SearcharxivSearch

arXiv subjects

Sayuri Takatori

Publications and source records attributed to Sayuri Takatori.

12 recordsLinked to original sources

Analytical study of birefringent cavities for axion-like dark matter search

Light polarization plays a crucial role in optical-cavity experiments; however, mirror birefringence presents a significant challenge that must be addressed carefully. In this study, a rigorous, nonperturbative framework is developed to quantify birefringence effects by incorporating variations in reflectance and polarization misalignment. We analyze the impact of this framework on the sensitivity of axion-like particle (ALP) dark-matter searches. The results show that both birefringence and misalignment contribute to sensitivity degradation in the low-mass regime; however, the adverse effects of misalignment can be mitigated by selecting a postselection angle greater than the misalignment angle. Furthermore, birefringence produces an additional resonance peak in the high-mass region, which remains largely unaffected by misalignment and postselection variations. This rigorous framework underscores the importance of considering birefringence in high-precision optical-cavity experiments for ALP detection.

hep-ph

Constraints on the polarization angle oscillations of the Crab Nebula with the Simons Array and its applications to the search for axion-like particles

We present a search for polarization oscillation of the Crab Nebula, also known as Tau A, at millimeter wavelengths using observations with the Simons Array, the successor experiment to POLARBEAR. We follow up on previous work by POLARBEAR using 90 GHz band data of the 2023 observing season of the Simons Array to evaluate the variability of Tau A's polarization angle. Tau A is widely used as a polarization angle calibration source in millimeter-wave astronomy, and thus it is necessary to validate the stability. Additionally, an interesting application of the time-resolved polarimetry of Tau A is to search for axion-like particles (ALPs). We do not detect a global signal across the frequencies considered in this analysis and place a median 95% upper bound of polarization oscillation amplitude $A<0.12^{\circ}$ over oscillation frequencies from 3.39 year$^{-1}$ to 1.50 day$^{-1}$. This constrains the ALP-photon coupling at a median 95% upper bound of $g_{aγγ}< 3.84\times 10^{-12}\times\left(m_a/10^{-21}\,\mathrm{eV}\right)$ in the mass range from $4.4\times10^{-22}$ to $7.2\times10^{-20}$ eV, assuming the ALP constitutes all of dark matter, its field is a stochastic Gaussian field, and it is the sole source of Tau A's polarization angle oscillation. Additionally, we do not detect signal at the frequencies where 2.5$σ$ hints were previously reported by POLARBEAR, but we do not exclude these signals at the 95% confidence level.

astro-ph.CO

Laser M\"ossbauer spectroscopy of ^{229}Th

M\"ossbauer spectroscopy is widely used in biochemistry, geology, and solid-state physics to obtain structural information on materials. Here, we extend this technique into the optical range using a vacuum ultraviolet laser to probe the low-energy nuclear transitions of thorium-229, doped in calcium fluoride crystals. We discover four distinct doping sites for the thorium ions, determine the characteristic electric field gradients emerging in the interaction with the host crystal, and identify the microscopic structure of the two dominant configurations. Site-selective laser excitation allows to study the isomeric state lifetime and laser-induced quenching for all sites. This laser-based M\"ossbauer spectroscopy provides a powerful probe of the nuclear environment, yielding foundational data for designing future solid-state nuclear clocks.

nucl-ex

X-ray-induced quenching of the $^{229}$Th clock isomer in CaF$_2$

Thorium-229 has the lowest nuclear-excited state (an isomer state) at approximately 8.356 eV, making it excitable with tabletop vacuum-ultraviolet lasers. Despite the recent success of laser excitation, the isomer quenching inside the solid-state environment remains unresolved. In this letter, we present experiments investigating X-ray-induced isomer quenching in the CaF$_2$ host, focusing on the effects of X-ray flux and temperature on the lifetime and yield of the isomer state. Our studies reveal a correlation between isomer production, isomer lifetime during irradiation, and post-irradiation afterglow of the target crystal across different temperatures, highlighting a strong relationship between isomer quenching and color-center dynamics. We developed a model to interpret the isomer quenching and the crystal's luminescence.

cond-mat.mtrl-sci

A method to detect the VUV photons from cooled $^{229}$Th:CaF$_2$ crystals

Thorium-229, with its exceptionally low-energy nuclear excited state, is a key candidate for developing nuclear clocks. $^{229}$Th-doped CaF$_2$ crystals, benefiting from calcium fluoride's wide band gap, show great promise as solid-state nuclear clock materials. These crystals are excited by vacuum ultraviolet (VUV) lasers, which over time cause radiation damage. Cooling the crystals can mitigate this damage but introduces a challenge: photoabsorption. This occurs when residual gas molecules condense on the crystal surface, absorbing VUV photons and deteriorating detection efficiency. To solve this, we developed a cooling technique using a copper shield to surround the crystal, acting as a cold trap. This prevents ice-layer formation, even at temperatures below $-100\,^\circ$C, preserving high VUV photon detection efficiency. Our study detailed the experimental cooling setup and demonstrated the effectiveness of the copper shield in maintaining crystal performance, a critical improvement for future solid-state nuclear clocks operating at cryogenic temperatures.

