Searcharxiv⌕ Search

arXiv subjects

Sang-Sung Lee

Publications and source records attributed to Sang-Sung Lee.

105 records · Page 6Linked to original sources

Interferometric Monitoring of Gamma-ray Bright Active Galactic Nuclei II: Frequency Phase Transfer

The Interferometric Monitoring of Gamma-ray Bright Active galactic nuclei (iMOGABA) program provides not only simultaneous multifrequency observations of bright gamma-ray detected active galactic nuclei (AGN), but also covers the highest Very Large Baseline Interferometry (VLBI) frequencies ever being systematically monitored, up to 129 GHz. However, observation and imaging of weak sources at the highest observed frequencies is very challenging. In the second paper in this series, we evaluate the viability of the frequency phase transfer technique to iMOGABA in order to obtain larger coherence time at the higher frequencies of this program (86 and 129 GHz) and image additional sources that were not detected using standard techniques. We find that this method is applicable to the iMOGABA program even under non-optimal weather conditions.

astro-ph.IM↗

Amplitude Correction Factors of KVN Observations

We report results of investigation of amplitude calibration for very long baseline interferometry (VLBI) observations with Korean VLBI Network (KVN). Amplitude correction factors are estimated based on comparison of KVN observations at 22~GHz correlated by Daejeon hardware correlator and DiFX software correlator in Korea Astronomy and Space Science Institute (KASI) with Very Long Baseline Array (VLBA) observations at 22~GHz by DiFX software correlator in National Radio Astronomy Observatory (NRAO). We used the observations for compact radio sources, 3C 454.3, NRAO 512, OJ 287, BL Lac, 3C 279, 1633+382, and 1510-089, which are almost unresolved for baselines in a range of 350-477 km. Visibility data of the sources obtained with similar baselines at KVN and VLBA are selected, fringe-fitted, calibrated, and compared for their amplitudes. We found that visibility amplitudes of KVN observations should be corrected by factors of 1.10 and 1.35 when correlated by DiFX and Daejeon correlators, respectively. These correction factors are attributed to the combination of two steps of 2-bit quantization in KVN observing systems and characteristics of Daejeon correlator.

astro-ph.IM↗

First Detection of 350 Micron Polarization From a Radio-loud AGN

We report the first detection of linearly polarized emission at an observing wavelength of 350 $μ$m from the radio-loud Active Galactic Nucleus 3C 279. We conducted polarization observations for 3C 279 using the SHARP polarimeter in the Caltech Submillimeter Observatory on 2014 March 13 and 14. For the first time, we detected the linear polarization with the degree of polarization of 13.3\%$\pm$3.4\% ($3.9σ$) and the Electric Vector Position Angle (EVPA) of 34.7$^\circ\pm5.6^\circ$. We also observed 3C~279 simultaneously at 13, 7, and 3.5 mm in dual polarization with the Korean very long baseline interferometry (VLBI) Network on 2014 March 6 (single dish) and imaged in milliarcsecond (mas) scales at 13, 7, 3.5, and 2.3 mm on March 22 (VLBI). We found that the degree of linear polarization increases from 10\% to 13\% at 13 mm to 350 $μ$m and the EVPAs at all observing frequencies are parallel within $<10^\circ$ to the direction of the jet at mas scale, implying that the integrated magnetic fields are perpendicular to the jet in the innermost regions. We also found that the Faraday rotation measures RM are in a range of $-6.5\times10^2 \sim -2.7\times10^3$ rad m$^{-2}$ between 13 and 3.5 mm, and are scaled as a function of wavelength: $|{\rm RM}|\proptoλ^{-2.2}$. These results indicate that the mm and sub-mm polarization emission are generated in the compact jet within 1~mas scale and affected by a Faraday screen in or in the close proximity of the jet.

astro-ph.GA↗

The Nuclear Structure of 3C84 with Space VLBI (RadioAstron) Observations

The radio galaxy 3C84 is a representative of gamma-ray-bright misaligned active galactic nuclei (AGN) and one of the best laboratories to study the radio properties of subparsec scale jets. We discuss here the past and present activity of the nuclear region within the central 1pc and the properties of subparsec-sized components C1, C2 and C3. We compare these results with the high resolution space-VLBI image at 5GHz obtained with the RadioAstron satellite and we shortly discuss the possible correlation of radio emission with the gamma-ray emission.

astro-ph.HE↗

A New Hardware Correlator in Korea: Performance Evaluation using KVN observations

