SearcharxivSearch

arXiv subjects

Satrajit Chakrabarty

Publications and source records attributed to Satrajit Chakrabarty.

12 recordsLinked to original sources

Synthetic Volumetric Data Generation Enables Zero-Shot Generalization of Foundation Models in 3D Medical Image Segmentation

Foundation models such as Segment Anything Model 2 (SAM 2) exhibit strong generalization on natural images and videos but perform poorly on medical data due to differences in appearance statistics, imaging physics, and three-dimensional structure. To address this gap, we introduce SynthFM-3D, an analytical framework that mathematically models 3D variability in anatomy, contrast, boundary definition, and noise to generate synthetic data for training promptable segmentation models without real annotations. We fine-tuned SAM 2 on 10,000 SynthFM-3D volumes and evaluated it on eleven anatomical structures across three medical imaging modalities (CT, MR, ultrasound) from five public datasets. SynthFM-3D training led to consistent and statistically significant Dice score improvements over the pretrained SAM 2 baseline, demonstrating stronger zero-shot generalization across modalities. When compared with the supervised SAM-Med3D model on unseen cardiac ultrasound data, SynthFM-3D achieved 2-3x higher Dice scores, establishing analytical 3D data modeling as an effective pathway to modality-agnostic medical segmentation.

eess.IV

Comparing SAM 2 and SAM 3 for Zero-Shot Segmentation of 3D Medical Data

Foundation models, such as the Segment Anything Model (SAM), have heightened interest in promptable zero-shot segmentation. Although these models perform strongly on natural images, their behavior on medical data remains insufficiently characterized. While SAM 2 has been widely adopted for annotation in 3D medical workflows, the recently released SAM 3 introduces a new architecture that may change how visual prompts are interpreted and propagated. Therefore, to assess whether SAM 3 can serve as an out-of-the-box replacement for SAM 2 for zero-shot segmentation of 3D medical data, we present the first controlled comparison of both models by evaluating SAM 3 in its Promptable Visual Segmentation (PVS) mode using a variety of prompting strategies. We benchmark on 16 public datasets (CT, MRI, Ultrasound, endoscopy) covering 54 anatomical structures, pathologies, and surgical instruments. We further quantify three failure modes: prompt-frame over-segmentation, over-propagation after object disappearance, and temporal retention of well-initialized predictions. Our results show that SAM 3 is consistently stronger under click prompting across modalities, with fewer prompt-frame over-segmentation failures and slower prediction retention decay compared to SAM 2. Under bounding-box and mask prompts, performance gaps narrow in few structures of CT/MR and the models trade off termination behavior, while SAM 3 remains stronger on ultrasound and endoscopy sequences. The overall results position SAM 3 as the superior default choice for most medical segmentation tasks, while clarifying when SAM 2 remains a preferable propagator.

eess.IV

Analysis of the MICCAI Brain Tumor Segmentation -- Metastases (BraTS-METS) 2025 Lighthouse Challenge: Brain Metastasis Segmentation on Pre- and Post-treatment MRI

Despite continuous advancements in cancer treatment, brain metastatic disease remains a significant complication of primary cancer and is associated with an unfavorable prognosis. One approach for improving diagnosis, management, and outcomes is to implement algorithms based on artificial intelligence for the automated segmentation of both pre- and post-treatment MRI brain images. Such algorithms rely on volumetric criteria for lesion identification and treatment response assessment, which are still not available in clinical practice. Therefore, it is critical to establish tools for rapid volumetric segmentations methods that can be translated to clinical practice and that are trained on high quality annotated data. The BraTS-METS 2025 Lighthouse Challenge aims to address this critical need by establishing inter-rater and intra-rater variability in dataset annotation by generating high quality annotated datasets from four individual instances of segmentation by neuroradiologists while being recorded on video (two instances doing "from scratch" and two instances after AI pre-segmentation). This high-quality annotated dataset will be used for testing phase in 2025 Lighthouse challenge and will be publicly released at the completion of the challenge. The 2025 Lighthouse challenge will also release the 2023 and 2024 segmented datasets that were annotated using an established pipeline of pre-segmentation, student annotation, two neuroradiologists checking, and one neuroradiologist finalizing the process. It builds upon its previous edition by including post-treatment cases in the dataset. Using these high-quality annotated datasets, the 2025 Lighthouse challenge plans to test benchmark algorithms for automated segmentation of pre-and post-treatment brain metastases (BM), trained on diverse and multi-institutional datasets of MRI images obtained from patients with brain metastases.

