SearcharxivSearch

arXiv subjects

Samir H. Patel

Publications and source records attributed to Samir H. Patel.

14 recordsLinked to original sources

The Daily Dose: Workflow-Integrated Large Language Model Automation for Clinical Summarization and Trial Identification in Radiation Oncology

Objective: To describe the design and early clinical evaluation of The Daily Dose (TDD), an LLM-driven, automated clinical summarization and clinical-trial identification system integrated into routine radiation oncology practice. Design: Mixed-methods evaluation using a cross-sectional, anonymous clinician survey administered after 1 month of system deployment. Exposure: Daily automated delivery of physician-specific email summaries generated using RadOnc-GPT, including patient schedules, concise EHR-derived clinical-status summaries, and automated identification of potentially relevant clinical trials for new or consult visits. Main Outcomes and Measures: Primary outcomes included self-reported usability, satisfaction, perceived usefulness, perceived impact on workflow, time savings, and intention for continued use. Internal consistency reliability was assessed using Cronbach's $\alpha$. Results: Among 55 respondents, 52 (94.5\%) worked in radiation oncology, and 38 (69.1\%) were attending physicians. Most participants (83.6\%) reported using TDD daily or several times per week. Mean (SD) scores were 3.89 (1.04) for usability and satisfaction, 3.43 (1.24) for perceived usefulness, and 3.80 (1.17) for impact and future use (5-point Likert scale). Overall satisfaction was positively associated with perceived time savings ($p < .001$). Participants reported variable time savings, with 27\% estimating $\geq 10$ minutes saved per day. The questionnaire demonstrated excellent internal consistency (overall Cronbach's $\alpha$ = 0.97).

cs.CL

A Multimodal Clinically Informed Coarse-to-Fine Framework for Longitudinal CT Registration in Proton Therapy

Proton therapy offers superior organ-at-risk sparing but is highly sensitive to anatomical changes, making accurate deformable image registration (DIR) across longitudinal CT scans essential. Conventional DIR methods are often too slow for emerging online adaptive workflows, while existing deep learning-based approaches are primarily designed for generic benchmarks and underutilize clinically relevant information beyond images. To address this gap, we propose a clinically scalable coarse-to-fine deformable registration framework that integrates multimodal information from the proton radiotherapy workflow to accommodate diverse clinical scenarios. The model employs dual CNN-based encoders for hierarchical feature extraction and a transformer-based decoder to progressively refine deformation fields. Beyond CT intensities, clinically critical priors, including target and organ-at-risk contours, dose distributions, and treatment planning text, are incorporated through anatomy- and risk-guided attention, text-conditioned feature modulation, and foreground-aware optimization, enabling anatomically focused and clinically informed deformation estimation. We evaluate the proposed framework on a large-scale proton therapy DIR dataset comprising 1,222 paired planning and repeat CT scans across multiple anatomical regions and disease types. Extensive experiments demonstrate consistent improvements over state-of-the-art methods, enabling fast and robust clinically meaningful registration.

cs.CV

AI in Proton Therapy Treatment Planning: A Review

Purpose: Proton therapy provides superior dose conformity compared to photon therapy, but its treatment planning is challenged by sensitivity to anatomical changes, setup/range uncertainties, and computational complexity. This review evaluates the role of artificial intelligence (AI) in improving proton therapy treatment planning. Materials and methods: Recent studies on AI applications in image reconstruction, image registration, dose calculation, plan optimization, and quality assessment were reviewed and summarized by application domain and validation strategy. Results: AI has shown promise in automating contouring, enhancing imaging for dose calculation, predicting dose distributions, and accelerating robust optimization. These methods reduce manual workload, improve efficiency, and support more personalized planning and adaptive planning. Limitations include data scarcity, model generalizability, and clinical integration. Conclusion: AI is emerging as a key enabler of efficient, consistent, and patient-specific proton therapy treatment planning. Addressing challenges in validation and implementation will be essential for its translation into routine clinical practice.

physics.med-ph

An Automated Retrieval-Augmented Generation LLaMA-4 109B-based System for Evaluating Radiotherapy Treatment Plans