physics.ins-det

Controlling $^{229}$Th isomeric state population in a VUV transparent crystal

The radioisotope Th-229 is renowned for its extraordinarily low-energy, long-lived nuclear first-excited state. This isomeric state can be excited by VUV lasers and the transition from the ground state has been proposed as a reference transition for ultra-precise nuclear clocks. Such nuclear clocks will find multiple applications, ranging from fundamental physics studies to practical implementations. Recent investigations extracted valuable constraints on the nuclear transition energy and lifetime, populating the isomer in stochastic nuclear decay of U-233 or Ac-229. However, to assess the feasibility and performance of the (solid-state) nuclear clock concept, time-controlled excitation and depopulation of the $^{229}$Th isomer together with time-resolved monitoring of the radiative decay are imperative. Here we report the population of the $^{229}$Th isomeric state through resonant X-ray pumping and detection of the radiative decay in a VUV transparent $^{229}$Th-doped CaF$_2$ crystal. The decay half-life is measured to $447\pm 25$ s, with a transition wavelength of $148.18 \pm 0.42$ nm and a radiative decay fraction consistent with unity. Furthermore, we report a new ``X-ray quenching'' effect which allows to de-populate the isomer on demand and effectively reduce the half-life by at least a factor 50. Such controlled quenching can be used to significantly speed up the interrogation cycle in future nuclear clock schemes. Our results show that full control over the $^{229}$Th nuclear isomer population can be achieved in a crystal environment. In particular, non-radiative decay processes that might lead to a broadening of the isomer transition linewidth are negligible, paving the way for the development of a compact and robust solid-state nuclear clock. Further studies are needed to reveal the underlying physical mechanism of the X-ray quenching effect.

nucl-ex

Constraints on axion-like polarization oscillations in the cosmic microwave background with POLARBEAR

Very light pseudoscalar fields, often referred to as axions, are compelling dark matter candidates and can potentially be detected through their coupling to the electromagnetic field. Recently a novel detection technique using the cosmic microwave background (CMB) was proposed, which relies on the fact that the axion field oscillates at a frequency equal to its mass in appropriate units, leading to a time-dependent birefringence. For appropriate oscillation periods this allows the axion field at the telescope to be detected via the induced sinusoidal oscillation of the CMB linear polarization. We search for this effect in two years of POLARBEAR data. We do not detect a signal, and place a median $95 \%$ upper limit of $0.65 ^\circ$ on the sinusoid amplitude for oscillation frequencies between $0.02\,\text{days}^{-1}$ and $0.45\,\text{days}^{-1}$, which corresponds to axion masses between $9.6 \times 10^{-22} \, \text{eV}$ and $2.2\times 10^{-20} \,\text{eV}$. Under the assumptions that 1) the axion constitutes all the dark matter and 2) the axion field amplitude is a Rayleigh-distributed stochastic variable, this translates to a limit on the axion-photon coupling $g_{ϕγ} < 2.4 \times 10^{-11} \,\text{GeV}^{-1} \times ({m_ϕ}/{10^{-21} \, \text{eV}})$.

astro-ph.CO

Measurement of the Cosmic Microwave Background Polarization Lensing Power Spectrum from Two Years of POLARBEAR Data

We present a measurement of the gravitational lensing deflection power spectrum reconstructed with two seasons cosmic microwave background polarization data from the POLARBEAR experiment. Observations were taken at 150 GHz from 2012 to 2014 which survey three patches of sky totaling 30 square degrees. We test the consistency of the lensing spectrum with a Cold Dark Matter (CDM) cosmology and reject the no-lensing hypothesis at a confidence of 10.9 sigma including statistical and systematic uncertainties. We observe a value of A_L = 1.33 +/- 0.32 (statistical) +/- 0.02 (systematic) +/- 0.07 (foreground) using all polarization lensing estimators, which corresponds to a 24% accurate measurement of the lensing amplitude. Compared to the analysis of the first year data, we have improved the breadth of both the suite of null tests and the error terms included in the estimation of systematic contamination.

astro-ph.CO

The POLARBEAR Fourier Transform Spectrometer Calibrator and Spectroscopic Characterization of the POLARBEAR Instrument

