SearcharxivSearch

arXiv subjects

S. Ye

Publications and source records attributed to S. Ye.

6 recordsLinked to original sources

Commissioning and Full Realization of the PLASEN System at BRIF

A PLASEN (Precision LAser Spectroscopy for Exotic Nuclei) system, consisting of a compact radio-frequency quadrupole cooler-buncher (RFQ-cb) and a collinear resonance ionization spectroscopy setup, has now been fully commissioned with radioactive ion beams at the Beijing Radioactive Ion-beam Facility (BRIF). Using both stable and radioactive Rb ion beams from BRIF, we demonstrated that the large beam energy spread observed at BRIF has been successfully handled by employing the RFQ-cb, enabling the delivery of high-quality bunched radioactive ion beams for collinear resonance ionization spectroscopy experiments. Under these conditions, we performed laser spectroscopy of exotic nuclei, achieving high resolution (about 100 MHz spectral linewidth) and high sensitivity (up to 1:200 efficiency). This fully operational PLASEN system will serve as a state-of-the-art experimental platform at BRIF for research in multiple fields such as nuclear, atomic and molecular physics.

physics.ins-det

A region-wide, multi-year set of crop field boundary labels for Africa

African agriculture is undergoing rapid transformation. Annual maps of crop fields are key to understanding the nature of this transformation, but such maps are currently lacking and must be developed using advanced machine learning models trained on high resolution remote sensing imagery. To enable the development of such models, we delineated field boundaries in 33,746 Planet images captured between 2017 and 2023 across the continent using a custom labeling platform with built-in procedures for assessing and mitigating label error. We collected 42,403 labels, including 7,204 labels arising from tasks dedicated to assessing label quality (Class 1 labels), 32,167 from sites mapped once by a single labeller (Class 2) and 3,032 labels from sites where 3 or more labellers were tasked to map the same location (Class 4). Class 1 labels were used to calculate labeller-specific quality scores, while Class 1 and 4 sites mapped by at least 3 labellers were used to further evaluate label uncertainty using a Bayesian risk metric. Quality metrics showed that label quality was moderately high (0.75) for measures of total field extent, but low regarding the number of individual fields delineated (0.33), and the position of field edges (0.05). These values are expected when delineating small-scale fields in 3-5 m resolution imagery, which can be too coarse to reliably distinguish smaller fields, particularly in dense croplands, and therefore requires substantial labeller judgement. Nevertheless, previous work shows that such labels can train effective field mapping models. Furthermore, this large, probabilistic sample on its own provides valuable insight into regional agricultural characteristics, highlighting variations in the median field size and density. The imagery and vectorized labels along with quality information is available for download from two public repositories.

cs.CV

Design and performance testing of a T0 detector for the CSR External-target Experiment

The Cooling Storage Ring (CSR) External-target Experiment (CEE) at the Heavy Ion Research Facility in Lanzhou (HIRFL), China, is the first multi-purpose nuclear physics experimental device to operate in the Giga electron-volt (GeV) energy range. The primary goals of the CEE are to study the bulk properties of dense matter and to understand the quantum chromo-dynamic (QCD) phase diagram by measuring the charged particles produced in heavy-ion collisions in the target region with a large acceptance. The CEE is a spectrometer that focuses on charged final-state particle measurements running on the HIRFL-CSR. The time-of-flight (TOF) system is critical for identifying charged particles in the GeV energy region. In the CEE spectrometer, the TOF system consists of three parts: T0, internal TOF, and external TOF, which are used for the final-state particle identification. The T0 detector provides a high-precision start time for the TOF system by measuring the crossing time of the heavy ion beam. This study details the design, performance simulation, and performance testing of the T0 detector. The simulation results and heavy-ion beam test show that the T0 detector prototype has an excellent time resolution, which is better than 30 ps, and fulfills the requirements of the CEE.

physics.ins-det

Energetic electron precipitation driven by electromagnetic ion cyclotron waves from ELFIN's low altitude perspective

We review comprehensive observations of electromagnetic ion cyclotron (EMIC) wave-driven energetic electron precipitation using data from the energetic electron detector on the Electron Losses and Fields InvestigatioN (ELFIN) mission, two polar-orbiting low-altitude spinning CubeSats, measuring 50-5000 keV electrons with good pitch-angle and energy resolution. EMIC wave-driven precipitation exhibits a distinct signature in energy-spectrograms of the precipitating-to-trapped flux ratio: peaks at 0.5 MeV which are abrupt (bursty) with significant substructure (occasionally down to sub-second timescale). Multiple ELFIN passes over the same MLT sector allow us to study the spatial and temporal evolution of the EMIC wave - electron interaction region. Using two years of ELFIN data, we assemble a statistical database of 50 events of strong EMIC wave-driven precipitation. Most reside at L=5-7 at dusk, while a smaller subset exists at L=8-12 at post-midnight. The energies of the peak-precipitation ratio and of the half-peak precipitation ratio (our proxy for the minimum resonance energy) exhibit an L-shell dependence in good agreement with theoretical estimates based on prior statistical observations of EMIC wave power spectra. The precipitation ratio's spectral shape for the most intense events has an exponential falloff away from the peak (i.e., on either side of 1.45 MeV). It too agrees well with quasi-linear diffusion theory based on prior statistics of wave spectra. Sub-MeV electron precipitation observed concurrently with strong EMIC wave-driven 1MeV precipitation has a spectral shape that is consistent with efficient pitch-angle scattering down to 200-300 keV by much less intense higher frequency EMIC waves. These results confirm the critical role of EMIC waves in driving relativistic electron losses. Nonlinear effects may abound and require further investigation.

physics.space-ph

Spatial Variations in the Dust-to-Gas Ratio of Enceladus' Plume

On day 138 of 2010, the plume of dust and gas emerging from Enceladus' South Polar Terrain passed between the Sun and the Cassini spacecraft. This solar occultation enabled Cassini's Ultraviolet Imaging Spectrograph (UVIS) and the Visual and Infrared Mapping Spectrometer (VIMS) to obtain simultaneous measurements of the plume's gas and dust components along the same lines of sight. The UVIS measurements of the plume's gas content are described in Hansen et al. (2011, GRL 38:11202) , while this paper describes the VIMS data and the information they provide about the plume's particle content. Together, the VIMS and UVIS measurements reveal that the plume material above Baghdad and Damascus sulci has a dust-to-gas mass ratio that is roughly an order of magnitude higher than the material above Alexandria and Cairo sulci. Similar trends in the plume's dust-to-gas ratio are also found in data obtained when Cassini flew through the plume in 2009, during which time the Ion and Neutral Mass Spectrometer (INMS), Radio and Plasma Wave Science instrument (RPWS) and Cosmic Dust Analyzer (CDA) instruments made in-situ measurements of the plume's gas and dust densities (Dong et al. 2015 JGR 120:915-937). These and other previously-published systematic differences in the material erupting from different fissures likely reflect variations in subsurface conditions across Encealdus' South Polar Terrain.

astro-ph.EP

Lateral ferromagnetic domain control in Cr2O3/Pt/Co positive exchange bias system

We investigated the perpendicular exchange bias (PEB) switching from negative- to positive-exchange bias state for Cr2O3/Pt/Co exchange coupling thin film system exhibiting positive exchange bias phenomena. By changing Pt spacer layer thickness or measurements temperature, we demonstrated the control of two kind of intermediate state of the switching; the double hysteresis loop indicating local, non-averaged PEB, and single hysteresis loop indicating averaged PEB. We proposed the way to control the lateral ferromagnetic domain though the control of PEB magnitude.

cond-mat.mtrl-sci