We report results of the performance evaluation of a new hardware correlator in Korea, the Daejeon correlator, developed by the Korea Astronomy and Space Science Institute (KASI) and the National Astronomical Observatory of Japan (NAOJ). We conducted Very Long Baseline Interferometry (VLBI) observations at 22~GHz with the Korean VLBI Network (KVN) in Korea and the VLBI Exploration of Radio Astrometry (VERA) in Japan, and correlated the aquired data with the Daejeon correlator. For evaluating the performance of the new hardware correlator, we compared the correlation outputs from the Daejeon correlator for KVN observations with those from a software correlator, the Distributed FX (DiFX). We investigated the correlated flux densities and brightness distributions of extragalactic compact radio sources. The comparison of the two correlator outputs show that they are consistent with each other within $<8\%$, which is comparable with the amplitude calibration uncertainties of KVN observations at 22~GHz. We also found that the 8\% difference in flux density is caused mainly by (a) the difference in the way of fringe phase tracking between the DiFX software correlator and the Daejeon hardware correlator, and (b) an unusual pattern (a double-layer pattern) of the amplitude correlation output from the Daejeon correlator. The visibility amplitude loss by the double-layer pattern is as small as 3\%. We conclude that the new hardware correlator produces reasonable correlation outputs for continuum observations, which are consistent with the outputs from the DiFX software correlator.

astro-ph.IM↗

Intrinsic Brightness Temperatures of Compact Radio Jets as a Function of Frequency

We present results of our investigation of the radio intrinsic brightness temperatures of compact radio jets. The intrinsic brightness temperatures of about 100 compact radio jets at 2, 5, 8, 15, and 86 GHz are estimated based on large VLBI surveys conducted in 2001-2003 (or in 1996 for the 5 GHz sample). The multi-frequency intrinsic brightness temperatures of the sample of jets are determined by a statistical method relating the observed brightness temperatures with the maximal apparent jet speeds, assuming one representative intrinsic brightness temperature for a sample of jets at each observing frequency. By investigating the observed brightness temperatures at 15 GHz in multiple epochs, we found that the determination of the intrinsic brightness temperature for our sample is affected by the flux density variability of individual jets at time scales of a few years. This implies that it is important to use contemporaneous VLBI observations for the multi-frequency analysis of intrinsic brightness temperatures. Since our analysis is based on the VLBI observations conducted in 2001-2003, the results are not strongly affected by the flux density variability. We found that the intrinsic brightness temperature $T_{\rm 0}$ increases as $T_{\rm 0}\proptoν_{\rm obs}^ξ$ with $ξ=0.7$ below a critical frequency $ν_{\rm c}\approx9 {\rm GHz}$ where energy losses begin to dominate the emission. Above $ν_{\rm c}$, $T_{\rm 0}$ decreases with $ξ=-1.2$, supporting for the decelerating jet model or particle cascade model. We also found that the peak value of $T_{\rm 0}\approx3.4\times10^{10}$ K is close to the equipartition temperature, implying that the VLBI cores observable at 2-86 GHz may be representing jet regions where the magnetic field energy dominates the total energy in jets.

astro-ph.GA↗

Astrometrically Registered Simultaneous Observations of the 22 GHz H$_2$O and the 43GHz SiO masers towards R Leonis Minoris using KVN and Source/Frequency Phase Referencing

Oxygen-rich Asymptotic Giant Branch (AGB) stars can be intense emitters of SiO ($v$=1 and 2, J=1$\rightarrow$0) and H$_2$O maser lines at 43 and 22 GHz, respectively. VLBI observations of the maser emission provide a unique tool to probe the innermost layers of the circumstellar envelopes in AGB stars. Nevertheless, the difficulties in achieving astrometrically aligned \water\ and $v$=1 and $v$=2 SiO maser maps have traditionally limited the physical constraints that can be placed on the SiO maser pumping mechanism. We present phase referenced simultaneous spectral-line VLBI images for the SiO $v$=1 and $v$=2, J=1$\rightarrow$0, and H$_2$O maser emission around the AGB star R\,LMi, obtained from the Korean VLBI Network (KVN). The simultaneous multi-channel receivers of the KVN offer great possibilities for astrometry in the frequency domain. With this facility we have produced images with bona-fide absolute astrometric registration between high frequency maser transitions of different species to provide the positions of the \water\ maser emission, and the centre of the SiO maser emission, and hence reducing the uncertainty in the proper motion for R\,LMi by an order of magnitude over that from Hipparcos. This is the first successful demonstration of source frequency phase referencing for mm-VLBI spectral-line observations and also where the ratio between the frequencies is not an integer.

astro-ph.IM↗

Verification of the Astrometric Performance of the Korean VLBI Network, using comparative SFPR studies with the VLBA at 14/7 mm

