Realistic noise synthesis reduces bias and improves tissue microstructure estimation with supervised machine learning

Diffusion MRI enables non-invasive probing of tissue microstructure, but accurate parameter estimation is challenged by noise-related effects. In supervised machine learning frameworks trained on simulated data, discrepancies between the noise characteristics of simulated and acquired signals introduce a form of covariate shift, whereby the input signal distribution differs between training and inference. We investigated the impact of this mismatch on microstructure parameter estimation and propose a realistic noise synthesis (RNS) framework to mitigate it. RNS incorporates both the Rician expectation and the effective post-processing noise variance into simulated training signals. The Rician expectation was modelled using a noise standard deviation estimated with MPPCA, while the effective standard deviation was derived from spherical harmonic residuals of preprocessed data. The method was evaluated using the cylinder-zeppelin and the SANDI models on simulated datasets across multiple SNR levels and on in vivo diffusion data with repeated acquisitions. Sensitivity to noise misestimation was also assessed. Ignoring magnitude-induced noise effects during training produced systematic, SNR-dependent parameter bias, particularly at low SNR. Incorporating the Rician expectation substantially reduced bias to the level of noise-aware nonlinear least-squares fitting. Modelling the effective standard deviation further improved precision. Performance was largely independent of regression architecture but sensitive to accurate noise estimation. These findings demonstrate that realistic noise modelling in simulated training data mitigates signal-domain covariate shift and is essential for unbiased supervised microstructure estimation, particularly in low-SNR regimes associated with high b-values or high spatial resolution.

cs.LG↗

MICCAI-CDMRI 2023 QuantConn Challenge Findings on Achieving Robust Quantitative Connectivity through Harmonized Preprocessing of Diffusion MRI

White matter alterations are increasingly implicated in neurological diseases and their progression. International-scale studies use diffusion-weighted magnetic resonance imaging (DW-MRI) to qualitatively identify changes in white matter microstructure and connectivity. Yet, quantitative analysis of DW-MRI data is hindered by inconsistencies stemming from varying acquisition protocols. There is a pressing need to harmonize the preprocessing of DW-MRI datasets to ensure the derivation of robust quantitative diffusion metrics across acquisitions. In the MICCAI-CDMRI 2023 QuantConn challenge, participants were provided raw data from the same individuals collected on the same scanner but with two different acquisitions and tasked with preprocessing the DW-MRI to minimize acquisition differences while retaining biological variation. Submissions are evaluated on the reproducibility and comparability of cross-acquisition bundle-wise microstructure measures, bundle shape features, and connectomics. The key innovations of the QuantConn challenge are that (1) we assess bundles and tractography in the context of harmonization for the first time, (2) we assess connectomics in the context of harmonization for the first time, and (3) we have 10x additional subjects over prior harmonization challenge, MUSHAC and 100x over SuperMUDI. We find that bundle surface area, fractional anisotropy, connectome assortativity, betweenness centrality, edge count, modularity, nodal strength, and participation coefficient measures are most biased by acquisition and that machine learning voxel-wise correction, RISH mapping, and NeSH methods effectively reduce these biases. In addition, microstructure measures AD, MD, RD, bundle length, connectome density, efficiency, and path length are least biased by these acquisition differences.

physics.med-ph↗

Computation of Exact g-Factor Maps in 3D GRAPPA Reconstructions

Purpose: To characterize the noise distributions in 3D-MRI accelerated acquisitions reconstructed with GRAPPA using an exact noise propagation analysis that operates directly in k--space. Theory and Methods: We exploit the extensive symmetries and separability in the reconstruction steps to account for the correlation between all the acquired k-space samples. Monte Carlo simulations and multi-repetition phantom experiments were conducted to test both the accuracy and feasibility of the proposed method; an in-vivo experiment was performed to assess the applicability of our method to clinical scenarios. Results: Our theoretical derivation shows that the direct k-space analysis renders an exact noise characterization under the assumptions of stationarity and uncorrelation in the original k-space. Simulations and phantom experiments provide empirical support to the theoretical proof. Finally, the in-vivo experiment demonstrates the ability of the proposed method to assess the impact of the sub-sampling pattern on the overall noise behavior. Conclusions: By operating directly in the k-space, the proposed method is able to provide an exact characterization of noise for any Cartesian pattern sub-sampled along the two phase-encoding directions. Exploitation of the symmetries and separability into independent blocks through the image reconstruction procedure allows us to overcome the computational challenges related to the very large size of the covariance matrices involved.

physics.med-ph↗

Exact Calculation of Noise Maps and g-Factor in GRAPPA using a k-space Analysis

Noise characterization in MRI has multiple applications, including quality assurance and protocol optimization. It is particularly important in the presence of parallel imaging acceleration, where the noise distribution can contain severe spatial heterogeneities. If the parallel imaging reconstruction is a linear process, an exact noise analysis is possible by taking into account the correlations between all the samples involved. However, for k-space based techniques like GRAPPA, the exact analysis has been considered computationally prohibitive due to the very large size of the noise covariance matrices required to characterize the noise propagation from k-space to image-space. Previous methods avoid this computational burden by approximating the GRAPPA reconstruction as a pixel-wise linear operation performed in the image-space. However, these methods are not exact in the presence of non-uniform k-space undersampling (e.g.: containing a calibration region). For this reason, in this work we develop an exact characterization of the noise distribution for self-calibrated parallel imaging in the presence of arbitrary Cartesian undersampling patterns. By exploiting the symmetries and separability in the noise propagation process, the proposed method is computationally efficient and does not require large matrices. In this manuscript, we present the proposed noise characterization method and compare it to previous techniques using Monte-Carlo simulations as well as phantom acquisitions.

physics.med-ph↗

Spherical deconvolution of multichannel diffusion MRI data with non-Gaussian noise models and spatial regularization

Spherical deconvolution (SD) methods are widely used to estimate the intra-voxel white-matter fiber orientations from diffusion MRI data. However, while some of these methods assume a zero-mean Gaussian distribution for the underlying noise, its real distribution is known to be non-Gaussian and to depend on the methodology used to combine multichannel signals. Indeed, the two prevailing methods for multichannel signal combination lead to Rician and noncentral Chi noise distributions. Here we develop a Robust and Unbiased Model-BAsed Spherical Deconvolution (RUMBA-SD) technique, intended to deal with realistic MRI noise, based on a Richardson-Lucy (RL) algorithm adapted to Rician and noncentral Chi likelihood models. To quantify the benefits of using proper noise models, RUMBA-SD was compared with dRL-SD, a well-established method based on the RL algorithm for Gaussian noise. Another aim of the study was to quantify the impact of including a total variation (TV) spatial regularization term in the estimation framework. To do this, we developed TV spatially-regularized versions of both RUMBA-SD and dRL-SD algorithms. The evaluation was performed by comparing various quality metrics on 132 three-dimensional synthetic phantoms involving different inter-fiber angles and volume fractions, which were contaminated with noise mimicking patterns generated by data processing in multichannel scanners. The results demonstrate that the inclusion of proper likelihood models leads to an increased ability to resolve fiber crossings with smaller inter-fiber angles and to better detect non-dominant fibers. The inclusion of TV regularization dramatically improved the resolution power of both techniques. The above findings were also verified in brain data.