SearcharxivSearch

arXiv subjects

Sakib Mahmud

Publications and source records attributed to Sakib Mahmud.

10 recordsLinked to original sources

A Novel 1D Generative Adversarial Network-based Framework for Atrial Fibrillation Detection using Restored Wrist Photoplethysmography Signals

Atrial fibrillation (AF) increases the risk of stroke. Electrocardiogram (ECG) is used for AF detection, while photoplethysmography (PPG) is simple to use and appropriate for long-term monitoring. We have developed a novel approach to detect AF from smartwatch-based wrist PPG signals. To the best of our knowledge, this is the first study to employ 1D CycleGAN for the reconstruction of 1D wrist PPG signals, since the quality of wrist PPG signals is very poor due to motion artifacts and acquisition site limitations. Our proposed approach is validated on a dataset of 21,278 10s long wrist PPG segments. The dataset was divided into two halves and two experiments were conducted. One half was used for training and the other half for testing and vice versa. Our classification model (Self-AFNet) with 1D-CycleGAN for restoration achieves an accuracy of 96.41% and 97.09% for both splits, respectively. There is a noteworthy improvement in accuracy (2.94% and 5.08% for test splits, respectively) for restored signals as compared to unrestored PPG. AF detection task was also performed using ECG signals with the matched PPG signals to assess the validity of employing reconstructed PPG-based AF classification. Self-AFNet managed to achieve an accuracy of 98.07% and 98.97%, respectively using two ECG splits which is comparable to the performance of AF detection utilizing reconstructed PPG segments. This study reflects that reconstructed wrist PPG signals acquired from wearable devices can be used for reliable detection of atrial fibrillation, which can significantly help in the reduction of the risk of stroke.

eess.SP

A Novel Deep Learning Technique for Morphology Preserved Fetal ECG Extraction from Mother ECG using 1D-CycleGAN

Monitoring the electrical pulse of fetal heart through a non-invasive fetal electrocardiogram (fECG) can easily detect abnormalities in the developing heart to significantly reduce the infant mortality rate and post-natal complications. Due to the overlapping of maternal and fetal R-peaks, the low amplitude of the fECG, systematic and ambient noises, typical signal extraction methods, such as adaptive filters, independent component analysis, empirical mode decomposition, etc., are unable to produce satisfactory fECG. While some techniques can produce accurate QRS waves, they often ignore other important aspects of the ECG. Our approach, which is based on 1D CycleGAN, can reconstruct the fECG signal from the mECG signal while maintaining the morphology due to extensive preprocessing and appropriate framework. The performance of our solution was evaluated by combining two available datasets from Physionet, "Abdominal and Direct Fetal ECG Database" and "Fetal electrocardiograms, direct and abdominal with reference heartbeat annotations", where it achieved an average PCC and Spectral-Correlation score of 88.4% and 89.4%, respectively. It detects the fQRS of the signal with accuracy, precision, recall and F1 score of 92.6%, 97.6%, 94.8% and 96.4%, respectively. It can also accurately produce the estimation of fetal heart rate and R-R interval with an error of 0.25% and 0.27%, respectively. The main contribution of our work is that, unlike similar studies, it can retain the morphology of the ECG signal with high fidelity. The accuracy of our solution for fetal heart rate and R-R interval length is comparable to existing state-of-the-art techniques. This makes it a highly effective tool for early diagnosis of fetal heart diseases and regular health checkups of the fetus.

eess.SP

Optical, Thermal, and Electrical Analysis of Perovskite Solar Cell with Grated CdS and Embedded Plasmonic Au Nanoparticles

We propose a novel approach to enhance the performance of perovskite solar cells (PSCs) by incorporating grated Cadmium Sulfide (CdS) and plasmonic gold nanoparticles (Au NPs) into the absorber layer. The CdS grating acts as the electron transport layer and penetrates into the perovskite absorber layer, increasing the absorption of the active layer and reducing the electron-hole recombination rate. The plasmonic Au NPs enhance the absorption in the infrared region by scattering and trapping the incident light. We perform a coupled optical and electrical study that shows a significant improvement in the short circuit current density (JSC) and power conversion efficiency (PCE) of the PSC after introducing the CdS grating and plasmonic Au NPs. Specifically, we observe a 48% increase in average optical absorption from 800 nm to 1400 nm and a 7.42 mA/cm^2 increase in JSC. We also find that the PCE of the PSC is increased by 7.91% when comparing the planar reference structure (without the CdS grating and the plasmonic Au NP). However, metal nanoparticles introduce ohmic losses and temperature rise in the solar cell. We analyze the non-radiative heat profile, electric field distribution, and temperature distribution across the PSC. We observe a temperature increase of approximately 14 K above the ambient temperature for the grated CdS layer with incorporated Au NPs, which is comparable to the temperature increase observed in the planar reference structure. Our results have the potential to pave the way for the development of highly efficient and stable PSCs in the future.

