SearcharxivSearch

arXiv subjects

S. White

Publications and source records attributed to S. White.

At least 19 recordsLinked to original sources

Advances in photocathode development for PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targeting time resolutions of tens of picoseconds for minimum ionising particles (MIPs). Initial single-pad prototypes achieved time resolutions of $\sigma<25$ ps, demonstrating strong potential for High Energy Physics (HEP) applications and beyond. The objective of this paper is a comprehensive characterisation of photocathodes, with a strong focus on robust materials while preserving excellent timing performance. The study includes laboratory measurements of optical and resistive properties, along with beam tests using 150 GeV/$c$ muons to evaluate the time resolution and photoelectron yield for various photocathodes. The best performance was obtained by a 5 nm Cesium Iodide (CsI) photocathode, reaching $\sigma = 10.9 \pm 0.3$ ps with more than 30 extracted photoelectrons, representing the most precise time resolution achieved by PICOSEC Micromegas to date. Metallic and carbon-based photocathodes, including Titanium (Ti), Boron Carbide (B$_4$C) and Diamond-Like Carbon (DLC), were also tested, with Ti and B$_4$C emerging as the most promising alternatives, achieving $\sigma \approx 30$ ps with about 5 extracted photoelectrons. These results demonstrate that improved robustness can be achieved while maintaining excellent time resolution, supporting the feasibility of using the PICOSEC Micromegas concept in future experiments.

physics.ins-det

Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area

The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision at the level of tens of picoseconds, this technology is particularly suited for time-of-flight (TOF) applications in particle physics and potentially medical imaging. Beam tests with a 150~GeV/$c$ muon beam have been carried out on a large-area (10~$\times$~10~cm$^{2}$) prototype equipped with a cesium iodide (CsI) photocathode. Using an oscilloscope-based single-channel readout, timing measurements on two individual pads of the detector have yielded resolutions of $\approx$ 48 ps and $\approx$ 52 ps under different biasing conditions respectively.

physics.ins-det

Spatial resolution improvement of PICOSEC Micromegas precise timing detectors

The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15ps. While tileable prototypes with 10x10 channels feature 1x1 cm^2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5mm spatial resolution with 3.5mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously.

physics.ins-det

Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET

The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micromegas-based photodetector with a photocathode. This configuration allows the fast photoelectron-induced signal to suppress the intrinsic time jitter of gaseous detectors, enabling sub-20 ps timing precision while preserving the robustness and scalability of micro-pattern gaseous detector technologies. The 96-pad PICOSEC-MM detector is a large-area demonstrator optimized for precision timing in high-energy physics, building on research and development insights from earlier 7-pad resistive prototypes to validate scalability, uniformity, and robustness for the ENUBET project. It employs a 2.5 nm diamond-like carbon photocathode and a Micromegas board with a surface resistivity of 10 megaohms per square, and was characterized using 150 GeV/c muons at the CERN SPS beamline, with one-third of the active area instrumented per run. A dedicated alignment procedure for multi-pad PICOSEC-MM systems was used to reconstruct pad centers and merge measurements across regions, yielding a timing resolution of 43 ps and uniform signal arrival time distributions over the tested area. Mechanical flatness was identified as a key factor, with planarity tolerances within 10 micrometers required to maintain good timing resolution, and the successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept toward robust, high-granularity, picosecond-level gaseous timing detectors for monitored neutrino beam experiments such as ENUBET.

physics.ins-det

Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors

We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and photocathode at the CERN SPS H4 beam line. This work provides a proof of concept for the use of resistive layer technology in gaseous timing detectors, demonstrating that robustness can be improved without compromising the excellent timing performance of PICOSEC Micromegas. Different resistive architectures and values were explored to optimize stability and ensure reliable long-term operation in challenging experimental environments. The prototype with a 10M{\Omega} resistive layer achieved the best overall performance, with a timing resolution of 22.900 {\pm} 0.002 ps and a spatial resolution of 1.190 {\pm} 0.003 mm, while charge sharing across multiple pads enabled combined timing resolutions below 28 ps. A lower-resistivity (200k{\Omega}) configuration exhibited enhanced charge spread, leading to minor systematic offsets in reconstructed pad centers, yet maintained robust timing and spatial performance. Capacitive charge-sharing architectures improved spatial resolution in some regions but suffered from signal attenuation and nonuniform charge distributions, resulting in slightly degraded timing (33.300 {\pm} 0.002 ps) and complex localization patterns. Mechanical precision, particularly readout planarity and photocathode alignment, was identified as critical for uniform detector response. These studies benchmark the potential of resistive layers for gaseous timing detectors and provide a foundation for scalable designs with optimized timing and spatial resolution across diverse experimental applications.

