Searcharxiv⌕ Search

arXiv subjects

Sami G. Tantawi

Publications and source records attributed to Sami G. Tantawi.

6 recordsLinked to original sources

A Prototype Hybrid Mode Cavity for Heterodyne Axion Detection

In the heterodyne approach to axion detection, axion dark matter induces transitions between two modes of a microwave cavity, resulting in a parametrically enhanced signal power. We describe the fabrication and characterization of a prototype normal conducting cavity specifically optimized for heterodyne detection. Corrugations on the cavity walls support linearly polarized hybrid modes which maximize the signal power while strongly suppressing noise. We demonstrate tuning mechanisms which allow one mode's frequency to be scanned across a 4 MHz range, while suppressing cross-coupling noise by at least 80 dB. A future superconducting cavity with identical geometry to our prototype would have the potential to probe orders of magnitude beyond astrophysical bounds.

physics.ins-det↗

Transformative Technology for FLASH Radiation Therapy: A Snowmass 2021 White Paper

Conventional cancer therapies include surgery, radiation therapy, chemotherapy, and, more recently, immunotherapy. These modalities are often combined to improve the therapeutic index. The general concept of radiation therapy is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and high radiation beams that deliver radiation dose with high conformality, e.g., protons and ions. However, treatment and cure are still limited by normal tissue radiation toxicity, with many patients experiencing acute and long-term side effects. Recently, however, a fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. The dose delivery conditions are not yet fully characterized. Still, it is currently estimated that large doses of 10 Gy or more delivered in 200 ms or less produce normal tissue sparing effects yet effectively kill tumor cells. There is a great opportunity, but also many technical challenges, for the accelerator community to create the required dose rates with novel and compact accelerators to ensure the safe delivery of FLASH radiation beams.

physics.med-ph↗

An Advanced NCRF Linac Concept for a High Energy e$^+$e$^-$ Linear Collider

We have explored a concept for an advanced Normal-Conducting Radio-Frequency (NCRF) C-band linear accelerator (linac) structure to achieve a high gradient, high power e$^+$e$^-$ linear collider in the TeV class. This design study represents the first comprehensive investigation for an emerging class of distributed coupling accelerator topology exploring nominal cavity geometries, frequency and temperature of operation. The structure features internal manifolds for distributing RF power separately to each cell, permitting the full structure geometry to be designed for high shunt impedance and low breakdown. Optimized within operational constraints, we find that it is advantageous for the structure to be cooled directly by liquid nitrogen (LN), further increasing the shunt impedance. A crucial part of this design process has been cost optimization, which is largely driven by the cost of peak RF power. The first operation of a distributed coupling structure at cryogenic temperatures and the nominal operating gradient 120 MeV/m is also presented, demonstrating the feasibility of achieving high-gradient performance with a cryogenically-cooled normal-conducting accelerating structure.

physics.acc-ph↗

A Compact, Planar, Eight-Port Waveguide Power Divider/Combiner: The Cross Potent Superhybrid

In this letter, we present a novel four-way divider/combiner in rectangular waveguide. The design is completely two-dimensional in the h-plane, with eight-fold mirror symmetry, and is based on a recent four-port hybrid design [6]. In combining mode, it can function as a phased array with four inputs and four outputs. The planar nature of this design provides advantages, such as the freedom to increase the waveguide height beyond the over-moding limit in order to reduce field strengths. Along with its open geometry, this makes it ideal for high-power applications where rf break down is a concern. Design criteria, field-solver simulation results, and prototype measurements are presented.

physics.acc-ph↗

New Development in RF Pulse Compression

Several pulse compression systems have been proposed for future linear collider. Most of these systems require hundreds of kilometers of low-loss waveguide runs. To reduce the waveguide length and improve the efficiency of these systems, components for multimoding, active switches and non-reciprocal elements are being developed. In the multimoded systems a waveguide is utilized several times by sending different signals over different modes. The multimoded components needed for these systems have to be able to handle hundreds of megawatts of rf power at the X-band frequency and above. Consequently, most of these components are overmoded. We present the development of multimoded components required for such systems. We also present the development efforts towards overmoded active component such as switches and overmoded non-reciprocal components such as circulators and isolators.

physics.acc-ph↗

2D Simulation of High-Efficiency Cross-Field RF Power Sources

An efficient method for frequency domain analysis of 2D cross-field devices is presented. This work was done to analyze and design high efficiency magnetrons. Arbitrary device-geometries are described by a piecewise planar boundary. The method is based on an expansion of the electromagnetic fields into a set of cavity eigenmodes. In order to obtain the self-consistent solution, iterations are performed until the energy balance is reached. A boundary integration method is used to take into account space charge effects. The cavity eigenmodes are found by a method based on the scattering matrix technique. The geometry is divided into regions. The boundary contour mode-matching method is used to obtain the scattering matrices for each region. Electromagnetic fields in each region are expanded into a series of plane waves. Due to choice of plane wave expansion, all integration in the mode-matching process is carried out analytically. The scattering matrices of the regions are combined using a generalized scattering matrix technique to obtain the scattering matrix for the full geometry, and then the eigenmode resonance frequencies and the fields. Periodic boundary condition is used for the field calculation and the particle tracking.

physics.acc-ph↗