eVee physics threshold at the China Jinping Underground Laboratory

We report results of a search for light weakly interacting massive particle (WIMP) dark matter from the CDEX-1 experiment at the China Jinping Underground Laboratory (CJPL). Constraints on WIMP-nucleon spin-independent (SI) and spin-dependent (SD) couplings are derived with a physics threshold of 160 eVee, from an exposure of 737.1 kg-days. The SI and SD limits extend the lower reach of light WIMPs to 2 GeV and improve over our earlier bounds at WIMP mass less than 6 GeV.

hep-ex

Limits on Light Weakly Interacting Massive Particles from the First 102.8 kg ${\times}$ day Data of the CDEX-10 Experiment

We report the first results of a light weakly interacting massive particles (WIMPs) search from the CDEX-10 experiment with a 10 kg germanium detector array immersed in liquid nitrogen at the China Jinping Underground Laboratory with a physics data size of 102.8 kg day. At an analysis threshold of 160 eVee, improved limits of 8 $\times 10^{-42}$ and 3 $\times 10^{-36}$ cm$^{2}$ at a 90\% confidence level on spin-independent and spin-dependent WIMP-nucleon cross sections, respectively, at a WIMP mass ($m_χ$) of 5 GeV/${c}^2$ are achieved. The lower reach of $m_χ$ is extended to 2 GeV/${c}^2$.

hep-ex

Bulk and Surface Event Identification in p-type Germanium Detectors

The p-type point-contact germanium detectors have been adopted for light dark matter WIMP searches and the studies of low energy neutrino physics. These detectors exhibit anomalous behavior to events located at the surface layer. The previous spectral shape method to identify these surface events from the bulk signals relies on spectral shape assumptions and the use of external calibration sources. We report an improved method in separating them by taking the ratios among different categories of in situ event samples as calibration sources. Data from CDEX-1 and TEXONO experiments are re-examined using the ratio method. Results are shown to be consistent with the spectral shape method.

physics.ins-det

Design and Performance of a Hybrid Fast and Thermal Neutron Detector

We report the performance and characterization of a custom-built hybrid detector consisting of BC501A liquid scintillator for fast neutrons and BC702 scintillator for thermal neutrons. The calibration and the resolution of the BC501A liquid scintillator detector are performed. The event identification via Pulse Shape Discrimination (PSD) technique is developed in order to distinguish gamma, fast and thermal neutrons. Monte Carlo simulation packages are developed in GEANT4 to obtain actual neutron energy spectrum from the measured recoil spectrum. The developed methods are tested by reconstruction of 241AmBe(α, n) neutron spectrum.

physics.ins-det

Constraints on Axion couplings from the CDEX-1 experiment at the China Jinping Underground Laboratory

We report the results of searches for solar axions and galactic dark matter axions or axion-like particles with CDEX-1 experiment at the China Jinping Underground Laboratory, using 335.6 kg-days of data from a p-type point-contact germanium detector. The data are compatible with the background model and no excess signals are observed. Limits of solar axions on the model independent coupling $g_{Ae}<2.5\times10^{-11}$ from Compton, bremsstrahlung, atomic-recombination and deexcitation channel and $g^{\text{eff}}_{AN}\times g_{Ae}<6.1\times10^{-17}$ from $^{57}$Fe M1 transition at 90 % confidence level are derived. Within the framework of the DFSZ and KSVZ models, our results exclude the axion mass heavier than 0.9 eV/c$^{2}$ and 173 eV/c$^{2}$, respectively. The derived constraints for dark matter axions below 1 keV improves over the previous results.

hep-ex

Characterization and Performance of Germanium Detectors with sub-keV Sensitivities for Neutrino and Dark Matter Experiments

Germanium ionization detectors with sensitivities as low as 100 eVee (electron-equivalent energy) open new windows for studies on neutrino and dark matter physics. The relevant physics subjects are summarized. The detectors have to measure physics signals whose amplitude is comparable to that of pedestal electronic noise. To fully exploit this new detector technique, various experimental issues including quenching factors, energy reconstruction and calibration, signal triggering and selection as well as evaluation of their associated efficiencies have to be attended. The efforts and results of a research program to address these challenges are presented.

physics.ins-det

A Search of Low-Mass WIMPs with p-type Point Contact Germanium Detector in the CDEX-1 Experiment