Purpose: To develop a retrieval-augmented generation (RAG) system powered by LLaMA-4 109B for automated, protocol-aware, and interpretable evaluation of radiotherapy treatment plans. Methods and Materials: We curated a multi-protocol dataset of 614 radiotherapy plans across four disease sites and constructed a knowledge base containing normalized dose metrics and protocol-defined constraints. The RAG system integrates three core modules: a retrieval engine optimized across five SentenceTransformer backbones, a percentile prediction component based on cohort similarity, and a clinical constraint checker. These tools are directed by a large language model (LLM) using a multi-step prompt-driven reasoning pipeline to produce concise, grounded evaluations. Results: Retrieval hyperparameters were optimized using Gaussian Process on a scalarized loss function combining root mean squared error (RMSE), mean absolute error (MAE), and clinically motivated accuracy thresholds. The best configuration, based on all-MiniLM-L6-v2, achieved perfect nearest-neighbor accuracy within a 5-percentile-point margin and a sub-2pt MAE. When tested end-to-end, the RAG system achieved 100% agreement with the computed values by standalone retrieval and constraint-checking modules on both percentile estimates and constraint identification, confirming reliable execution of all retrieval, prediction and checking steps. Conclusion: Our findings highlight the feasibility of combining structured population-based scoring with modular tool-augmented reasoning for transparent, scalable plan evaluation in radiation therapy. The system offers traceable outputs, minimizes hallucination, and demonstrates robustness across protocols. Future directions include clinician-led validation, and improved domain-adapted retrieval models to enhance real-world integration.

cs.AI

Causal Machine Learning Analysis of Empirical Relative Biological Effectiveness (RBE) for Mandible Osteoradionecrosis in Head and Neck Cancer Radiotherapy

Mandible Osteoradionecrosis (ORN) is one of the most severe adverse events (AEs) for head and neck (H&N) cancer radiotherapy. Previous retrospective investigations on real-world data relied on conventional statistical models that primarily elucidate correlation rather than establishing causal relationships. Through the novel causal machine learning, we aim to obtain empirical relative biological effectiveness (RBE) for ORN in H&N cancer patients treated with pencil-beam-scanning proton therapy (PBSPT). 335 patients treated by PBSPT and 931 patients treated by volumetric-modulated arc therapy (VMAT) were included. We use 1:1 case-matching to minimize the imbalance in clinical factors between PBSPT and VMAT. The bias test of standardized mean differences (SMD) was applied on the case-matched patient cohorts. The causal machine learning method, causal forest (CF), was adopted to investigate the causal effects between dosimetric factors and the incidence of ORN. The dose volume constraints (DVCs) for VMAT and PBSPT were derived based on causal effects. RBE values were further empirically derived based on tolerance curves formed from DVCs. 335 VMAT patients were case-matched to 335 PBSPT patients; however, SMD analysis revealed persistent covariate imbalances within each group, indicating residual confounding influence. Using CF modeling, we identified DVCs of mandible ORN and found that PBSPT had lower critical volumes than those of VMAT, leading to empirical RBE exceeding 1.1 in the moderate dose range (1.61 at 40 Gy[RBE=1.1], 1.30 at 50 Gy, and 1.13 at 60 Gy). This study presents a novel application of causal machine learning to evaluate mandible ORN in radiotherapy. The results indicate that proton RBE may significantly exceed 1.1 in the moderate dose range, underscoring the importance of incorporating the variable RBE into PBSPT treatment planning to mitigate the risk of ORN.

physics.med-ph

Diffusion Transformer-based Universal Dose Denoising for Pencil Beam Scanning Proton Therapy

Purpose: Intensity-modulated proton therapy (IMPT) offers precise tumor coverage while sparing organs at risk (OARs) in head and neck (H&N) cancer. However, its sensitivity to anatomical changes requires frequent adaptation through online adaptive radiation therapy (oART), which depends on fast, accurate dose calculation via Monte Carlo (MC) simulations. Reducing particle count accelerates MC but degrades accuracy. To address this, denoising low-statistics MC dose maps is proposed to enable fast, high-quality dose generation. Methods: We developed a diffusion transformer-based denoising framework. IMPT plans and 3D CT images from 80 H&N patients were used to generate noisy and high-statistics dose maps using MCsquare (1 min and 10 min per plan, respectively). Data were standardized into uniform chunks with zero-padding, normalized, and transformed into quasi-Gaussian distributions. Testing was done on 10 H&N, 10 lung, 10 breast, and 10 prostate cancer cases, preprocessed identically. The model was trained with noisy dose maps and CT images as input and high-statistics dose maps as ground truth, using a combined loss of mean square error (MSE), residual loss, and regional MAE (focusing on top/bottom 10% dose voxels). Performance was assessed via MAE, 3D Gamma passing rate, and DVH indices. Results: The model achieved MAEs of 0.195 (H&N), 0.120 (lung), 0.172 (breast), and 0.376 Gy[RBE] (prostate). 3D Gamma passing rates exceeded 92% (3%/2mm) across all sites. DVH indices for clinical target volumes (CTVs) and OARs closely matched the ground truth. Conclusion: A diffusion transformer-based denoising framework was developed and, though trained only on H&N data, generalizes well across multiple disease sites.