physics.optics

Design, Implementation, and Performance Evaluation of a Fiber Bragg Gratings(FBG) based Smart Insole to Measure Plantar Pressure and Temperature

Various foot complications can be easily avoided by continuous monitoring of foot plantar temperature and pressure. In this work, the design, characterization, and implementation of a Fiber Bragg Gratings (FBG) based smart insole capable of simultaneously measuring plantar pressure and temperature has been reported. The instrumented insole was tested and verified during static and gait exercises. The paper also provides a comparison of the developed optoelectronic-based solution with a commercially available and widely used plantar pressure measurement and analysis system and a lab-made, electronic sensor-based smart insole that can measure both plantar temperature and pressure. It was shown that even though the commercially available expensive system is very robust and highly precise due to many sensing units on the insole, the developed insole with a smaller number of sensors can provide both plantar temperature and pressure with reasonable precision while displaying both foot pressure and temperature maps, and gait cycle plots in real-time. The FBG-based solution is comfortable and safer than the other systems being compared. Thus, confirming the effectiveness of the proposed solution as an addition to the research area for detecting foot complications non-invasively using foot insoles.

eess.SY

Design and Implementation of a Complete Wearable Smart Insole Solution to Measure Plantar Pressure and Temperature

A complete smart insole solution that continuously monitors the foot plantar pressure and temperature can detect foot complications early and that too from the convenience of the user home. Widespread health complications such as Diabetic Mellitus need continuous foot complication monitoring to avoid severe complications. With that motivation, this paper provides a detailed design of a wearable insole using popular off-the-shelf sensors to monitor foot plantar pressure and temperature. The design provides details of which temperature and pressure to be used, circuit configuration for characterizing the sensors, and the considerations for developing a compact Printed Circuit board design using appropriate microcontrollers and communication protocol. The system also provides details of how the foot pressure and temperature data from the subjects using the sensors can be transferred wirelessly using a low-power consuming communication protocol to a central device where the data will be recorded. The investigation can help in developing a low-cost, feasible and portable foot monitoring system for patients by facilitating real-time, home monitoring of foot condition using Gait Cycle or Foot Pressure patterns and temperature heterogeneity between two feet. The proposed system will work in real-time.

physics.med-ph

A Shallow U-Net Architecture for Reliably Predicting Blood Pressure (BP) from Photoplethysmogram (PPG) and Electrocardiogram (ECG) Signals

Cardiovascular diseases are the most common causes of death around the world. To detect and treat heart-related diseases, continuous Blood Pressure (BP) monitoring along with many other parameters are required. Several invasive and non-invasive methods have been developed for this purpose. Most existing methods used in the hospitals for continuous monitoring of BP are invasive. On the contrary, cuff-based BP monitoring methods, which can predict Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP), cannot be used for continuous monitoring. Several studies attempted to predict BP from non-invasively collectible signals such as Photoplethysmogram (PPG) and Electrocardiogram (ECG), which can be used for continuous monitoring. In this study, we explored the applicability of autoencoders in predicting BP from PPG and ECG signals. The investigation was carried out on 12,000 instances of 942 patients of the MIMIC-II dataset and it was found that a very shallow, one-dimensional autoencoder can extract the relevant features to predict the SBP and DBP with the state-of-the-art performance on a very large dataset. Independent test set from a portion of the MIMIC-II dataset provides an MAE of 2.333 and 0.713 for SBP and DBP, respectively. On an external dataset of forty subjects, the model trained on the MIMIC-II dataset, provides an MAE of 2.728 and 1.166 for SBP and DBP, respectively. For both the cases, the results met British Hypertension Society (BHS) Grade A and surpassed the studies from the current literature.

eess.SP

QUCoughScope: An Artificially Intelligent Mobile Application to Detect Asymptomatic COVID-19 Patients using Cough and Breathing Sounds

In the break of COVID-19 pandemic, mass testing has become essential to reduce the spread of the virus. Several recent studies suggest that a significant number of COVID-19 patients display no physical symptoms whatsoever. Therefore, it is unlikely that these patients will undergo COVID-19 test, which increases their chances of unintentionally spreading the virus. Currently, the primary diagnostic tool to detect COVID-19 is RT-PCR test on collected respiratory specimens from the suspected case. This requires patients to travel to a laboratory facility to be tested, thereby potentially infecting others along the way.It is evident from recent researches that asymptomatic COVID-19 patients cough and breath in a different way than the healthy people. Several research groups have created mobile and web-platform for crowdsourcing the symptoms, cough and breathing sounds from healthy, COVID-19 and Non-COVID patients. Some of these data repositories were made public. We have received such a repository from Cambridge University team under data-sharing agreement, where we have cough and breathing sound samples for 582 and 141 healthy and COVID-19 patients, respectively. 87 COVID-19 patients were asymptomatic, while rest of them have cough. We have developed an Android application to automatically screen COVID-19 from the comfort of people homes. Test subjects can simply download a mobile application, enter their symptoms, record an audio clip of their cough and breath, and upload the data anonymously to our servers. Our backend server converts the audio clip to spectrogram and then apply our state-of-the-art machine learning model to classify between cough sounds produced by COVID-19 patients, as opposed to healthy subjects or those with other respiratory conditions. The system can detect asymptomatic COVID-19 patients with a sensitivity more than 91%.