The Korean VLBI Network (KVN) is a new mm-VLBI dedicated array with capability for simultaneous observations at multiple frequencies, up to 129 GHz. The innovative multi-channel receivers present significant benefits for astrometric measurements in the frequency domain. The aim of this work is to verify the astrometric performance of the KVN using a comparative study with the VLBA, a well established instrument. For that purpose, we carried out nearly contemporaneous observations with the KVN and the VLBA, at 14/7 mm, in April 2013. The KVN observations consisted of simultaneous dual frequency observations, while the VLBA used fast frequency switching observations. We used the Source Frequency Phase Referencing technique for the observational and analysis strategy. We find that having simultaneous observations results in a superior performance for compensation of all atmospheric terms in the observables, in addition to offering other significant benefits for astrometric analysis. We have compared the KVN astrometry measurements to those from the VLBA. We find that the structure blending effects introduce dominant systematic astrometric shifts and these need to be taken into account. We have tested multiple analytical routes to characterize the impact of the low resolution effects for extended sources in the astrometric measurements. The results from the analysis of KVN and full VLBA datasets agree within 2-$σ$ of the thermal error estimate. We interpret the discrepancy as arising from the different resolutions. We find that the KVN provides astrometric results with excellent agreement, within 1-$σ$, when compared to a VLBA configuration which has a similar resolution. Therefore this comparative study verifies the astrometric performance of KVN using SFPR at 14/7 mm, and validates the KVN as an astrometric instrument.

astro-ph.IM↗

VLBI observations of bright AGN jets with KVN and VERA Array (KaVA): Evaluation of Imaging Capability

The Korean very-long-baseline interferometry (VLBI) network (KVN) and VLBI Exploration of Radio Astrometry (VERA) Array (KaVA) is the first international VLBI array dedicated to high-frequency (23 and 43 GHz bands) observations in East Asia. Here, we report the first imaging observations of three bright active galactic nuclei (AGNs) known for their complex morphologies: 4C 39.25, 3C 273, and M 87. This is one of the initial result of KaVA early science. Our KaVA images reveal extended outflows with complex substructure such as knots and limb brightening, in agreement with previous Very Long Baseline Array (VLBA) observations. Angular resolutions are better than 1.4 and 0.8 milliarcsecond at 23 GHz and 43 GHz, respectively. KaVA achieves a high dynamic range of ~1000, more than three times the value achieved by VERA. We conclude that KaVA is a powerful array with a great potential for the study of AGN outflows, at least comparable to the best existing radio interferometric arrays.

astro-ph.IM↗

The First Very Long Baseline Interferometry Image of 44 GHz Methanol Maser with the KVN and VERA Array (KaVA)

We have carried out the first very long baseline interferometry (VLBI) imaging of 44 GHz class I methanol maser (7_{0}-6_{1}A^{+}) associated with a millimeter core MM2 in a massive star-forming region IRAS 18151-1208 with KaVA (KVN and VERA Array), which is a newly combined array of KVN (Korean VLBI Network) and VERA (VLBI Exploration of Radio Astrometry). We have succeeded in imaging compact maser features with a synthesized beam size of 2.7 milliarcseconds x 1.5 milliarcseconds (mas). These features are detected at a limited number of baselines within the length of shorter than approximately 650 km corresponding to 100 Mlambda in the uv-coverage. The central velocity and the velocity width of the 44 GHz methanol maser are consistent with those of the quiescent gas rather than the outflow traced by the SiO thermal line. The minimum component size among the maser features is ~ 5 mas x 2 mas, which corresponds to the linear size of ~ 15 AU x 6 AU assuming a distance of 3 kpc. The brightness temperatures of these features range from ~ 3.5 x 10^{8} to 1.0 x 10^{10} K, which are higher than estimated lower limit from a previous Very Large Array observation with the highest spatial resolution of ~ 50 mas. The 44 GHz class I methanol maser in IRAS 18151-1208 is found to be associated with the MM2 core, which is thought to be less evolved than another millimeter core MM1 associated with the 6.7 GHz class II methanol maser.

astro-ph.GA↗

Intrinsic Brightness Temperature of Compact Radio Sources at 86 GHz

We present results on the intrinsic brightness temperature of a sample of compact radio sources observed at 86 GHz using the Global Millimeter VLBI Array. We use the observed brightness temperatures at 86 GHz and the observed superluminal motions at 15 GHz for the sample in order to constrain the characteristic intrinsic brightness temperature of the sample. With a statistical method for studying the intrinsic brightness temperatures of innermost jet cores of compact radio sources, assuming that all sources have the same intrinsic brightness temperature and the viewing angles of their jets are around the critical value for the maximal apparent speed, we find that sources in the sample have a characteristic intrinsic brightness temperature, $T_{\rm 0} = 4.8^{+2.6}_{-1.5}\times 10^{9}$ K, which is lower than the equipartition temperature for the condition that the particle energy equals to the magnetic field energy. Our results suggest that the VLBI cores seen at 86 GHz may be representing a jet region where the magnetic field energy dominates the total energy in the jet.