physics.med-ph

Critical review of patient outcome study in head and neck cancer radiotherapy

Rapid technological advances in radiation therapy have significantly improved dose delivery and tumor control for head and neck cancers. However, treatment-related toxicities caused by high-dose exposure to critical structures remain a significant clinical challenge, underscoring the need for accurate prediction of clinical outcomes-encompassing both tumor control and adverse events (AEs). This review critically evaluates the evolution of data-driven approaches in predicting patient outcomes in head and neck cancer patients treated with radiation therapy, from traditional dose-volume constraints to cutting-edge artificial intelligence (AI) and causal inference framework. The integration of linear energy transfer in patient outcomes study, which has uncovered critical mechanisms behind unexpected toxicity, was also introduced for proton therapy. Three transformative methodological advances are reviewed: radiomics, AI-based algorithms, and causal inference frameworks. While radiomics has enabled quantitative characterization of medical images, AI models have demonstrated superior capability than traditional models. However, the field faces significant challenges in translating statistical correlations from real-world data into interventional clinical insights. We highlight that how causal inference methods can bridge this gap by providing a rigorous framework for identifying treatment effects. Looking ahead, we envision that combining these complementary approaches, especially the interventional prediction models, will enable more personalized treatment strategies, ultimately improving both tumor control and quality of life for head and neck cancer patients treated with radiation therapy.

physics.med-ph

Fine-Tuning Open-Source Large Language Models to Improve Their Performance on Radiation Oncology Tasks: A Feasibility Study to Investigate Their Potential Clinical Applications in Radiation Oncology

Background: The radiation oncology clinical practice involves many steps relying on the dynamic interplay of abundant text data. Large language models have displayed remarkable capabilities in processing complex text information. But their direct applications in specific fields like radiation oncology remain underexplored. Purpose: This study aims to investigate whether fine-tuning LLMs with domain knowledge can improve the performance on Task (1) treatment regimen generation, Task (2) treatment modality selection (photon, proton, electron, or brachytherapy), and Task (3) ICD-10 code prediction in radiation oncology. Methods: Data for 15,724 patient cases were extracted. Cases where patients had a single diagnostic record, and a clearly identifiable primary treatment plan were selected for preprocessing and manual annotation to have 7,903 cases of the patient diagnosis, treatment plan, treatment modality, and ICD-10 code. Each case was used to construct a pair consisting of patient diagnostics details and an answer (treatment regimen, treatment modality, or ICD-10 code respectively) for the supervised fine-tuning of these three tasks. Open source LLaMA2-7B and Mistral-7B models were utilized for the fine-tuning with the Low-Rank Approximations method. Accuracy and ROUGE-1 score were reported for the fine-tuned models and original models. Clinical evaluation was performed on Task (1) by radiation oncologists, while precision, recall, and F-1 score were evaluated for Task (2) and (3). One-sided Wilcoxon signed-rank tests were used to statistically analyze the results. Results: Fine-tuned LLMs outperformed original LLMs across all tasks with p-value <= 0.001. Clinical evaluation demonstrated that over 60% of the fine-tuned LLMs-generated treatment regimens were clinically acceptable. Precision, recall, and F1-score showed improved performance of fine-tuned LLMs.

physics.med-ph

Evaluating The Performance of Using Large Language Models to Automate Summarization of CT Simulation Orders in Radiation Oncology