physics.ins-det

A comparison of time-dependent Cloudy astrophysical code simulations with experimental X-ray spectra from keV laser-generated argon plasmas

We have generated strongly photoionized Ar plasmas in experiments designed to use primarily X-ray L-shell line emission generated from Ag foils irradiated by the VULCAN high-power laser at the UK Central Laser Facility. The principle of the experiment is that use of line emission rather than the usual sub-keV quasi-blackbody source allows keV radiation to play a more dominant role compared to softer X-rays and thus mimic the effect of a blackbody with a higher effective spectral temperature. Our aim is to reproduce in the laboratory the extreme photoionization conditions found in accretion-powered astrophysical sources. In this paper, we compare the experimental results on K-$\beta$ X-ray Ar spectra with modelling using the time-dependent version of the Cloudy astrophysical code. The results indicate that photoionized laboratory plasmas can be successfully modelled with codes such as Cloudy that have been developed for application to astrophysical sources. Our comparison of simulation and experiment shows that the flux of sub-keV photons that photoionize the outer-shell electrons can have a significant effect, and that detailed measurements of the X-ray drive spectrum across all photon energy ranges are crucial for accurate modelling of experiments.

astro-ph.HE

Resonant Island Trapping in a Fourth-Generation Synchrotron Light Source

We report the first direct observation of nonlinear resonance island trapping in a fourth-generation light source with working points far from the excited resonance and examine the nonlinear dynamics and properties of the trapped beam. The discovered dynamics of island trapping may help understand bunch purity and halo formation issues, create additional experimental capabilities for photon science applications, and present means of nonlinear characterization of the machine optics.

physics.acc-ph

PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration

PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 $\times$ 10 $\text{cm}^2$ area prototypes and a 20 $\times$ 20 $\text{cm}^2$ prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.

physics.ins-det

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30 ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20 ps respectively.

physics.ins-det

Optimization of LYSO crystals and SiPM parameters for the CMS MIP timing detector

For the High-Luminosity (HL-LHC) phase, the upgrade of the Compact Muon Solenoid (CMS) experiment at CERN will include a novel MIP Timing Detector (MTD). The central part of MTD, the barrel timing layer (BTL), is designed to provide a measurement of the time of arrival of charged particles with a precision of 30 ps at the beginning of HL-LHC, progressively degrading to 60 ps while operating in an extremely harsh radiation environment for over a decade. In this paper we present a comparative analysis of the time resolution of BTL module prototypes made of LYSO:Ce crystal bars read out by silicon photo-multipliers (SiPMs). The timing performance measured in beam test campaigns is presented for prototypes with different construction and operation parameters, such as different SiPM cell sizes (15, 20, 25 and 30 $\rm \mu m$), SiPM manufacturers and crystal bar thicknesses. The evolution of time resolution as a function of the irradiation level has been studied using non-irradiated SiPMs as well as SiPMs exposed up to $2\times 10^{14}~n_{eq}/cm^2$ fluence. The key parameters defining the module time resolution such as SiPM characteristics (gain, photon detection efficiency, radiation induced dark count rate) and crystal properties (light output and dimensions) are discussed. These results have informed the final choice of the MTD barrel sensor configuration and offer a unique starting point for the design of future large-area scintillator-based timing detectors in either low or high radiation environments.

physics.ins-det

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a~time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

physics.ins-det

A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.

physics.ins-det

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitics on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. The detectors were initially tested in the laboratory environment. Finally, the timing performance of detectors with different pad sizes was verified using a Minimum Ionizing Particle (MIP) beam test. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5$\pm$0.8 ps was achieved with a 10 mm diameter readout pad size detector.

