SearcharxivSearch

arXiv subjects

Satoshi Higashino

Publications and source records attributed to Satoshi Higashino.

8 recordsLinked to original sources

Measurement of ionization yield of low energy ions in low pressure $\mathrm{CF}_{4}$ gas for dark matter searches

Direction-sensitive direct dark matter search experiments have been conducted using gaseous detectors. In spite of the long history of the study on the energy deposition of charged particles in materials, a full agreement between the measured results and theoretical predictions, especially in a low energy scale, are yet to be achieved. It is thus important to measure the ionization yields of recoil nuclei for the experiments with gaseous detectors using an ionization charge readout scheme. This study measured the ionization yield using a low-energy ion beam facility at Kanagawa University. The ionization yields for fluorine ions with an energy range of 5 $\sim$ 50 keV were measured using a dedicated proportional wire chamber filled with $\mathrm{CF}_{4}$ gas at 0.06 atm. The low-energy ion injection scheme into a gaseous detector was established and the ionization yield for fluorine ions was obtained to be 0.45 at 30 keV with a moderate dependence on the ion energy.

physics.ins-det

Development of a low-background micro pixel chamber for directional dark matter searches

Direct detection of weakly interacting massive particles (WIMPs) can provide strong evidence of their existence and the directional method would have an advantage over other methods to detect the clear signal of WIMPs. Time projection chambers with micro-patterned gaseous detectors (MPGDs) are one of the common devices used in directional WIMP searches. A micro pixel chamber ($μ$-PIC), one of the various types of MPGDs, with specially selected low background materials (LBG$μ$-PIC) was developed and its performance was studied. The radon emission of the LBG$μ$-PIC was less than 1/60 of that of the $μ$-PIC currently in use. Although a non-negligible gain non-homogeneity was seen for the LBG$μ$-PIC, it can be used for the directional WIMP search with the correction of the non-homogeneity.

physics.ins-det

Direction-sensitive dark matter search with three-dimensional vector-type tracking in NEWAGE

NEWAGE is a direction-sensitive dark matter search experiment with a three-dimensional tracking detector based on a gaseous micro time projection chamber. A direction-sensitive dark matter search was carried out at Kamioka Observatory with a total live time of 318.0 days resulting in an exposure of 3.18 kg$\cdot$days. A new gamma-ray rejection and a head-tail determination analysis were implemented for this work. No significant non-isotropic signal from the directional analysis was found and a 90% confidence level upper limit on spin-dependent WIMP-proton cross section of 25.7 pb for WIMP mass of 150 GeV/c2 was derived. This upper limit is the most stringent in the direction-sensitive dark matter searches.

hep-ex

Directional direct detection of light dark matter up-scattered by cosmic rays from direction of the Galactic center

Dark matter with MeV scale mass is difficult to detect with standard direct search detectors. However, they can be searched for by considering the up-scattering of kinetic energies by cosmic rays. Because the dark matter density is higher in the central region of the Galaxy, the up-scattered dark matter will arrive at Earth from the direction of the Galactic center. Once the dark matter is detected, we can expect to recognize this feature by directional direct detection experiments. In this study, we simulate the nuclear recoils of the up-scattered dark matter and quantitatively reveal that a large amount of this type of dark matter is arriving from the direction of the Galactic center. Also, we have shown that the characteristic signatures of the up-scattered dark matter can be verified with more than 5$σ$ confidence levels for the assumed target atoms and future upgrades to directional detectors.

astro-ph.CO

First reconstruction of absolute three-dimensional position of nuclear recoils using a negative ion $μ$-TPC for dark matter search experiments

Studies of micro time projection chambers using negative ion gas (NI$μ$TPC) are conducted especially for direction-sensitive dark matter searches. A NI$μ$TPC enables to measure the absolute position in the drift direction for self-triggering TPCs. This study provides a development of a NI$μ$TPC using a micro pixel chamber ($μ$-PIC) with dedicated readout electronics, and an evaluation of the capability of three-dimensional absolute position reconstruction of nuclear recoil using a neutron source. The absolute track position was reconstructed throughout the drift volume with an efficiency of 70$\pm$5%. This work marks an important step for the NI$μ$TPCs towards the practical use for directional dark matter searches.

physics.ins-det

Scintillation light increase of carbontetrafluoride gas at low temperature

Scintillation detector is widely used for the particle detection in the field of particle physics. Particle detectors containing fluorine-19 ($^{19}\mathrm{F}$) are known to have advantages for Weakly Interacting Massive Particles (WIMPs) dark matter search, especially for spin-dependent interactions with WIMPs due to its spin structure. In this study, the scintillation properties of carbontetrafluoride ($\mathrm{CF_{4}}$) gas at low temperature was evaluated because its temperature dependence of light yield has not been measured. We evaluated the light yield by cooling the gas from room temperature (300K) to 263K. As a result, the light yield of $\mathrm{CF_{4}}$ was found to increase by $(41.0\pm4.0_{\rm stat.}\pm6.6_{\rm syst.})\%$ and the energy resolution was also found to improve at low temperature.

physics.ins-det

Weak Value Amplification in High Energy Physics: A Case Study for Precision Measurement of CP Violation in B Meson Decays

The technique of weak value amplification, proposed by Aharonov et al. in 1988, has been applied for various fields of physics for the purpose of precision measurement, which is made possible by exploiting the freedom of `postselection' specifying actively the final state in the physical process. Here we report for the first time the feasibility of utilizing the technique of weak value amplification in high energy particle physics, especially in measuring the CP-violating parameters in B meson decays, where the effective lifetime of the decay mode is expected to be prolonged statistically due to the postselection. Our analysis shows that, when adopted in the Belle II experiment at the SuperKEKB collider, the effective lifetime may be prolonged up to 2.6 times, and that the measurement precision of the CP-violating parameters will also be improved by its effect.

quant-ph

On the Feasibility of Bell Inequality Violation at ATLAS Experiment with Flavor Entanglement of $B^{0}\bar{B}^{0}$ Pairs from $pp$ Collisions

We examine the feasibility of the Bell test (i.e., detecting a violation of the Bell inequality) with the ATLAS detector in Large Hadron Collider (LHC) at CERN through the flavor entanglement between the B mesons. After addressing the possible issues that arise associated with the experiment and how they may be treated based on an analogy with conventional Bell tests, we show in our simulation study that under realistic conditions (expected from the LHC Run 3 operation) the Bell test is feasible under mild assumptions. The definitive factor for this promising result lies primarily in the fact that the ATLAS detector is capable of measuring the decay times of the B mesons independently, which was not available in the previous experiment with the Belle detector at KEK. This result suggests the possibility of the Bell test in much higher energy domains and may open up a new arena for experimental studies of quantum foundations.

hep-ph