Purpose: This study aims to use a large language model (LLM) to automate the generation of summaries from the CT simulation orders and evaluate its performance. Materials and Methods: A total of 607 CT simulation orders for patients were collected from the Aria database at our institution. A locally hosted Llama 3.1 405B model, accessed via the Application Programming Interface (API) service, was used to extract keywords from the CT simulation orders and generate summaries. The downloaded CT simulation orders were categorized into seven groups based on treatment modalities and disease sites. For each group, a customized instruction prompt was developed collaboratively with therapists to guide the Llama 3.1 405B model in generating summaries. The ground truth for the corresponding summaries was manually derived by carefully reviewing each CT simulation order and subsequently verified by therapists. The accuracy of the LLM-generated summaries was evaluated by therapists using the verified ground truth as a reference. Results: About 98% of the LLM-generated summaries aligned with the manually generated ground truth in terms of accuracy. Our evaluations showed an improved consistency in format and enhanced readability of the LLM-generated summaries compared to the corresponding therapists-generated summaries. This automated approach demonstrated a consistent performance across all groups, regardless of modality or disease site. Conclusions: This study demonstrated the high precision and consistency of the Llama 3.1 405B model in extracting keywords and summarizing CT simulation orders, suggesting that LLMs have great potential to help with this task, reduce the workload of therapists and improve workflow efficiency.

physics.med-ph

Enabling Clinical Use of Linear Energy Transfer in Proton Therapy for Head and Neck Cancer -- A Review of Implications for Treatment Planning and Adverse Events Study

Proton therapy offers significant advantages due to its unique physical and biological properties, particularly the Bragg peak, enabling precise dose delivery to tumors while sparing healthy tissues. However, the clinical implementation is challenged by the oversimplification of the relative biological effectiveness (RBE) as a fixed value of 1.1, which does not account for the complex interplay between dose, linear energy transfer (LET), and biological endpoints. Lack of heterogeneity control or the understanding of the complex interplay may result in unexpected adverse events and suboptimal patient outcomes. On the other hand, expanding our knowledge of variable tumor RBE and LET optimization may provide a better management strategy for radioresistant tumors. This review examines recent advancements in LET calculation methods, including analytical models and Monte Carlo simulations. The integration of LET into plan evaluation is assessed to enhance plan quality control. LET-guided robust optimization demonstrates promise in minimizing high-LET exposure to organs at risk, thereby reducing the risk of adverse events. Dosimetric seed spot analysis is discussed to show its importance in revealing the true LET-related effect upon the adverse event initialization by finding the lesion origins and eliminating the confounding factors from the biological processes. Dose-LET volume histograms (DLVH) are discussed as effective tools for correlating physical dose and LET with clinical outcomes, enabling the derivation of clinically relevant dose-LET volume constraints without reliance on uncertain RBE models. Based on DLVH, the dose-LET volume constraints (DLVC)-guided robust optimization is introduced to upgrade conventional dose-volume constraints-based robust optimization, which optimizes the joint distribution of dose and LET simultaneously.

physics.med-ph

Retrospective Comparative Analysis of Prostate Cancer In-Basket Messages: Responses from Closed-Domain LLM vs. Clinical Teams

In-basket message interactions play a crucial role in physician-patient communication, occurring during all phases (pre-, during, and post) of a patient's care journey. However, responding to these patients' inquiries has become a significant burden on healthcare workflows, consuming considerable time for clinical care teams. To address this, we introduce RadOnc-GPT, a specialized Large Language Model (LLM) powered by GPT-4 that has been designed with a focus on radiotherapeutic treatment of prostate cancer with advanced prompt engineering, and specifically designed to assist in generating responses. We integrated RadOnc-GPT with patient electronic health records (EHR) from both the hospital-wide EHR database and an internal, radiation-oncology-specific database. RadOnc-GPT was evaluated on 158 previously recorded in-basket message interactions. Quantitative natural language processing (NLP) analysis and two grading studies with clinicians and nurses were used to assess RadOnc-GPT's responses. Our findings indicate that RadOnc-GPT slightly outperformed the clinical care team in "Clarity" and "Empathy," while achieving comparable scores in "Completeness" and "Correctness." RadOnc-GPT is estimated to save 5.2 minutes per message for nurses and 2.4 minutes for clinicians, from reading the inquiry to sending the response. Employing RadOnc-GPT for in-basket message draft generation has the potential to alleviate the workload of clinical care teams and reduce healthcare costs by producing high-quality, timely responses.