physics.ins-det

TOFHIR2: The readout ASIC of the CMS Barrel MIP Timing Detector

The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected along the HL-LHC lifetime. We present an overview of the TOFHIR2 requirements and design, simulation results and measurements with TOFHIR2 ASICs. The measurements of TOFHIR2 associated to sensor modules were performed in different test setups using internal test pulses or blue and UV laser pulses emulating the signals expected in the experiment. The measurements show a time resolution of 24 ps initially during Beginning of Operation (BoO) and 58 ps at End of Operation (EoO) conditions, matching well the BTL requirements. We also showed that the time resolution is stable up to the highest expected MIP rate. Extensive radiation tests were performed, both with x-rays and heavy ions, showing that TOFHIR2 is not affected by the radiation environment during the experiment lifetime.

physics.ins-det

Integration of thermo-electric coolers into the CMS MTD SiPM arrays for operation under high neutron fluence

The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read out with Silicon Photomultipliers (SiPMs). A major challenge for the operation of such a detector is the extremely high radiation level, of about $2\times10^{14}$ 1 MeV(Si) Eqv. n/cm$^2$, that will be integrated over a decade of operation of the High Luminosity Large Hadron Collider (HL-LHC). Silicon Photomultipliers exposed to this level of radiation have shown a strong increase in dark count rate and radiation damage effects that also impact their gain and photon detection efficiency. For this reason during operations the whole detector is cooled down to about $-35^{\circ}$C. In this paper we illustrate an innovative and cost-effective solution to mitigate the impact of radiation damage on the timing performance of the detector, by integrating small thermo-electric coolers (TECs) on the back of the SiPM package. This additional feature, fully integrated as part of the SiPM array, enables a further decrease in operating temperature down to about $-45^{\circ}$C. This leads to a reduction by a factor of about two in the dark count rate without requiring additional power budget, since the power required by the TEC is almost entirely offset by a decrease in the power required for the SiPM operation due to leakage current. In addition, the operation of the TECs with reversed polarity during technical stops of the accelerator can raise the temperature of the SiPMs up to $60^{\circ}$C (about $50^{\circ}$C higher than the rest of the detector), thus accelerating the annealing of radiation damage effects and partly recovering the SiPM performance.

physics.ins-det

Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes

Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the detection systems. The PICOSEC Micromegas detector has demonstrated the ability to time 150\,GeV muons with a sub-25\,ps precision. Driven by detailed simulation studies and a phenomenological model which describes stochastically the dynamics of the signal formation, new PICOSEC designs were developed that significantly improve the timing performance of the detector. PICOSEC prototypes with reduced drift gap size ($\sim$\SI{119}{\micro\metre}) achieved a resolution of 45\,ps in timing single photons in laser beam tests (in comparison to 76\,ps of the standard PICOSEC detector). Towards large area detectors, multi-pad PICOSEC prototypes with segmented anodes has been developed and studied. Extensive tests in particle beams revealed that the multi-pad PICOSEC technology provides also very precise timing, even when the induced signal is shared among several neighbouring pads. Furthermore, new signal processing algorithms have been developed, which can be applied during data acquisition and provide real time, precise timing.

physics.ins-det

L-shell X-ray conversion yields for laser-irradiated tin and silver foils

We have employed the VULCAN laser facility to generate a laser plasma X-ray source for use in photoionisation experiments. A nanosecond laser pulse with an intensity of order ${10}^{15}$ W{cm}$^{-2}$ was used to irradiate thin Ag or Sn foil targets coated onto a parylene substrate, and the L-shell emission in the $3.3-4.4$ keV range was recorded for both the laser-irradiated and non-irradiated sides. Both the experimental and simulation results show higher laser to X-ray conversion yields for Ag compared with Sn, with our simulations indicating yields approximately a factor of two higher than found in the experiments. Although detailed angular data were not available experimentally, the simulations indicate that the emission is quite isotropic on the laser-irradiated side, but shows close to a cosine variation on the non-irradiated side of the target as seen experimentally in previous work.

physics.plasm-ph

Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D

This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51 collaboration which has become the critical organization for the promotion of MPGDs and all aspects of their production, characterization, simulation, and uses in an expanding array of experimental configurations. For the Snowmass 2021 study, a number of Letters of Interest were received that illustrate ongoing developments and expansion of the use of MPGDs. In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow.

physics.ins-det