SearcharxivSearch

arXiv subjects

Saurabh Malhotra

Publications and source records attributed to Saurabh Malhotra.

2 recordsLinked to original sources

Artificial Intelligence Across the Cardiac Amyloidosis Diagnostic Pathway: From Single-Modality Detection to Multimodal Clinical Integration

Cardiac amyloidosis (CA) is increasingly recognized but remains substantially underdiagnosed, because its clinical and imaging phenotype overlaps with more common cardiomyopathies. Definitive subtype assignment and management further require integration of multimodal evidence to distinguish transthyretin from light chain disease. Machine learning and deep learning have been applied across the diagnostic and management pathway. These applications span ECG, echocardiography, and health record-based case finding, as well as CMR and nuclear interpretation, including SPECT/CT biomarker quantification, prognostic modeling, and treatment response assessment. This narrative review synthesizes these studies by clinical tasks, namely screening, detection, quantification, prognosis, and treatment response monitoring, rather than by input modality. This task-based organization clarifies why apparently similar AI models require different cohorts, reference standards, evaluation metrics, and implementation thresholds. The evidence reveals a maturity gradient. Binary detection and AI assisted quantification on bone scintigraphy and SPECT/CT are closest to clinical translation. Detection is supported by large externally validated cohorts, and quantification by interpretable, outcome linked measurement of myocardial tracer burden. By contrast, subtype aware classification, prognostic risk stratification, and treatment response monitoring remain at an early stage. These tasks are limited by small cohorts, enriched retrospective designs, heterogeneous labels, incomplete external validation, and uncertain calibration in realistic prevalence settings. Across tasks, high discrimination alone is insufficient.

physics.med-ph

Automatic reorientation by deep learning to generate short axis SPECT myocardial perfusion images

Single photon emission computed tomography (SPECT) myocardial perfusion images (MPI) can be displayed both in traditional short-axis (SA) cardiac planes and polar maps for interpretation and quantification. It is essential to reorient the reconstructed transaxial SPECT MPI into standard SA slices. This study is aimed to develop a deep-learning-based approach for automatic reorientation of MPI. Methods: A total of 254 patients were enrolled, including 228 stress SPECT MPIs and 248 rest SPECT MPIs. Five-fold cross-validation with 180 stress and 201 rest MPIs was used for training and internal validation; the remaining images were used for testing. The rigid transformation parameters (translation and rotation) from manual reorientation were annotated by an experienced operator and used as the ground truth. A convolutional neural network (CNN) was designed to predict the transformation parameters. Then, the derived transform was applied to the grid generator and sampler in spatial transformer network (STN) to generate the reoriented image. A loss function containing mean absolute errors for translation and mean square errors for rotation was employed. A three-stage optimization strategy was adopted for model optimization: 1) optimize the translation parameters while fixing the rotation parameters; 2) optimize rotation parameters while fixing the translation parameters; 3) optimize both translation and rotation parameters together.

eess.IV