We describe the Fourier Transform Spectrometer (FTS) used for in-field testing of the POLARBEAR receiver, an experiment located in the Atacama Desert of Chile which measures the cosmic microwave background (CMB) polarization. The POLARBEAR-FTS (PB-FTS) is a Martin-Puplett interferometer designed to couple to the Huan Tran Telescope (HTT) on which the POLARBEAR receiver is installed. The PB-FTS measured the spectral response of the POLARBEAR receiver with signal-to-noise ratio (SNR) $>20$ for $\sim$69% of the focal plane detectors due to three features: a high throughput of 15.1 steradian cm$^{2}$, optimized optical coupling to the POLARBEAR optics using a custom designed output parabolic mirror, and a continuously modulated output polarizer. The PB-FTS parabolic mirror is designed to mimic the shape of the 2.5 m-diameter HTT primary reflector which allows for optimum optical coupling to the POLARBEAR receiver, reducing aberrations and systematics. One polarizing grid is placed at the output of the PB-FTS, and modulated via continuous rotation. This modulation allows for decomposition of the signal into different harmonics that can be used to probe potentially pernicious sources of systematic error in a polarization-sensitive instrument. The high throughput and continuous output polarizer modulation features are unique compared to other FTS calibrators used in the CMB field. In-field characterization of the POLARBEAR receiver was accomplished using the PB-FTS in April 2014. We discuss the design, construction, and operation of the PB-FTS and present the spectral characterization of the POLARBEAR receiver. We introduce future applications for the PB-FTS in the next-generation CMB experiment, the Simons Array.

astro-ph.IM

Evidence for the Cross-correlation between Cosmic Microwave Background Polarization Lensing from POLARBEAR and Cosmic Shear from Subaru Hyper Suprime-Cam

We present the first measurement of cross-correlation between the lensing potential, reconstructed from cosmic microwave background (CMB) {\it polarization} data, and the cosmic shear field from galaxy shapes. This measurement is made using data from the POLARBEAR CMB experiment and the Subaru Hyper Suprime-Cam (HSC) survey. By analyzing an 11~deg$^2$ overlapping region, we reject the null hypothesis at 3.5$σ$\ and constrain the amplitude of the {\bf cross-spectrum} to $\widehat{A}_{\rm lens}=1.70\pm 0.48$, where $\widehat{A}_{\rm lens}$ is the amplitude normalized with respect to the Planck~2018{} prediction, based on the flat $Λ$ cold dark matter cosmology. The first measurement of this {\bf cross-spectrum} without relying on CMB temperature measurements is possible due to the deep POLARBEAR map with a noise level of ${\sim}$6\,$μ$K-arcmin, as well as the deep HSC data with a high galaxy number density of $n_g=23\,{\rm arcmin^{-2}}$. We present a detailed study of the systematics budget to show that residual systematics in our results are negligibly small, which demonstrates the future potential of this cross-correlation technique.

astro-ph.CO

Measurements of tropospheric ice clouds with a ground-based CMB polarization experiment, POLARBEAR

The polarization of the atmosphere has been a long-standing concern for ground-based experiments targeting cosmic microwave background (CMB) polarization. Ice crystals in upper tropospheric clouds scatter thermal radiation from the ground and produce a horizontally-polarized signal. We report the detailed analysis of the cloud signal using a ground-based CMB experiment, POLARBEAR, located at the Atacama desert in Chile and observing at 150 GHz. We observe horizontally-polarized temporal increases of low-frequency fluctuations ("polarized bursts," hereafter) of $\lesssim$0.1 K when clouds appear in a webcam monitoring the telescope and the sky. The hypothesis of no correlation between polarized bursts and clouds is rejected with $>$24$σ$ statistical significance using three years of data. We consider many other possibilities including instrumental and environmental effects, and find no other reasons other than clouds that can explain the data better. We also discuss the impact of the cloud polarization on future ground-based CMB polarization experiments.

astro-ph.IM

Performance of a continuously rotating half-wave plate on the POLARBEAR telescope

A continuously rotating half-wave plate (CRHWP) is a promising tool to improve the sensitivity to large angular scales in cosmic microwave background (CMB) polarization measurements. With a CRHWP, single detectors can measure three of the Stokes parameters, $I$, $Q$ and $U$, thereby avoiding the set of systematic errors that can be introduced by mismatches in the properties of orthogonal detector pairs. We focus on the implementation of CRHWPs in large aperture telescopes (i.e. the primary mirror is larger than the current maximum half-wave plate diameter of $\sim$0.5 m), where the CRHWP can be placed between the primary mirror and focal plane. In this configuration, one needs to address the intensity to polarization ($I{\rightarrow}P$) leakage of the optics, which becomes a source of 1/f noise and also causes differential gain systematics that arise from CMB temperature fluctuations. In this paper, we present the performance of a CRHWP installed in the POLARBEAR experiment, which employs a Gregorian telescope with a 2.5 m primary illumination pattern. The CRHWP is placed near the prime focus between the primary and secondary mirrors. We find that the $I{\rightarrow}P$ leakage is larger than the expectation from the physical properties of our primary mirror, resulting in a 1/f knee of 100 mHz. The excess leakage could be due to imperfections in the detector system, i.e. detector non-linearity in the responsivity and time-constant. We demonstrate, however, that by subtracting the leakage correlated with the intensity signal, the 1/f noise knee frequency is reduced to 32 mHz ($\ell \sim$39 for our scan strategy), which is very promising to probe the primordial B-mode signal. We also discuss methods for further noise subtraction in future projects where the precise temperature control of instrumental components and the leakage reduction will play a key role.

astro-ph.IM