q-bio.OT

SynthFM: Training Modality-agnostic Foundation Models for Medical Image Segmentation without Real Medical Data

Foundation models like the Segment Anything Model (SAM) excel in zero-shot segmentation for natural images but struggle with medical image segmentation due to differences in texture, contrast, and noise. Annotating medical images is costly and requires domain expertise, limiting large-scale annotated data availability. To address this, we propose SynthFM, a synthetic data generation framework that mimics the complexities of medical images, enabling foundation models to adapt without real medical data. Using SAM's pretrained encoder and training the decoder from scratch on SynthFM's dataset, we evaluated our method on 11 anatomical structures across 9 datasets (CT, MRI, and Ultrasound). SynthFM outperformed zero-shot baselines like SAM and MedSAM, achieving superior results under different prompt settings and on out-of-distribution datasets.

eess.IV

QCResUNet: Joint Subject-level and Voxel-level Segmentation Quality Prediction

Deep learning has made significant strides in automated brain tumor segmentation from magnetic resonance imaging (MRI) scans in recent years. However, the reliability of these tools is hampered by the presence of poor-quality segmentation outliers, particularly in out-of-distribution samples, making their implementation in clinical practice difficult. Therefore, there is a need for quality control (QC) to screen the quality of the segmentation results. Although numerous automatic QC methods have been developed for segmentation quality screening, most were designed for cardiac MRI segmentation, which involves a single modality and a single tissue type. Furthermore, most prior works only provided subject-level predictions of segmentation quality and did not identify erroneous parts segmentation that may require refinement. To address these limitations, we proposed a novel multi-task deep learning architecture, termed QCResUNet, which produces subject-level segmentation-quality measures as well as voxel-level segmentation error maps for each available tissue class. To validate the effectiveness of the proposed method, we conducted experiments on assessing its performance on evaluating the quality of two distinct segmentation tasks. First, we aimed to assess the quality of brain tumor segmentation results. For this task, we performed experiments on one internal and two external datasets. Second, we aimed to evaluate the segmentation quality of cardiac Magnetic Resonance Imaging (MRI) data from the Automated Cardiac Diagnosis Challenge. The proposed method achieved high performance in predicting subject-level segmentation-quality metrics and accurately identifying segmentation errors on a voxel basis. This has the potential to be used to guide human-in-the-loop feedback to improve segmentations in clinical settings.

eess.IV

The Brain Tumor Segmentation (BraTS-METS) Challenge 2023: Brain Metastasis Segmentation on Pre-treatment MRI

The translation of AI-generated brain metastases (BM) segmentation into clinical practice relies heavily on diverse, high-quality annotated medical imaging datasets. The BraTS-METS 2023 challenge has gained momentum for testing and benchmarking algorithms using rigorously annotated internationally compiled real-world datasets. This study presents the results of the segmentation challenge and characterizes the challenging cases that impacted the performance of the winning algorithms. Untreated brain metastases on standard anatomic MRI sequences (T1, T2, FLAIR, T1PG) from eight contributed international datasets were annotated in stepwise method: published UNET algorithms, student, neuroradiologist, final approver neuroradiologist. Segmentations were ranked based on lesion-wise Dice and Hausdorff distance (HD95) scores. False positives (FP) and false negatives (FN) were rigorously penalized, receiving a score of 0 for Dice and a fixed penalty of 374 for HD95. Eight datasets comprising 1303 studies were annotated, with 402 studies (3076 lesions) released on Synapse as publicly available datasets to challenge competitors. Additionally, 31 studies (139 lesions) were held out for validation, and 59 studies (218 lesions) were used for testing. Segmentation accuracy was measured as rank across subjects, with the winning team achieving a LesionWise mean score of 7.9. Common errors among the leading teams included false negatives for small lesions and misregistration of masks in space.The BraTS-METS 2023 challenge successfully curated well-annotated, diverse datasets and identified common errors, facilitating the translation of BM segmentation across varied clinical environments and providing personalized volumetric reports to patients undergoing BM treatment.

q-bio.OT

Is SAM 2 Better than SAM in Medical Image Segmentation?