eess.AS

COVID-19 Infection Localization and Severity Grading from Chest X-ray Images

Coronavirus disease 2019 (COVID-19) has been the main agenda of the whole world, since it came into sight in December 2019 as it has significantly affected the world economy and healthcare system. Given the effects of COVID-19 on pulmonary tissues, chest radiographic imaging has become a necessity for screening and monitoring the disease. Numerous studies have proposed Deep Learning approaches for the automatic diagnosis of COVID-19. Although these methods achieved astonishing performance in detection, they have used limited chest X-ray (CXR) repositories for evaluation, usually with a few hundred COVID-19 CXR images only. Thus, such data scarcity prevents reliable evaluation with the potential of overfitting. In addition, most studies showed no or limited capability in infection localization and severity grading of COVID-19 pneumonia. In this study, we address this urgent need by proposing a systematic and unified approach for lung segmentation and COVID-19 localization with infection quantification from CXR images. To accomplish this, we have constructed the largest benchmark dataset with 33,920 CXR images, including 11,956 COVID-19 samples, where the annotation of ground-truth lung segmentation masks is performed on CXRs by a novel human-machine collaborative approach. An extensive set of experiments was performed using the state-of-the-art segmentation networks, U-Net, U-Net++, and Feature Pyramid Networks (FPN). The developed network, after an extensive iterative process, reached a superior performance for lung region segmentation with Intersection over Union (IoU) of 96.11% and Dice Similarity Coefficient (DSC) of 97.99%. Furthermore, COVID-19 infections of various shapes and types were reliably localized with 83.05% IoU and 88.21% DSC. Finally, the proposed approach has achieved an outstanding COVID-19 detection performance with both sensitivity and specificity values above 99%.

eess.IV

Detection and severity classification of COVID-19 in CT images using deep learning

Since the breakout of coronavirus disease (COVID-19), the computer-aided diagnosis has become a necessity to prevent the spread of the virus. Detecting COVID-19 at an early stage is essential to reduce the mortality risk of the patients. In this study, a cascaded system is proposed to segment the lung, detect, localize, and quantify COVID-19 infections from computed tomography (CT) images Furthermore, the system classifies the severity of COVID-19 as mild, moderate, severe, or critical based on the percentage of infected lungs. An extensive set of experiments were performed using state-of-the-art deep Encoder-Decoder Convolutional Neural Networks (ED-CNNs), UNet, and Feature Pyramid Network (FPN), with different backbone (encoder) structures using the variants of DenseNet and ResNet. The conducted experiments showed the best performance for lung region segmentation with Dice Similarity Coefficient (DSC) of 97.19% and Intersection over Union (IoU) of 95.10% using U-Net model with the DenseNet 161 encoder. Furthermore, the proposed system achieved an elegant performance for COVID-19 infection segmentation with a DSC of 94.13% and IoU of 91.85% using the FPN model with the DenseNet201 encoder. The achieved performance is significantly superior to previous methods for COVID-19 lesion localization. Besides, the proposed system can reliably localize infection of various shapes and sizes, especially small infection regions, which are rarely considered in recent studies. Moreover, the proposed system achieved high COVID-19 detection performance with 99.64% sensitivity and 98.72% specificity. Finally, the system was able to discriminate between different severity levels of COVID-19 infection over a dataset of 1,110 subjects with sensitivity values of 98.3%, 71.2%, 77.8%, and 100% for mild, moderate, severe, and critical infections, respectively.

eess.IV

PPG2ABP: Translating Photoplethysmogram (PPG) Signals to Arterial Blood Pressure (ABP) Waveforms using Fully Convolutional Neural Networks

Cardiovascular diseases are one of the most severe causes of mortality, taking a heavy toll of lives annually throughout the world. The continuous monitoring of blood pressure seems to be the most viable option, but this demands an invasive process, bringing about several layers of complexities. This motivates us to develop a method to predict the continuous arterial blood pressure (ABP) waveform through a non-invasive approach using photoplethysmogram (PPG) signals. In addition we explore the advantage of deep learning as it would free us from sticking to ideally shaped PPG signals only, by making handcrafted feature computation irrelevant, which is a shortcoming of the existing approaches. Thus, we present, PPG2ABP, a deep learning based method, that manages to predict the continuous ABP waveform from the input PPG signal, with a mean absolute error of 4.604 mmHg, preserving the shape, magnitude and phase in unison. However, the more astounding success of PPG2ABP turns out to be that the computed values of DBP, MAP and SBP from the predicted ABP waveform outperforms the existing works under several metrics, despite that PPG2ABP is not explicitly trained to do so.

eess.SP