astro-ph.HE↗

Monitoring of multi-frequency polarization of gamma-ray bright AGNs

We started two observing programs with the Korean VLBI Network (KVN) monitoring changes in the flux density and polarization of relativistic jets in gamma-ray bright AGNs simultaneously at 22, 43, 86, 129 GHz. One is a single-dish weekly-observing program in dual polarization with KVN 21-m diameter radio telescopes beginning in 2011 May. The other is a VLBI monthly-observing program with the three-element VLBI network at an angular resolution range of 1.0--9.2 mas beginning in 2012 December. The monitoring observations aim to study correlation of variability in gamma-ray with that in radio flux density and polarization of relativistic jets when they flare up. These observations enable us to study the origin of the gamma-ray flares of AGNs.

astro-ph.HE↗

Early science with Korean VLBI network: the QCAL-1 43GHz calibrator survey

This paper presents the catalog of correlated flux densities in three ranges of baseline projection lengths of 637 sources from a 43 GHz (Q-band) survey observed with the Korean VLBI Network. Of them, 623 sources have not been observed before at Q-band with VLBI. The goal of this work in the early science phase of the new VLBI array is twofold: to evaluate the performance of the new instrument that operates in a frequency range of 22-129 GHz and to build a list of objects that can be used as targets and as calibrators. We have observed the list of 799 target sources with declinations down to -40 degrees. Among them, 724 were observed before with VLBI at 22 GHz and had correlated flux densities greater than 200 mJy. The overall detection rate is 78%. The detection limit, defined as the minimum flux density for a source to be detected with 90% probability in a single observation, was in a range of 115-180 mJy depending on declination. However, some sources as weak as 70 mJy have been detected. Of 623 detected sources, 33 objects are detected for the first time in VLBI mode. We determined their coordinates with the median formal uncertainty 20 mas. The results of this work set the basis for future efforts to build the complete flux-limited sample of extragalactic sources at frequencies 22 GHz and higher at 3/4 of the celestial sphere.

astro-ph.IM↗

Single dish performance of KVN 21-m radio telescopes:Simultaneous observations at 22 and 43 GHz

We report simultaneous multi-frequency observing performance at 22 and 43 GHz of the 21-m shaped-Cassegrain radio telescopes of the Korean VLBI Network (KVN). KVN is the first millimeter-dedicated VLBI network in Korea having a maximum baseline length of 480 km. It currently operates at 22 and 43 GHz and planed to operate in four frequency bands, 22, 43, 86, and 129 GHz. The unique quasioptics of KVN enable simultaneous multi-frequency observations based on efficient beam filtering and accuarate antenna-beam alignment at 22 and 43 GHz. We found that the offset of the beams is within <5 arcseconds over all pointing directions of antenna. The dual polarization, cooled HEMT receivers at 22 and 43 GHz result in receiver noise temperatures less than 40 K at 21.25-23.25 GHz and 80 K at 42.11-44.11 GHz. The pointing accuracies have been measured to be 3 arcseconds in azimuth and elevation for all antennas. The measured aperture efficiencies are 65%(K)/67%(Q), 62%(K)/59%(Q), and 66%(K)/60%(Q) for the three KVN antennas, KVNYS, KVNUS, and KVNTN, respectively. The main-beam efficiencies are measured to be 50%(K)/52%(Q), 48%(K)/50%(Q), and 50%(K)/47%(Q) for KVNYS, KVNUS, and KVNTN, respectively. The estimated Moon efficiencies are 77%(K)/90%(Q), 74%(K)/79%(Q), and 80%(K)/86%(Q) for KVNYS, KVNUS, KVNTN, respectively. The elevation dependence of the aperture efficiencies is quite flat for elevations > 20 degrees.

astro-ph.IM↗

A Global 86GHz VLBI Survey of Compact Radio Sources

We present results from a large 86GHz global VLBI survey of compact radio sources. The main goal of the survey is to increase by factors of 3--5 the total number of objects accessible for future 3-mm VLBI imaging. The survey observations reach the baseline sensitivity of 0.1Jy and image sensitivity of better than 10 mJy/beam. The total of 127 compact radio sources have been observed. The observations have yielded images for 109 sources, extending the database of the sources imaged at 86GHz with VLBI observation by a factor of 5, and only 6 sources have not been detected. The remaining 12 objects have been detected but could not be imaged due to insufficient closure phase information. Radio galaxies are less compact than quasars and BL Lacs on sub-milliarcsecond scale. Flux densities and sizes of core and jet components of all imaged sources have been estimated using Gaussian model fitting. From these measurements, brightness temperatures have been calculated, taking into account resolution limits of the data. The cores of 70% of the imaged sources are resolved. The core brightness temperatures of the sources peak at $\sim 10^{11}$ K and only 1% have brightness temperatures higher than $10^{12}$ K. Cores of Intraday Variable (IDV) sources are smaller in angular size than non-IDV sources, and so yield higher brightness temperatures.

astro-ph↗