SearcharxivSearch

arXiv subjects

Saeedeh Ketabi

Publications and source records attributed to Saeedeh Ketabi.

2 recordsLinked to original sources

Novel Method for More Efficient Optimizing the Knowledge-Based Planning: Specific Voxels of each Structure Influenced by Dominant Beamlets (SVSIDB)

There is a huge problem and time-consuming computation to optimize the IMRT treatment plan. Extracting the optimized plan from the predicted 3D3 so-called optimizing the KBP is also involved in this challenge. Some algorithms and methods have been presented for clustering and down-sampling the voxels to make the problem smaller, in recent years. In the current research, a novel down-sampling method is presented for optimizing the knowledge-based planning more efficiently. The concept of SVSIDB and corresponding down-sampling algorithm are proposed under title of SMP-2. The algorithm has been run on the data of 30 patients from the Open-KBP dataset. For each patient, there are 19 sets of dose prediction data in this dataset. Therefore, a total of 570 KBP-optimizing problems have been solved by applying the QuadLin model in the CVX framework. Resulted plans are evaluated and compared regarding two main fields which are the quality of the treatment plan as well as the computation efficiency. Solve time is the evaluation criteria for the latter field i.e. computation efficiency. The results of the current study indicated a remarkable improvement in the computation efficiency. Accordingly, the proposed method, SMP-2, reduced the average solving time by 46% in comparison to the full-data QuadLin model. The results also show an up to 53% reduction in solve time along with up to 22% improvement in clinical criteria compared to the previous research. Evaluation of the research results indicated that the SVSIDB has not only reduced the solve time but also improved the quality of the treatment plans. This is a remarkable achievement of the proposed model compared to the previous research and confirmed the significant effectiveness of the SVSIDB method which has the potential of even more improvement of the computation efficiency.

physics.med-ph

How to Apply 3D3 Prediction? A Novel Mathematical Model to Generate Pareto Optimal Clinical Applicable IMRT Treatment Plan On the Foundation of Dose Prediction and Prescription

In this paper knowledge based planning has been revolutionized via a novel mathematical model which converts three dimensional dose distribution (3D3) prediction to a clinical utilizable IMRT treatment plan. Presented model has benefited from both prescribed dose as well as predicted dose and its objective function includes both quadratic and linear phrases, so it was called QuadLin model. The model has been run on the data of 30 patients with head and neck cancer randomly selected from the Open KBP dataset. For each patient, there are 19 sets of dose prediction data in this database. Therefore, a total of 570 problems have been solved in the CVX framework and the results have been evaluated by two plan quality approaches: 1- DVH points differences, and 2- satisfied clinical criteria. The results of the current study indicate a strong significant improvement in clinical indicators compared to the reference plan of the dataset, 3D3 predictions, as well as the results of previous researches. Accordingly, on average for 570 problems and total ROIs, clinical indicators have improved by more than 21% and 15% compared to the predicted dose and previous research, respectively.

math.OC