cs.AI

Accurate Patient Alignment without Unnecessary Imaging Dose via Synthesizing Patient-specific 3D CT Images from 2D kV Images

In radiotherapy, 2D orthogonally projected kV images are used for patient alignment when 3D-on-board imaging(OBI) unavailable. But tumor visibility is constrained due to the projection of patient's anatomy onto a 2D plane, potentially leading to substantial setup errors. In treatment room with 3D-OBI such as cone beam CT(CBCT), the field of view(FOV) of CBCT is limited with unnecessarily high imaging dose, thus unfavorable for pediatric patients. A solution to this dilemma is to reconstruct 3D CT from kV images obtained at the treatment position. Here, we propose a dual-models framework built with hierarchical ViT blocks. Unlike a proof-of-concept approach, our framework considers kV images as the solo input and can synthesize accurate, full-size 3D CT in real time(within milliseconds). We demonstrate the feasibility of the proposed approach on 10 patients with head and neck (H&N) cancer using image quality(MAE: <45HU), dosimetrical accuracy(Gamma passing rate (2%/2mm/10%)>97%) and patient position uncertainty(shift error: <0.4mm). The proposed framework can generate accurate 3D CT faithfully mirroring real-time patient position, thus significantly improving patient setup accuracy, keeping imaging dose minimum, and maintaining treatment veracity.

eess.SP

RadOnc-GPT: A Large Language Model for Radiation Oncology

This paper presents RadOnc-GPT, a large language model specialized for radiation oncology through advanced tuning methods. RadOnc-GPT was finetuned on a large dataset of radiation oncology patient records from the Mayo Clinic in Arizona. The model employs instruction tuning on three key tasks - generating radiotherapy treatment regimens, determining optimal radiation modalities, and providing diagnostic descriptions/ICD codes based on patient diagnostic details. Evaluations conducted by comparing RadOnc-GPT outputs to general large language model outputs showed higher ROUGE scores in these three tasks. The study demonstrated the potential of using large language models fine-tuned using domain-specific knowledge like RadOnc-GPT to achieve transformational capabilities in highly specialized healthcare fields such as radiation oncology. However, our model's clinical relevance requires confirmation, and it specializes in only the aforementioned three specific tasks and lacks broader applicability. Furthermore, its evaluation through ROUGE scores might not reflect the true semantic and clinical accuracy - challenges we intend to address in future research.

physics.med-ph

Modelling small block aperture in an in-house developed GPU-accelerated Monte Carlo-based dose engine for pencil beam scanning proton therapy

Purpose: To enhance an in-house graphic-processing-unit (GPU) accelerated virtual particle (VP)-based Monte Carlo (MC) proton dose engine (VPMC) to model aperture blocks in both dose calculation and optimization for pencil beam scanning proton therapy (PBSPT)-based stereotactic radiosurgery (SRS). Methods and Materials: A block aperture module was integrated into VPMC. VPMC was validated by an opensource code, MCsquare, in eight water phantom simulations with 3cm thick brass apertures: four were with aperture openings of 1, 2, 3, and 4cm without a range shifter, while the other four were with same aperture opening configurations with a range shifter of 45mm water equivalent thickness. VPMC was benchmarked with MCsquare and RayStation MC for 10 patients with small targets (average volume 8.4 cc). Finally, 3 patients were selected for robust optimization with aperture blocks using VPMC. Results: In the water phantoms, 3D gamma passing rate (2%/2mm/10%) between VPMC and MCsquare were 99.71$\pm$0.23%. In the patient geometries, 3D gamma passing rates (3%/2mm/10%) between VPMC/MCsquare and RayStation MC were 97.79$\pm$2.21%/97.78$\pm$1.97%, respectively. The calculation time was greatly decreased from 112.45$\pm$114.08 seconds (MCsquare) to 8.20$\pm$6.42 seconds (VPMC), both having statistical uncertainties of about 0.5%. The robustly optimized plans met all the dose-volume-constraints (DVCs) for the targets and OARs per our institutional protocols. The mean calculation time for 13 influence matrices in robust optimization by VPMC was 41.6 seconds. Conclusion: VPMC has been successfully enhanced to model aperture blocks in dose calculation and optimization for the PBSPT-based SRS.

physics.med-ph