The Segment Anything Model (SAM) has demonstrated impressive performance in zero-shot promptable segmentation on natural images. The recently released Segment Anything Model 2 (SAM 2) claims to outperform SAM on images and extends the model's capabilities to video segmentation. Evaluating the performance of this new model in medical image segmentation, specifically in a zero-shot promptable manner, is crucial. In this work, we conducted extensive studies using multiple datasets from various imaging modalities to compare the performance of SAM and SAM 2. We employed two point-prompt strategies: (i) multiple positive prompts where one prompt is placed near the centroid of the target structure, while the remaining prompts are randomly placed within the structure, and (ii) combined positive and negative prompts where one positive prompt is placed near the centroid of the target structure, and two negative prompts are positioned outside the structure, maximizing the distance from the positive prompt and from each other. The evaluation encompassed 24 unique organ-modality combinations, including abdominal structures, cardiac structures, fetal head images, skin lesions and polyp images across 11 publicly available MRI, CT, ultrasound, dermoscopy, and endoscopy datasets. Preliminary results based on 2D images indicate that while SAM 2 may perform slightly better in a few cases, it does not generally surpass SAM for medical image segmentation. Notably, SAM 2 performs worse than SAM in lower contrast imaging modalities, such as CT and ultrasound. However, for MRI images, SAM 2 performs on par with or better than SAM. Like SAM, SAM 2 also suffers from over-segmentation issues, particularly when the boundaries of the target organ are fuzzy.

eess.IV

Framing image registration as a landmark detection problem for label-noise-aware task representation (HitR)

Accurate image registration is pivotal in biomedical image analysis, where selecting suitable registration algorithms demands careful consideration. While numerous algorithms are available, the evaluation metrics to assess their performance have remained relatively static. This study addresses this challenge by introducing a novel evaluation metric termed Landmark Hit Rate (HitR), which focuses on the clinical relevance of image registration accuracy. Unlike traditional metrics such as Target Registration Error, which emphasize subresolution differences, HitR considers whether registration algorithms successfully position landmarks within defined confidence zones. This paradigm shift acknowledges the inherent annotation noise in medical images, allowing for more meaningful assessments. To equip HitR with label-noise-awareness, we propose defining these confidence zones based on an Inter-rater Variance analysis. Consequently, hit rate curves are computed for varying landmark zone sizes, enabling performance measurement for a task-specific level of accuracy. Our approach offers a more realistic and meaningful assessment of image registration algorithms, reflecting their suitability for clinical and biomedical applications.

eess.IV

The Brain Tumor Sequence Registration (BraTS-Reg) Challenge: Establishing Correspondence Between Pre-Operative and Follow-up MRI Scans of Diffuse Glioma Patients

Registration of longitudinal brain MRI scans containing pathologies is challenging due to dramatic changes in tissue appearance. Although there has been progress in developing general-purpose medical image registration techniques, they have not yet attained the requisite precision and reliability for this task, highlighting its inherent complexity. Here we describe the Brain Tumor Sequence Registration (BraTS-Reg) challenge, as the first public benchmark environment for deformable registration algorithms focusing on estimating correspondences between pre-operative and follow-up scans of the same patient diagnosed with a diffuse brain glioma. The BraTS-Reg data comprise de-identified multi-institutional multi-parametric MRI (mpMRI) scans, curated for size and resolution according to a canonical anatomical template, and divided into training, validation, and testing sets. Clinical experts annotated ground truth (GT) landmark points of anatomical locations distinct across the temporal domain. Quantitative evaluation and ranking were based on the Median Euclidean Error (MEE), Robustness, and the determinant of the Jacobian of the displacement field. The top-ranked methodologies yielded similar performance across all evaluation metrics and shared several methodological commonalities, including pre-alignment, deep neural networks, inverse consistency analysis, and test-time instance optimization per-case basis as a post-processing step. The top-ranked method attained the MEE at or below that of the inter-rater variability for approximately 60% of the evaluated landmarks, underscoring the scope for further accuracy and robustness improvements, especially relative to human experts. The aim of BraTS-Reg is to continue to serve as an active resource for research, with the data and online evaluation tools accessible at https://bratsreg.github.io/.