The CDEX-1 experiment conducted a search of low-mass (< 10 GeV/c2) Weakly Interacting Massive Particles (WIMPs) dark matter at the China Jinping Underground Laboratory using a p-type point-contact germanium detector with a fiducial mass of 915 g at a physics analysis threshold of 475 eVee. We report the hardware set-up, detector characterization, data acquisition and analysis procedures of this experiment. No excess of unidentified events are observed after subtraction of known background. Using 335.6 kg-days of data, exclusion constraints on the WIMP-nucleon spin-independent and spin-dependent couplings are derived.

hep-ex

Limits on light WIMPs from the CDEX-1 experiment with a p-type point-contact germanium detector at the China Jingping Underground Laboratory

We report results of a search for light Dark Matter WIMPs with CDEX-1 experiment at the China Jinping Underground Laboratory, based on 53.9 kg-days of data from a p-type point-contact germanium detector enclosed by a NaI(Tl) crystal scintillator as anti-Compton detector. The event rate and spectrum above the analysis threshold of 475 eVee are consistent with the understood background model. Part of the allowed regions for WIMP-nucleus coherent elastic scattering at WIMP mass of 6-20 GeV are probed and excluded. Independent of interaction channels, this result contradicts the interpretation that the anomalous excesses of the CoGeNT experiment are induced by Dark Matter, since identical detector techniques are used in both experiments.

hep-ex

High performance current and spin diode of atomic carbon chain between transversely symmetric ribbon electrodes

We demonstrate that giant current and high spin rectification ratios can be achieved in atomic carbon chain devices connected between two symmetric ferromagnetic zigzag-graphene-nanoribbon electrodes. The spin dependent transport simulation is carried out by density functional theory combined with the non-equilibrium Green's function method. It is found that the transverse symmetries of the electronic wave functions in the nanoribbons and the carbon chain are critical to the spin transport modes. In the parallel magnetization configuration of two electrodes, pure spin current is observed in both linear and nonlinear regions. However, in the antiparallel configuration, the spin-up (down) current is prohibited under the positive (negative) voltage bias, which results in a spin rectification ratio of order 104. When edge carbon atoms are substituted with boron atoms to suppress the edge magnetization in one of the electrodes, we obtain a diode with current rectification ratio over 10e6.

cond-mat.mtrl-sci

Limits on light WIMPs with a germanium detector at 177 eVee threshold at the China Jinping Underground Laboratory

The China Dark Matter Experiment reports results on light WIMP dark matter searches at the China Jinping Underground Laboratory with a germanium detector array with a total mass of 20 g. The physics threshold achieved is 177 eVee ("ee" represents electron equivalent energy) at 50% signal efficiency. With 0.784 kg-days of data, exclusion region on spin-independent coupling with the nucleon is derived, improving over our earlier bounds at WIMP mass less than 4.6 GeV.

hep-ex

First results on low-mass WIMP from the CDEX-1 experiment at the China Jinping underground Laboratory

The China Dark matter Experiment collaboration reports the first experimental limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type point-contact germanium detector at the China Jinping underground Laboratory where the rock overburden is more than 2400 m. The energy threshold achieved was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N= 1.75 * 10^{-40} cm^{2} at 90% confidence level on the spin-independent cross-section at WIMP mass of 7 GeV before differentiating bulk signals from the surface backgrounds.

hep-ex

Electron Transport Properties of Atomic Carbon Nanowires between Graphene Electrodes

Long, stable and free-standing linear atomic carbon wires have been carved out from graphene recently [Meyer et al: Nature (London) 2008, 454, 319; Jin et al: Phys: Rev: Lett: 2009, 102, 205501]. They can be considered as the extremely narrow graphene nanoribbons or extremely thin carbon nanotubes. It might even be possible to make use of high strength and identical (without charity) carbon wires as a transport channel or on-chip interconnects for field-effect transistors. Here we investigate electron transport properties of linear atomic carbon wire-graphene junctions by nonequilibruim Green's function combined with density functional theory. For short wires, linear ballistic transport is observed in odd-numbered wire but destroyed by Peirerls distortion in even-numbered wire. For wires longer than 2.1 nm as fabricated above, however, the ballistic conductance of carbon wire-graphene junctions is remarkably robust against the Peierls distortion, structural imperfections, and hydrogen impurity adsorption of the linear carbon wires except oxygen impurities. As such, the epoxy groups might be the origin of low conductance experimentally observed in carbon wires. Moreover, double atomic carbon wires exhibit negative differential resistance (NDR) effect.

physics.atm-clus