SearcharxivSearch

arXiv subjects

Samuel Hedges

Publications and source records attributed to Samuel Hedges.

2 recordsLinked to original sources

Calorimetric approach to paleo-detection of dark matter

We present the first paleo-detector dark matter sensitivity analysis based on a calorimetric readout, in which the number of stable lattice vacancies produced by each nuclear recoil is used as a per-event observable complementary to the track length. Using full-cascade SRIM simulations in olivine, we compute the expected sensitivity for a 100 gGyr exposure. We find that a vacancy-only readout reaches a sensitivity envelope very similar to that of state-of-the-art track-only analyses. The combination of the two observables provides an event-by-event proxy for |dE/dx| and hence for the recoiling nuclear species. Since the neutron-nucleus cross section is approximately flat in nuclear mass while the dark-matter--nucleus cross section scales as $A^2$, this discrimination suppresses the dominant neutron background by more than an order of magnitude at moderate dark matter masses. The combined-analysis sensitivity reaches spin-independent dark-matter--nucleon cross sections of order $10^{-48}\,\mathrm{cm}^2$ at WIMP masses of a few tens of GeV, comparable to future direct detection experiments. A two-stage readout combining selective-plane illumination microscopy with scanning electron microscopy is identified as a path to making a 100 g-scale analysis plausible.

hep-ph

Measurement of the ionization yield from nuclear recoils in liquid xenon between 0.3 -- 6 keV with single-ionization-electron sensitivity

Dual-phase xenon TPC detectors are a highly scalable and widely used technology to search for low-energy nuclear recoil signals from WIMP dark matter or coherent nuclear scattering of $\sim$MeV neutrinos. Such experiments expect to measure O(keV) ionization or scintillation signals from such sources. However, at $\sim1\,$keV and below, the signal calibrations in liquid xenon carry large uncertainties that directly impact the assumed sensitivity of existing and future experiments. In this work, we report a new measurement of the ionization yield of nuclear recoil signals in liquid xenon down to 0.3$\,$keV$\,\,$-- the lowest energy calibration reported to date -- at which energy the average event produces just 1.1~ionized~electrons. Between 2 and 6$\,$keV, our measurements agree with existing measurements, but significantly improve the precision. At lower energies, we observe a decreasing trend that deviates from simple extrapolations of existing data. We also study the dependence of ionization yield on the applied drift field in liquid xenon between 220V/cm and 6240V/cm, allowing these measurements to apply to a broad range of current and proposed experiments with different operating parameters.

physics.ins-det