eess.IV

Primitive Simultaneous Optimization of Similarity Metrics for Image Registration

Even though simultaneous optimization of similarity metrics is a standard procedure in the field of semantic segmentation, surprisingly, this is much less established for image registration. To help closing this gap in the literature, we investigate in a complex multi-modal 3D setting whether simultaneous optimization of registration metrics, here implemented by means of primitive summation, can benefit image registration. We evaluate two challenging datasets containing collections of pre- to post-operative and pre- to intra-operative MR images of glioma. Employing the proposed optimization, we demonstrate improved registration accuracy in terms of TRE on expert neuroradiologists' landmark annotations.

eess.IV

MRI-based classification of IDH mutation and 1p/19q codeletion status of gliomas using a 2.5D hybrid multi-task convolutional neural network

Isocitrate dehydrogenase (IDH) mutation and 1p/19q codeletion status are important prognostic markers for glioma. Currently, they are determined using invasive procedures. Our goal was to develop artificial intelligence-based methods to non-invasively determine these molecular alterations from MRI. For this purpose, pre-operative MRI scans of 2648 patients with gliomas (grade II-IV) were collected from Washington University School of Medicine (WUSM; n = 835) and publicly available datasets viz. Brain Tumor Segmentation (BraTS; n = 378), LGG 1p/19q (n = 159), Ivy Glioblastoma Atlas Project (Ivy GAP; n = 41), The Cancer Genome Atlas (TCGA; n = 461), and the Erasmus Glioma Database (EGD; n = 774). A 2.5D hybrid convolutional neural network was proposed to simultaneously localize the tumor and classify its molecular status by leveraging imaging features from MR scans and prior knowledge features from clinical records and tumor location. The models were tested on one internal (TCGA) and two external (WUSM and EGD) test sets. For IDH, the best-performing model achieved areas under the receiver operating characteristic (AUROC) of 0.925, 0.874, 0.933 and areas under the precision-recall curves (AUPRC) of 0.899, 0.702, 0.853 on the internal, WUSM, and EGD test sets, respectively. For 1p/19q, the best model achieved AUROCs of 0.782, 0.754, 0.842, and AUPRCs of 0.588, 0.713, 0.782, on those three data-splits, respectively. The high accuracy of the model on unseen data showcases its generalization capabilities and suggests its potential to perform a 'virtual biopsy' for tailoring treatment planning and overall clinical management of gliomas.

eess.IV

Integrative Imaging Informatics for Cancer Research: Workflow Automation for Neuro-oncology (I3CR-WANO)

Efforts to utilize growing volumes of clinical imaging data to generate tumor evaluations continue to require significant manual data wrangling owing to the data heterogeneity. Here, we propose an artificial intelligence-based solution for the aggregation and processing of multisequence neuro-oncology MRI data to extract quantitative tumor measurements. Our end-to-end framework i) classifies MRI sequences using an ensemble classifier, ii) preprocesses the data in a reproducible manner, iii) delineates tumor tissue subtypes using convolutional neural networks, and iv) extracts diverse radiomic features. Moreover, it is robust to missing sequences and adopts an expert-in-the-loop approach, where the segmentation results may be manually refined by radiologists. Following the implementation of the framework in Docker containers, it was applied to two retrospective glioma datasets collected from the Washington University School of Medicine (WUSM; n = 384) and the M.D. Anderson Cancer Center (MDA; n = 30) comprising preoperative MRI scans from patients with pathologically confirmed gliomas. The scan-type classifier yielded an accuracy of over 99%, correctly identifying sequences from 380/384 and 30/30 sessions from the WUSM and MDA datasets, respectively. Segmentation performance was quantified using the Dice Similarity Coefficient between the predicted and expert-refined tumor masks. Mean Dice scores were 0.882 ($\pm$0.244) and 0.977 ($\pm$0.04) for whole tumor segmentation for WUSM and MDA, respectively. This streamlined framework automatically curated, processed, and segmented raw MRI data of patients with varying grades of gliomas, enabling the curation of large-scale neuro-oncology datasets and demonstrating a high potential for integration as an assistive tool in clinical practice.

eess.IV