Real-time feedback control of ELM frequency using divertor gas puffing and its effects on tungsten-induced radiation and plasma performance in KSTAR

The edge-localized mode (ELM) frequency ($f_{\mathrm{ELM}}$) was successfully controlled in real time on KSTAR using a proportional-integral (PI) feedback controller, employing a $\mathrm{D}_2$ divertor gas puff as the actuator under tungsten lower-divertor conditions. The controller accurately tracked a two-step target---a 30 Hz increase in $f_{\mathrm{ELM}}$ for 4 s, followed by a 30 Hz decrease for 3 s---yielding mean and median absolute percentage errors of approximately 13% and 12%, respectively. Compared to a reference discharge, the actively controlled shot did not exhibit a significant drop in volume-integrated core radiation, confirming that excessive gas use merely degrades overall plasma performance. However, when contrasted with the exponential increase in core radiation observed in the absence of divertor gas puffing, these results underscore the critical need for real-time optimization. Specifically, divertor gas commands must be actively managed to maintain an $f_{\mathrm{ELM}}$ sufficient for flushing tungsten from the core while maximizing global plasma performance.

physics.plasm-ph

Automated Outlier-Robust Bayesian Profile Fitting for Magnetically Confined Plasmas with Modified Tanh Profiles and Good-and-Bad Gaussian Mixture Likelihoods

We present an outlier-robust Bayesian approach for automated kinetic profile fitting in magnetically confined plasmas with the modified tanh (mtanh) parametrisation and demonstrate its implementation on KSTAR. The method addresses two systematic obstacles: anomalous diagnostic channels can bias least-squares fits, and multimodality of the mtanh cost surface can trap deterministic optimisers in secondary minima. The deployed workflow uses a good-and-bad Gaussian mixture likelihood based on the Box--Tiao formulation as the default outlier-robust likelihood for fitted diagnostic channels, with posterior outlier probabilities retained as channel-level quality indicators. The posterior is sampled with an affine-invariant ensemble MCMC sampler initialised near the result of deterministic maximum a posteriori (MAP)-seeking optimisation, reducing sensitivity to secondary minima on the multimodal mtanh surface. A batch automation layer retrieves diagnostic data from MDSplus and fits arbitrary time slices in parallel for the quantities \(n_e\), \(T_e\), \(T_i\), and \(v_T\) for which the relevant diagnostics are available. Results are written in formats suitable for MDSplus upload and downstream analysis. Representative KSTAR H-mode cases show that the mixture likelihood downweights contaminated measurements while preserving plausible pedestal profiles. The workflow provides a practical basis for future large-scale kinetic profile production for kinetic-EFIT, TRANSP, FASTRAN, and data-driven analysis workflows.

physics.plasm-ph

Control of pedestal-top electron density using RMP and gas puff at KSTAR

We report the experimental results of controlling the pedestal-top electron density by applying resonant magnetic perturbation with the in-vessel control coils and the main gas puff in the 2024-2025 KSTAR experimental campaign. The density is reconstructed using a parametrized psi_N grid and the five channels of the line-averaged density measured by a two-colored interferometer. The reconstruction procedure is accelerated by deploying a multi-layer perceptron to run in about 120 microseconds and is fast enough for real-time control. A proportional-integration controller is adopted, with the controller gains being estimated from the system identification processes. The experimental results show that the developed controller can follow a dynamic target while exclusively using both actuators. The absolute percentage errors between the electron density at psi_N=0.89 and the target are approximately 1.5% median and a 2.5% average value. The developed controller can even lower the density by using the pump-out mechanism under RMP, and it can follow a more dynamic target than a single actuator controller. The developed controller will enable experimental scenario exploration within a shot by dynamically setting the density target or maintaining a constant electron density within a discharge.